BIOIMPEDANCE MONITORING OF REHYDRATION IN CHOLERA

被引:33
作者
MCDONALD, JJ
CHANDUVI, B
VELARDE, G
CAMA, R
DIAZ, F
CARRILLO, L
TORRE, V
WATANABE, J
VILLARREAL, J
RAMIREZRAMOS, A
MANTLE, R
GILMAN, RH
机构
[1] JOHNS HOPKINS UNIV,615 N WOLFE ST,BALTIMORE,MD 21205
[2] LOAYZA HOSP,LIMA,PERU
[3] AB PRISMA,LIMA,PERU
[4] UNIV CALIF DAVIS,DAVIS,CA 95616
[5] UNIV VIRGINIA,CHARLOTTESVILLE,VA 22908
[6] NYU,NEW YORK,NY 10003
基金
英国惠康基金;
关键词
D O I
10.1016/0140-6736(93)92410-U
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Measurement of bioimpedance (BI) is a simple non-invasive technique that relies on the different conductivity of tissues to define body composition and can be easily adapted to automated monitoring. We assessed the accuracy of BI in monitoring rehydration and acute fluid fluxes in 35 Peruvian cholera patients. Patients were monitored throughout the acute phase of diarrhoea and followed up at 3 and 10 days. BI was compared with other objective measures of dehydration including packed cell volume, serum protein, and calculated fluid balance. BI rapidly detected inadequate treatment and acute fluid flux, correlating highly with intravascular hydration as measured by serum protein and packed cell volume. BI values during dehydration were significantly raised compared with 10-day convalescent values and age-matched controls (p<0.05). We also encountered an unexpected difference in the bioelectrical response to dehydration and rehydration between sexes. We conclude that BI has uses in monitoring dehydrated patients, in oral rehydration trials, and in physiological studies.
引用
收藏
页码:1049 / 1051
页数:3
相关论文
共 6 条
[1]   ASSESSMENT OF BODY-COMPOSITION BY BIOELECTRICAL IMPEDANCE IN A POPULATION AGED GREATER-THAN-60-Y [J].
DEURENBERG, P ;
VANDERKOOIJ, K ;
EVERS, P ;
HULSHOF, T .
AMERICAN JOURNAL OF CLINICAL NUTRITION, 1990, 51 (01) :3-6
[2]   ASSESSMENT OF FAT-FREE MASS USING BIOELECTRICAL IMPEDANCE MEASUREMENTS OF THE HUMAN-BODY [J].
LUKASKI, HC ;
JOHNSON, PE ;
BOLONCHUK, WW ;
LYKKEN, GI .
AMERICAN JOURNAL OF CLINICAL NUTRITION, 1985, 41 (04) :810-817
[3]   PERIOPERATIVE MONITORING OF TOTAL-BODY WATER BY BIOELECTRICAL IMPEDANCE IN CHILDREN UNDERGOING OPEN-HEART-SURGERY [J].
MAEHARA, T ;
NOVAK, I ;
WYSE, RKH ;
ELLIOT, MJ .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 1991, 5 (05) :258-265
[4]   MEASUREMENT OF CARDIAC-OUTPUT IN PREGNANCY BY THORACIC ELECTRICAL BIOIMPEDANCE AND THERMODILUTION - A PRELIMINARY-REPORT [J].
MASAKI, DI ;
GREENSPOON, JS ;
OUZOUNIAN, JG .
AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1989, 161 (03) :680-684
[5]   ALTERATIONS IN BODY-FLUID CONTENT CAN BE DETECTED BY BIOELECTRICAL IMPEDANCE ANALYSIS [J].
SCHELTINGA, MR ;
JACOBS, DO ;
KIMBROUGH, TD ;
WILMORE, DW .
JOURNAL OF SURGICAL RESEARCH, 1991, 50 (05) :461-468