THERMOOPTIC ABSORPTION DETECTION IN 25-MU-M-ID CAPILLARIES - CAPILLARY ELECTROPHORESIS OF DANSYL-AMINO ACIDS MIXTURES

被引:40
作者
BRUNO, AE [1 ]
PAULUS, A [1 ]
BORNHOP, DJ [1 ]
机构
[1] LINEAR INSTRUMENTS,RENO,NV 89523
关键词
INSTRUMENTATION; DETECTION; LASERS; ANALYTICAL METHODS; SPECTROSCOPIC TECHNIQUES;
D O I
10.1366/0003702914337371
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
An intensity-modulated 257-nm pump laser beam is used to induce refractive index changes inside of a capillary tube employed as an on-line detection system for capillary electrophoresis. These refractive index changes inside the capillary are monitored by demodulating the periodic lateral shifts of the interference fringes, generated by a probe laser beam oscillating at 633 nm, with a phase-sensitive amplifier. The use of capillaries with an internal diameter of 25-mu-m results in a twofold benefit in electrophoretic separations in conjunction with thermo-optical detection. The pumped heat is efficiently quenched at the capillary wall, and high electrical fields can be applied along the separation tube. The combination of both effects leads to highly efficient separations and fast modulations of the pump source. This is demonstrated by the separation of a test mixture of three dansylated amino acids in less than two minutes. Only 350-pg amounts of total sample are injected onto the column, and the detection volume is less than 10 pL.
引用
收藏
页码:462 / 467
页数:6
相关论文
共 38 条
[1]   SIMULTANEOUS LASER-BASED REFRACTIVE-INDEX AND ABSORBENCY DETERMINATIONS WITHIN MICROMETER DIAMETER CAPILLARY TUBES [J].
BORNHOP, DJ ;
DOVICHI, NJ .
ANALYTICAL CHEMISTRY, 1987, 59 (13) :1632-1636
[2]   THEORETICAL CONSIDERATIONS ON THE DESIGN OF CYLINDRICAL FLOW CELLS UTILIZING OPTICAL FIBERS [J].
BRUNO, AE ;
KUHN, R ;
WIDMER, HM .
ANALYTICA CHIMICA ACTA, 1990, 234 (01) :259-262
[3]   ON-COLUMN CAPILLARY-FLOW CELL UTILIZING OPTICAL WAVE-GUIDES FOR CHROMATOGRAPHIC APPLICATIONS [J].
BRUNO, AE ;
GASSMANN, E ;
PERICLES, N ;
ANTON, K .
ANALYTICAL CHEMISTRY, 1989, 61 (08) :876-883
[4]   THERMAL LENS ABSORPTION-MEASUREMENTS ON SMALL VOLUME SAMPLES [J].
CARTER, CA ;
HARRIS, JM .
ANALYTICAL CHEMISTRY, 1984, 56 (06) :922-925
[5]   SUBATTOMOLE AMINO-ACID ANALYSIS BY CAPILLARY ZONE ELECTROPHORESIS AND LASER-INDUCED FLUORESCENCE [J].
CHENG, YF ;
DOVICHI, NJ .
SCIENCE, 1988, 242 (4878) :562-564
[6]   HIGH-PERFORMANCE CAPILLARY ELECTROPHORETIC SEPARATION OF BASES, NUCLEOSIDES, AND OLIGONUCLEOTIDES - RETENTION MANIPULATION VIA MICELLAR SOLUTIONS AND METAL ADDITIVES [J].
COHEN, AS ;
TERABE, S ;
SMITH, JA ;
KARGER, BL .
ANALYTICAL CHEMISTRY, 1987, 59 (07) :1021-1027
[7]   HIGH-PERFORMANCE CAPILLARY ELECTROPHORESIS USING OPEN TUBES AND GELS [J].
COHEN, AS ;
PAULUS, A ;
KARGER, BL .
CHROMATOGRAPHIA, 1987, 24 :15-24
[8]   THERMOOPTIC SPECTROPHOTOMETRIES IN ANALYTICAL-CHEMISTRY [J].
DOVICHI, NJ .
CRC CRITICAL REVIEWS IN ANALYTICAL CHEMISTRY, 1987, 17 (04) :357-423
[9]   CAPILLARY ELECTROPHORESIS [J].
EWING, AG ;
WALLINGFORD, RA ;
OLEFIROWICZ, TM .
ANALYTICAL CHEMISTRY, 1989, 61 (04) :A292-+