摘要
Although air showers are a common feature in industrial cleanroom facilities, their contribution to a successful particle control program has been questioned. In the study reported here, tests were carried out to determine the effectiveness of an air shower within a cleanroom suite. The particle dispersal rates from volunteers who had passed through or walked around outside of an air shower were measured in a test chamber, and it was found that the use of the air shower had no significant effect. Further tests showed that airborne particle counts in the cleanroom were not significantly affected by employees' use of the air shower. Thus it was concluded that air showers have little value in reducing particle dispersion from cleanroom personnel.
引用
收藏
页码:39 / &
相关论文
共 50 条
  • [21] The implication of charged particle lateral distribution function for extensive air shower studies
    Fomin, Yu. A.
    Kalmykov, N. N.
    Kempa, J.
    Kulikov, G. V.
    Sulakov, V. P.
    NUCLEAR PHYSICS B-PROCEEDINGS SUPPLEMENTS, 2008, 175 : 334 - 337
  • [22] Air Shower Simulations
    Alania, Marco
    Araya, Ignacio J.
    Chamorro Gomez, Adolfo V.
    Martinez Huerta, Humberto
    Parra Flores, Alejandra
    Knapp, Johannes
    COSMIC RAYS AND ASTROPHYSICS, 2009, 1123 : 150 - +
  • [23] ON THE AIR SHOWER CORE
    HASEGAWA, S
    PROGRESS OF THEORETICAL PHYSICS, 1957, 17 (04): : 603 - 605
  • [24] CHARACTERIZATION OF CLEANROOM WIPERS - PARTICLE GENERATION
    KWOK, WK
    SUMMERS, JT
    JOURNAL OF THE IES, 1990, 33 (06): : 33 - 39
  • [25] Effects of supply air temperature and inlet locations on particle dispersion in a displacement ventilated room
    Kang, Yanming
    Wang, Youjun
    Zhong, Ke
    FIRST INTERNATIONAL CONFERENCE ON BUILDING ENERGY AND ENVIRONMENT, PROCEEDINGS VOLS 1-3, 2008, : 991 - 998
  • [26] How dean is your cleanroom air?
    Camenzind, MJ
    Liang, HJ
    Fucsko, J
    Balazs, MK
    MICRO, 1995, 13 (09): : 49 - &
  • [27] Extensive air shower characteristics as functions of shower age
    Giller, M
    Stojek, H
    Wieczorek, G
    INTERNATIONAL JOURNAL OF MODERN PHYSICS A, 2005, 20 (29): : 6821 - 6824
  • [28] AIR SHOWER GROUP .3. MEASUREMENTS AT VARIOUS COMPONENTS OF AIR SHOWER
    BOHM, E
    ATOMKERNENERGIE, 1972, 20 (03): : 187 - 188
  • [29] The Effect of Air Change Rate and Cleanroom Garment on Cleanliness in Grade B Cleanroom
    Li Hao
    Zou Zhijun
    Wang Fei
    MACHINERY ELECTRONICS AND CONTROL ENGINEERING III, 2014, 441 : 514 - 517
  • [30] INDOOR AIR IS NEARLY CLEANROOM QUALITY
    TRISSEL, LA
    CHANDLER, SW
    ANDERSON, RW
    AMERICAN JOURNAL OF HOSPITAL PHARMACY, 1993, 50 (09): : 1858 - &