Analysis of Set-up Errors during CT-scan, Simulation, and Treatment Process in Breast Cancer Patients

被引:0
作者
Lee, Rena [1 ]
机构
[1] Ewha Womans Univ Mokdong Hosp, Coll Med, Dept Radiat Oncol, 911-1 Mok Dong, Seoul, South Korea
来源
RADIATION ONCOLOGY JOURNAL | 2005年 / 23卷 / 03期
关键词
Breast cancer; Setup error;
D O I
暂无
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: Although computed tomography (CT) simulators are commonly used in radiation therapy department, many institution still use conventional CT for treatments. In this study the setup errors that occur during simulation, CT scan (diagnostic CT scanner), and treatment were evaluated for the twenty one breast cancer patients. Materials and Methods: Errors were determined by calculating the differences in isocenter location, SSD, CLD, and locations of surgical clips implanted during surgery. The anatomic structures on simulation film and DRR image were compared to determine the movement of isocenter between simulation and CT scan. The isocetner point determined from the radio-opaque wires placed on patient's surface during CT scan was moved to new position if there was anatomic mismatch between the two images. Results: In 7/21 patients, anatomic structures on DRR image were different from the simulation image thus new isocenter points were placed for treatment planning. The standard deviations of the diagnostic CT setup errors relative to the simulator setup in lateral, longitudinal, and anterior-posterior directions were 2.3, 1.6, and 1.6 mm, respectively. The average variation and standard deviation of SSD from AP field were 1.9 mm and 2.3 mm and from tangential fields were 2.8 mm and 3.7 mm. The variation of the CLD for the 21 patients ranged from 0 to 6 mm between simulation and DRR and 0 to 5 mm between simulation and treatment. The group systematic errors analyzed based on clip locations were 1.7 mm in lateral direction, 2.1 mm in AP direction, and 1.7 mm in SI direction. Conclusion: These results represent that there was no significant differences when SSD, CLD, clips' locations and isocenter locations were considered. Therefore, it is concluded that when a diagnostic CT scanner is used to acquire an image, the set-up variation is acceptable compared to using CT simulator for the treatment of breast cancer. However, the patient has to be positioned with care during CT scan in order to reduce the setup error between simulation and CT scan.
引用
收藏
页码:169 / 175
页数:7
相关论文
共 18 条
[1]   Portal imaging for evaluation of daily on-line setup errors and off-line organ motion during conformal irradiation of carcinoma of the prostate [J].
Alasti, H ;
Petric, MP ;
Catton, CN ;
Warde, PR .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2001, 49 (03) :869-884
[2]  
[Anonymous], 1995, 62 ICRU
[3]   Adequate margins for random setup uncertainties in head-and-neck IMRT [J].
Astreinidou, E ;
Bel, A ;
Raaijmakers, CPJ ;
Terhaard, CHJ ;
Lagendijk, JJW .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 61 (03) :938-944
[4]   Uncertainties in CT-based radiation therapy treatment planning associated with patient breathing [J].
Balter, JM ;
TenHaken, RK ;
Lawrence, TS ;
Lam, KL ;
Robertson, JM .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1996, 36 (01) :167-174
[5]   MAXIMIZING SETUP ACCURACY USING PORTAL IMAGES AS APPLIED TO A CONFORMAL BOOST TECHNIQUE FOR PROSTATIC-CANCER [J].
BIJHOLD, J ;
LEBESQUE, JV ;
HART, AAM ;
VIJLBRIEF, RE .
RADIOTHERAPY AND ONCOLOGY, 1992, 24 (04) :261-271
[6]   Analysis and reduction of 3D systematic and random setup errors during the simulation and treatment of lung cancer patients with CT-based external beam radiotherapy dose planning [J].
de Boer, HCJ ;
De Koste, JRV ;
Senan, S ;
Visser, AG ;
Heijmen, BJM .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2001, 49 (03) :857-868
[7]   Intra- and interfractional reproducibility of tangential breast fields: A prospective on-line portal imaging study [J].
Fein, DA ;
McGee, KP ;
Schultheiss, TE ;
Fowble, BL ;
Hanks, GE .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1996, 34 (03) :733-740
[8]   Conformal radiotherapy (CRT) planning for lung cancer: Analysis of intrathoracic organ motion during extreme phases of breathing [J].
Giraud, P ;
De Rycke, Y ;
Dubray, B ;
Helfre, S ;
Voican, D ;
Guo, L ;
Rosenwald, JC ;
Keraudy, K ;
Housset, M ;
Touboul, E ;
Cosset, JM .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2001, 51 (04) :1081-1092
[9]   Measurement of patient positioning errors in three-dimensional conformal radiotherapy of the prostate [J].
Hanley, J ;
Lumley, MA ;
Mageras, GS ;
Sun, J ;
Zelefsky, MJ ;
Leibel, SA ;
Fuks, Z ;
Kutcher, GJ .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1997, 37 (02) :435-444
[10]   Setup errors in patients treated with intensity-modulated whole pelvic radiation therapy for gynecological malignancies [J].
Haslam, JJ ;
Lujan, AE ;
Mundt, AJ ;
Bonta, DV ;
Roeske, JC .
MEDICAL DOSIMETRY, 2005, 30 (01) :36-42