ANISOTROPIC DIFFUSION IN HUMAN WHITE MATTER - DEMONSTRATION WITH MR TECHNIQUES INVIVO

被引:374
作者
CHENEVERT, TL
BRUNBERG, JA
PIPE, JG
机构
[1] Department of Radiology, Univ. of Michigan Medical Center, Ann Arbor, MI 48109-0030
关键词
Brain; MR studies; 10.1214; perfusion; white matter; Magnetic resonance (MR); experimental; technology;
D O I
10.1148/radiology.177.2.2217776
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Quantitative measurements of perfusion and molecular diffusion were made in human white matter in two orientations of the motion-sensitization gradient to document anisotropy of these parameters. Measurements were localized to a 10 × 10-mm tissue column oriented in an anterior-to-posterior direction in the left cerebral hemisphere just above the body of the left ventricle. This region was selected because of the relatively high directionality of white matter fibers. In this study of five healthy volunteers, strong diffusion anisotropy was observed in all cases. Twofold or greater anisotropy was commonly observed, with the higher diffusion value associated with motion sensitivity along the fiber directions. By combining data from both gradient orientations in all cases, diffusion values of solid tissue ranged from 0.38 × 10-3 mm2/ sec to 1.12 × 10-3 mm2/sec, and measured perfusion fractions were in the range of 2%-5% (excluding areas highly contaminated by cerebrospinal fluid). Little or no perfusion-fraction anisotropy was observed; however, perfusion measurements were limited by noise. Data were collected without cardiac gating by using a technique that offers good immunity to bulk tissue motion artifacts.
引用
收藏
页码:401 / 405
页数:5
相关论文
共 20 条
  • [1] CHENEVERT TL, IN PRESS MAGN RESON
  • [2] NUCLEAR MAGNETIC-RESONANCE MEASUREMENT OF SKELETAL-MUSCLE - ANISOTROPY OF DIFFUSION-COEFFICIENT OF INTRACELLULAR WATER
    CLEVELAND, GG
    CHANG, DC
    HAZLEWOOD, CF
    RORSCHACH, HE
    [J]. BIOPHYSICAL JOURNAL, 1976, 16 (09) : 1043 - 1053
  • [3] RESTRICTED DIFFUSION IN BIOPHYSICAL SYSTEMS - EXPERIMENT
    COOPER, RL
    CHANG, DB
    YOUNG, AC
    MARTIN, CJ
    ANCKERJO.B
    [J]. BIOPHYSICAL JOURNAL, 1974, 14 (03) : 161 - 177
  • [4] CROSBY EC, 1962, CORRELATIVE ANATOMY, P394
  • [5] HUMAN-BRAIN MOTION AND CEREBROSPINAL-FLUID CIRCULATION DEMONSTRATED WITH MR VELOCITY IMAGING
    FEINBERG, DA
    MARK, AS
    [J]. RADIOLOGY, 1987, 163 (03) : 793 - 799
  • [6] INTRAVOXEL INCOHERENT MOTION IMAGING USING STEADY-STATE FREE PRECESSION
    LEBIHAN, D
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1988, 7 (03) : 346 - 351
  • [7] SEPARATION OF DIFFUSION AND PERFUSION IN INTRAVOXEL INCOHERENT MOTION MR IMAGING
    LEBIHAN, D
    BRETON, E
    LALLEMAND, D
    AUBIN, ML
    VIGNAUD, J
    LAVALJEANTET, M
    [J]. RADIOLOGY, 1988, 168 (02) : 497 - 505
  • [8] SELF-DIFFUSION NMR IMAGING USING STIMULATED ECHOES
    MERBOLDT, KD
    HANICKE, W
    FRAHM, J
    [J]. JOURNAL OF MAGNETIC RESONANCE, 1985, 64 (03) : 479 - 486
  • [9] THE INFLUENCE OF FLOW AND MOTION IN MRI OF DIFFUSION USING A MODIFIED CE-FAST SEQUENCE
    MERBOLDT, KD
    HANICKE, W
    GYNGELL, ML
    FRAHM, J
    BRUHN, H
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1989, 12 (02) : 198 - 208
  • [10] MRI OF DIFFUSION IN THE HUMAN-BRAIN - NEW RESULTS USING A MODIFIED CE-FAST SEQUENCE
    MERBOLDT, KD
    BRUHN, H
    FRAHM, J
    GYNGELL, ML
    HANICKE, W
    DEIMLING, M
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1989, 9 (03) : 423 - 429