FABRICATION AND EVALUATION OF POSTCAPILLARY JUNCTIONS VIA MICROSCALE MOLDING FOR USE AS REACTORS AND FLOW MULTIPLEXERS IN CAPILLARY ELECTROKINETIC SEPARATIONS

被引:6
作者
STALLER, TD
SEPANIAK, MJ
机构
[1] Department of Chemistry, University of Tennessee, Knoxville
基金
美国能源部;
关键词
D O I
10.1080/10739149508014119
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new method of micro-fabrication is developed and employed in the production of low dead volume junctions for two post capillary detection schemes. The application of the junction as a post capillary reactor for peroxyoxalate chemiluminescence detection is presented. Approximate detection limits of 2.5 x 10(-7) ($) under bar M and 9.1 x 10(-7) ($) under bar M are reported for perylene and anthracene (respectively) with a response linear over 3 orders of magnitude. A novel post capillary flow multiplexer is reported which utilizes electroosmotic flow switching to divert bands into secondary channels for off-line defection. The effect of solvent composition and reservoir geometry on electroosmotic flow switching times is described.
引用
收藏
页码:235 / 254
页数:20
相关论文
共 14 条
[1]  
Dadoo R., 1992, J HIGH RES CHROMATOG, V15, P133
[2]   STOPPED-FLOW DETERMINATION OF THE PARAMETERS AFFECTING THE APPLICATION OF PEROXYOXALATE CHEMI-LUMINESCENCE TO HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETECTION [J].
HANAOKA, N ;
GIVENS, RS ;
SCHOWEN, RL ;
KUWANA, T .
ANALYTICAL CHEMISTRY, 1988, 60 (20) :2193-2197
[3]   CAPILLARY ELECTROPHORESIS AND SAMPLE INJECTION SYSTEMS INTEGRATED ON A PLANAR GLASS CHIP [J].
HARRISON, DJ ;
MANZ, A ;
FAN, ZH ;
LUDI, H ;
WIDMER, HM .
ANALYTICAL CHEMISTRY, 1992, 64 (17) :1926-1932
[4]   EVALUATION OF ARYL OXALATES FOR CHEMILUMINESCENCE DETECTION IN HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
HONDA, K ;
MIYAGUCHI, K ;
IMAI, K .
ANALYTICA CHIMICA ACTA, 1985, 177 :103-110
[5]   USE OF AN ON-COLUMN FRIT IN CAPILLARY ZONE ELECTROPHORESIS - SAMPLE COLLECTION [J].
HUANG, XH ;
ZARE, RN .
ANALYTICAL CHEMISTRY, 1990, 62 (05) :443-446
[6]   MICROCHIP CAPILLARY ELECTROPHORESIS WITH AN INTEGRATED POSTCOLUMN REACTOR [J].
JACOBSON, SC ;
KOUTNY, LB ;
HERGENRODER, R ;
MOORE, AW ;
RAMSEY, JM .
ANALYTICAL CHEMISTRY, 1994, 66 (20) :3472-3476
[7]   USE OF AN ON-COLUMN FRACTURE IN CAPILLARY ZONE ELECTROPHORESIS FOR SAMPLE INTRODUCTION [J].
LINHARES, MC ;
KISSINGER, PT .
ANALYTICAL CHEMISTRY, 1991, 63 (18) :2076-2078
[8]  
ROSE DJ, 1988, J CHROMATOGR, V447, P117
[9]   ACRIDINIUM CHEMILUMINESCENCE DETECTION WITH CAPILLARY ELECTROPHORESIS [J].
RUBERTO, MA ;
GRAYESKI, ML .
ANALYTICAL CHEMISTRY, 1992, 64 (22) :2758-2762
[10]  
SEPANIAK MJ, 1992, HDB CAPILLARY ELECTR, pCH6