TEMPERATURE-CHANGE IN THE PULP CHAMBER DURING COMPLETE CROWN PREPARATION

被引:26
作者
LAFORGIA, PD
MILANO, V
MOREA, C
DESIATE, A
机构
关键词
D O I
10.1016/0022-3913(91)90048-2
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
This study observed the temperature changes in the pulp chamber during tooth preparation for a complete crown. Twelve extracted, morphologically intact human teeth were chosen: four canines, four premolars, and four molars. Six teeth, two of each, were cooled during preparation with an air-water spray; the remaining six were air-cooled. Minimal reduction of dentin using an air-water spray coolant resulted in a lowered temperature in the pulp chamber, mainly with the cross-grooved TDA diamond stones. The application of an air coolant resulted in a temperature rise in the pulp chamber.
引用
收藏
页码:56 / 61
页数:6
相关论文
共 21 条
[1]   TEMPERATURE-CHANGE CAUSED BY REDUCING PINS IN DENTIN [J].
BARKMEIER, WW ;
COOLEY, RL .
JOURNAL OF PROSTHETIC DENTISTRY, 1979, 41 (06) :630-633
[2]  
BELKHIR MS, 1986, EMC, P3
[3]  
BHASKAR SN, 1956, J DENT RES, V44, P644
[4]   HEAT CONDUCTION IN TEETH + EFFECT OF LINING MATERIALS [J].
BRADEN, M .
JOURNAL OF DENTAL RESEARCH, 1964, 43 (03) :315-&
[5]  
BRANNSTROM MARTIN, 1960, ACTA ODONTOL SCAND, V18, P1, DOI 10.3109/00016356009026089
[6]  
BRANNSTROM MARTIN, 1960, ACTA ODONTOL SCAND, V18, P235, DOI 10.3109/00016356009003010
[7]  
BRANNSTROM MARTIN, 1960, ACTA ODONTOL SCAND, V18, P17
[8]   THERMOGRAPHIC STUDY OF HEAT DISTRIBUTION DURING ULTRA-SPEED CAVITY PREPARATION [J].
CARSON, J ;
RIDER, T ;
NASH, D .
JOURNAL OF DENTAL RESEARCH, 1979, 58 (07) :1681-1684
[9]   PULPAL EFFECTS OF WATER AND AIR COOLANTS USED IN HIGH-SPEED CAVITY PREPARATIONS [J].
DACHI, SF ;
STIGERS, RW .
JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 1968, 76 (01) :95-&
[10]  