EXPERIMENTAL-ANALYSIS OF THE MULTI-BYPASS PRINCIPLE IN PULSE TUBE REFRIGERATORS

被引:19
作者
CAI, JH
WANG, JJ
ZHU, WX
ZHOU, Y
机构
[1] Cryogenic Laboratory, Academia Sinica, 2711 Beijing, PO Box
关键词
REFRIGERATION; MULTI-BYPASS METHOD; COAXIAL PULSE TUBE REFRIGERATOR;
D O I
10.1016/0011-2275(94)90155-4
中图分类号
O414.1 [热力学];
学科分类号
摘要
This paper describes the structural characteristics and the mechanical performance of a co-axial pulse tube refrigerator with a multi-bypass. Some experimental results and an experimental analysis of the multi-bypass method are also given. The minimum attainable temperature at the cold end of a co-axial pulse tube refrigerator with multi-bypass is 33 K at a vacuum of 1 x 10(-4) torr. This shows that the performance of a pulse lube refrigerator is comparable to that of a Stirling refrigerator. Moreover, pulse tube systems would probably be more extensively used than Stirling refrigerators because of their advantages in terms of structural simplicity and mechanical reliability.
引用
收藏
页码:713 / 715
页数:3
相关论文
共 3 条
[1]   EXPERIMENTAL-ANALYSIS OF DOUBLE-INLET PRINCIPLE IN PULSE TUBE REFRIGERATORS [J].
CAI, JH ;
ZHOU, Y ;
WANG, JJ ;
ZHU, WX .
CRYOGENICS, 1993, 33 (05) :522-525
[2]   DEVELOPMENT OF A SINGLE-STAGE PULSE TUBE REFRIGERATOR CAPABLE OF REACHING 49-K [J].
LIANG, J ;
ZHOU, Y ;
ZHU, W .
CRYOGENICS, 1990, 30 (01) :49-51
[3]  
ZHOU Y, 1992, 7TH INT CRYOC C SANT