ELECTROCHEMICAL OXYGEN SENSOR FOR MEASUREMENT OF OXYGEN IN LIQUID-SODIUM

被引:17
作者
ROY, P
BUGBEE, BE
机构
[1] Gen. Electric Comp., Fast Breeder Reactor Dept., San Jose, Calif. 95125, United States
关键词
LIQUID METALS;
D O I
10.13182/NT78-A32081
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The results obtained from similar 4000 h of operation of an electrochemical oxygen meter developed at General Electric Company for measuring oxygen activities in liquid sodium are described. In the present design, a small ceramic cup (ThO//2 with 7 to 8 wt% Y//2O//3) has been brazed to a metal tube that is inserted into the liquid sodium via a standard sodium flange. The reference electrode used in the present design consists of In/In//2O//3. Several meters were tested in a flowing sodium system, where the oxygen concentrations were controlled by a cold trap.
引用
收藏
页码:216 / 218
页数:3
相关论文
共 9 条
[1]  
BERKEY E, 1975, METAL SLAG GAS REACT, P921
[2]  
CLAXTON KT, 1976, P INT C LIQUID METAL, P407
[3]  
EICHELBERGER RT, 1968, AIAEC12685 AT INT
[4]   OXYGEN DETERMINATION IN LIQUID-SODIUM WITH INDUSTRIAL ELECTROCHEMICAL MEASURING PROBE [J].
JUNG, J .
JOURNAL OF NUCLEAR MATERIALS, 1975, 56 (02) :213-220
[5]   CALIBRATION STABILITY OF OXYGEN METERS FOR LMFBR SODIUM SYSTEMS [J].
MCKEE, JM ;
VISSERS, DR ;
NELSON, PA ;
GRUNDY, BR ;
BERKEY, E ;
TAYLOR, GR .
NUCLEAR TECHNOLOGY, 1974, 21 (03) :217-227
[6]  
MEYERS JE, 1968, P INT C SODIUM TEC 1, P233
[7]  
Roy P., 1976, P INT C LIQ MET TECH, P541
[8]  
SMITH DL, 1972, ANL7871, P3
[9]  