CORNEAL ENDOTHELIAL-CELL LOSS AFTER PHACOEMULSIFICATION USING NUCLEAR CRACKING PROCEDURES

被引:47
|
作者
HAYASHI, K
NAKAO, F
HAYASHI, F
机构
[1] Hayashi Eye Hospital, Fukuoka
关键词
ENDOTHELIAL CELL LOSS; NUCLEAR CRACKING; PHACOEMULSIFICATION;
D O I
10.1016/S0886-3350(13)80042-9
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
This study assessed corneal endothelial damage in endocapsular phacoemulsification surgery using a nuclear cracking procedure in which the nucleus was divided into four quadrants and emulsified. Forty-five eyes had phacoemulsification using this technique, and 33 eyes had phacoemulsification using undivided sculpting techniques (without cracking). We examined the extent of endothelial cell loss at one and three months after surgery using specular microscopy. We also measured ultrasound time, time spent for phacoemulsification, and infusion volume during surgery. Endothelial cell loss was significantly less in the nuclear cracking group than in the undivided sculpting group. Ultrasound time in surgery with cracking was significantly shorter than that in surgery without cracking. The time for the phacoemulsification maneuvers and the infusion volume were the same for both procedures. These findings indicate that the ultrasound time was shortened using the nuclear cracking technique and resulted in less corneal injury.
引用
收藏
页码:44 / 47
页数:4
相关论文
共 50 条
  • [11] Accelerated corneal endothelial cell loss in two patients with granulomatosis with polyangiitis following phacoemulsification
    Fang-Chi Hsiao
    Hung-Ta Chen
    Kuan-Jen Chen
    Yi-Jen Hsueh
    Yaa-Jyuhn James Meir
    Tsai-Te Lu
    Chao-Min Cheng
    Wei-Chi Wu
    Hung-Chi Chen
    BMC Ophthalmology, 20
  • [12] Accelerated corneal endothelial cell loss in two patients with granulomatosis with polyangiitis following phacoemulsification
    Hsiao, Fang-Chi
    Chen, Hung-Ta
    Chen, Kuan-Jen
    Hsueh, Yi-Jen
    Meir, Yaa-Jyuhn James
    Lu, Tsai-Te
    Cheng, Chao-Min
    Wu, Wei-Chi
    Chen, Hung-Chi
    BMC OPHTHALMOLOGY, 2020, 20 (01)
  • [13] A Comparison of Endothelial Cell Loss After Phacoemulsification in Penetrating Keratoplasty Patients and Normal Patients
    Kim, Eun Chul
    Kim, Man Soo
    CORNEA, 2010, 29 (05) : 510 - 515
  • [14] EFFECTS OF HEALON VS VISCOAT ON ENDOTHELIAL-CELL COUNT AND MORPHOLOGY AFTER PHACOEMULSIFICATION AND POSTERIOR CHAMBER LENS IMPLANTATION
    RAFUSE, PE
    NICHOLS, BD
    CANADIAN JOURNAL OF OPHTHALMOLOGY-JOURNAL CANADIEN D OPHTALMOLOGIE, 1992, 27 (03): : 125 - 129
  • [15] Relationship Between Postoperative Oxidative Stress Levels and Corneal Endothelial Cell Loss After Phacoemulsification in Diabetic Patients with Cataract
    Gao, Yuan
    Yang, Ning
    Wei, Lijuan
    Yan, Yijie
    Li, Lei
    CLINICAL OPHTHALMOLOGY, 2024, 18 : 3957 - 3965
  • [16] CORNEAL ENDOTHELIAL RESPONSE TO POLYMETHYLMETHACRYLATE VERSUS HYDROGEL LENSES AFTER PHACOEMULSIFICATION
    TINGEY, DP
    NICHOLS, BD
    JUNG, SEL
    RANDALL, PE
    CANADIAN JOURNAL OF OPHTHALMOLOGY-JOURNAL CANADIEN D OPHTALMOLOGIE, 1991, 26 (01): : 3 - 6
  • [17] ENDOTHELIAL-CELL LOSS AFTER 4 MM CATARACT-SURGERY
    LAVERY, KT
    MCDERMOTT, ML
    ERNEST, PH
    EDELHAUSER, HF
    KIESSLING, LA
    HOLLEY, G
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1995, 21 (03) : 305 - 308
  • [18] Comparison of effective phacoemulsification time and corneal endothelial cell loss using three different ultrasound frequencies: A randomized controlled trial
    Dewan, Taru
    Malik, Praveen K.
    Tomar, Preeti
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2022, 70 (04) : 1180 - 1185
  • [19] Corneal endothelial function after phacoemulsification using the fluid-based system compared to conventional ultrasound technique
    A Tsorbatzoglou
    K Kertész
    L Módis
    G Németh
    J Máth
    A Berta
    Eye, 2007, 21 : 727 - 732
  • [20] Corneal endothelial function after phacoemulsification using the fluid-based system compared to conventional ultrasound technique
    Tsorbatzoglou, A.
    Kertesz, K.
    Modis, L.
    Nemeth, G.
    Math, J.
    Berta, A.
    EYE, 2007, 21 (06) : 727 - 732