PERCUTANEOUS INDWELLING RADIAL-ARTERY CATHETERS FOR MONITORING CARDIOVASCULAR FUNCTION - PROSPECTIVE STUDY OF RISK OF THROMBOSIS AND INFECTION

被引:117
作者
GARDNER, RM
SCHWARTZ, R
WONG, HC
BURKE, JP
机构
[1] LATTER DAY STS HOSP,SALT LAKE CITY,UT 84143
[2] UNIV UTAH,COLL MED,DEPT BIOPHYS & BIOENGN,SALT LAKE CITY,UT 84112
[3] UNIV UTAH,COLL MED,DEPT ANESTHESIOL,SALT LAKE CITY,UT 84112
[4] UNIV UTAH,COLL MED,DEPT MED,DIV INFECT DIS,SALT LAKE CITY,UT 84112
关键词
D O I
10.1056/NEJM197405302902205
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
引用
收藏
页码:1227 / 1231
页数:5
相关论文
共 21 条
[2]   AN IMPROVED TECHNIC FOR PROLONGED ARTERIAL CANNULATION [J].
BARTLETT, RH ;
MUNSTER, AM .
NEW ENGLAND JOURNAL OF MEDICINE, 1968, 279 (02) :92-&
[3]   COMPLICATIONS OF PERCUTANEOUS RADIAL-ARTERY CANNULATION - OBJECTIVE PROSPECTIVE STUDY IN MAN [J].
BEDFORD, RF ;
WOLLMAN, H .
ANESTHESIOLOGY, 1973, 38 (03) :228-236
[4]   PERCUTANEOUS RADIAL ARTERY CANNULATION [J].
BROWN, AE ;
SWEENEY, DB ;
LUMLEY, J .
ANAESTHESIA, 1969, 24 (04) :532-&
[5]  
CAMPION BC, 1971, MAYO CLIN PROC, V46, P589
[6]   MAINTENANCE OF VENOUS POLYETHYLENE CATHETERS TO REDUCE RISK OF INFECTION [J].
CORSO, JA ;
AGOSTINELLI, R ;
BRANDRISS, MW .
JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1969, 210 (11) :2075-+
[7]   HAZARDS OF RADIAL-ARTERY CATHETERIZATION [J].
DOWNS, JB ;
RACKSTEIN, AD ;
KLEIN, EF ;
HAWKINS, IF .
ANESTHESIOLOGY, 1973, 38 (03) :283-286
[8]   INDWELLING INTRAVENOUS POLYETHYLENE CATHETERS - FACTORS INFLUENCING RISK OF MICROBIAL COLONIZATION AND SEPSIS [J].
FUCHS, PC .
JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1971, 216 (09) :1447-&
[9]   CATHETER-FLUSH SYSTEM FOR CONTINUOUS MONITORING OF CENTRAL ARTERIAL PULSE WAVEFORM [J].
GARDNER, RM ;
WARNER, HR ;
TORONTO, AF ;
GAISFORD, WD .
JOURNAL OF APPLIED PHYSIOLOGY, 1970, 29 (06) :911-&
[10]   AORTIC PULSE CONTOUR CALCULATION OF CARDIAC OUTPUT [J].
GRAVES, CL ;
STAUFFER, WM ;
KLEIN, RL ;
UNDERWOOD, PS .
ANESTHESIOLOGY, 1968, 29 (03) :580-+