Nondestructive Evaluation of Microstructure of SiCf/SiC Composites by X-Ray Computed Microtomography

被引:6
作者
Kim, Weon-Ju [1 ]
Kim, Daejong [1 ]
Jung, Choong Hwan [1 ]
Park, Ji Yeon [1 ]
Snead, Lance L. [2 ]
机构
[1] Korea Atom Energy Res Inst, Nucl Mat Div, Daejeon 305353, South Korea
[2] Oak Ridge Natl Lab, Mat Sci & Technol Div, Oak Ridge, TN 37831 USA
基金
新加坡国家研究基金会;
关键词
X-ray computed microtomography; SiCf/SiC composite; Microstructure; Nondestructive evaluation;
D O I
10.4191/kcers.2013.50.6.378
中图分类号
TQ174 [陶瓷工业]; TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Continuous fiber-reinforced ceramic matrix composites (CFCCs) have a complex distribution of porosity, consisting of interfiber micro pores and interbundle/interply macro pores. Owing to the complex geometry of the pores and fiber architecture, it is difficult to obtain representative microstructural features throughout the specimen volume with conventional, destructive ceramographic approaches. In this study, we introduce X-ray computed microtomography (X-ray mu ACT) to nondestructively analyze the microstructures of disk shaped and tubular SiCf/SiC composites fabricated by the chemical vapor infiltration (CVI) method. The disk specimen made by stacking plain-woven SiC fabrics exhibited periodic, large fluctuation of porosity in the stacking direction but much less variation of porosity perpendicular to the fabric planes. The X-ray mu ACT evaluation of the microstructure was also effectively utilized to improve the fabrication process of the triple-layered tubular SiC composite.
引用
收藏
页码:378 / 383
页数:6
相关论文
共 29 条
  • [1] Microscopy - Nanotomography comes of age
    Attwood, David
    [J]. NATURE, 2006, 442 (7103) : 642 - 643
  • [2] Analysis of pore interconnectivity in bioactive glass foams using X-ray microtomography
    Atwood, RC
    Jones, JR
    Lee, PD
    Hench, LL
    [J]. SCRIPTA MATERIALIA, 2004, 51 (11) : 1029 - 1033
  • [3] Bale HA, 2013, NAT MATER, V12, P40, DOI [10.1038/NMAT3497, 10.1038/nmat3497]
  • [4] Advances in synchrotron radiation microtomography
    Baruchel, Jos
    Buffiere, Jean-Yves
    Cloetens, Peter
    Di Michiel, Marco
    Ferrie, Emilie
    Ludwig, Wolfgang
    Maire, Eric
    Salvo, Luc
    [J]. SCRIPTA MATERIALIA, 2006, 55 (01) : 41 - 46
  • [5] In-situ synchrotron X-ray microtomography studies of microstructure and damage evolution in engineering materials
    Beckmann, Felix
    Grupp, Rainer
    Haibel, Astrid
    Huppmann, Michael
    Noethe, Michael
    Pyzalla, Anke
    Reimers, Walter
    Schreyer, Andreas
    Zettler, Rudolf
    [J]. ADVANCED ENGINEERING MATERIALS, 2007, 9 (11) : 939 - 950
  • [6] Bray DE., 1992, NONDESTRUCTIVE TESTI
  • [7] Chaffron L., 2010, NUCL FUELS STRUCTURA
  • [8] In situ X-ray microtomography characterization of damage in SiCf/SiC minicomposites
    Chateau, C.
    Gelebart, L.
    Bornert, M.
    Crepin, J.
    Boller, E.
    Sauder, C.
    Ludwig, W.
    [J]. COMPOSITES SCIENCE AND TECHNOLOGY, 2011, 71 (06) : 916 - 924
  • [9] Nondestructive Characterization of High-Performance C/SiC-Ceramics Using X-Ray-Computed Tomography
    Hausherr, Jan Marcel
    Krenkel, Walter
    Fischer, Frank
    Altstadt, Volker
    [J]. INTERNATIONAL JOURNAL OF APPLIED CERAMIC TECHNOLOGY, 2010, 7 (03) : 361 - 368
  • [10] X-ray tomography observation of crack propagation in nuclear graphite
    Hodgkins, A.
    Marrow, T. J.
    Mummery, P.
    Marsden, B.
    Fok, A.
    [J]. MATERIALS SCIENCE AND TECHNOLOGY, 2006, 22 (09) : 1045 - 1051