EXPERIENCES IN DEVELOPING AN AUTOMATED FACTOR-JUMP METHOD OF THERMOGRAVIMETRY

被引:7
作者
DICKENS, B
机构
[1] Center for Materials Research, National Bureau of Standards, Washington
关键词
D O I
10.1016/0040-6031(79)85021-2
中图分类号
O414.1 [热力学];
学科分类号
摘要
We have recently provided details of an apparatus and computer programs to implement the factor-jump method of thermogravimetry. This paper describes the refinement of the technique to the present status of quasi-automatic routine operation. The procedure was worked out using samples of polymethyl-methacrylate, polystyrene and polyurethane polymers. The activation energies obtained are measured to 0.2 kcal mole-1 in favorable cases. This is adequate for diagnosis of changes in mechanism but may sometimes be inadequate for scaling temperature accelerated tests to room temperature. © 1979.
引用
收藏
页码:87 / 113
页数:27
相关论文
共 7 条
[1]  
BEVINGTON PR, 1969, DATA REDUCTION ERROR, pCH10
[2]   COMPUTER-PROGRAM TO IMPLEMENT AUTOMATED FACTOR-JUMP THERMOGRAVIMETRY [J].
DICKENS, B .
THERMOCHIMICA ACTA, 1979, 29 (01) :57-85
[3]   AUTOMATION OF FACTOR-JUMP THERMOGRAVIMETRY FOR ACTIVE COMPUTER CONTROL [J].
DICKENS, B .
THERMOCHIMICA ACTA, 1979, 29 (01) :41-56
[4]  
DICKENS B, 1976, 1ST P EUR S THERM AN, P15
[5]  
DICKENS B, 1977, ANAL PYROLYSIS, P383
[6]   STEADY-STATE PARAMETER-JUMP METHODS AND RELAXATION METHODS IN THERMOGRAVIMETRY [J].
FLYNN, JH ;
DICKENS, B .
THERMOCHIMICA ACTA, 1976, 15 (01) :1-16
[7]  
POWELL RL, 1974, NBS125 MON