ALTERNATIVE APPROACHES TO RIGHT-VENTRICULAR ENDOMYOCARDIAL BIOPSY

被引:5
作者
CORLEY, DD
STRICKMAN, N
机构
[1] ST LUKES EPISCOPAL HOSP,TEXAS HEART INST,HOUSTON,TX 77030
[2] BAYLOR COLL MED,HOUSTON,TX 77030
来源
CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS | 1994年 / 31卷 / 03期
关键词
ENDOMYOCARDIAL BIOPSY; BIOPSY-METHODS; CARDIOMYOPATHY; TRANSPLANTATION-HEART;
D O I
10.1002/ccd.1810310316
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Cardiologists are performing endomyocardial biopsy procedures with increasing frequency, particularly in patients who have undergone cardiac transplantation. Because of the necessity for performing multiple biopsies in many of these patients and the subsequent complications that may arise, we have developed a simple and efficient technique for obtaining endomyocardial biopsy samples. As an alternative to retrieving biopsy samples by the conventional right internal jugular or femoral venous approach, we use the right or left internal jugular or subclavian approach. The procedure utilizes a 7 Fr 35 cm sheath and dilator system placed into the right ventricle over a balloon-tipped catheter. After the sheath is positioned via either the internal jugular or subclavian vein, multiple samples can be obtained with standard available bioptomes. The sheath may then be exchanged for a triple-lumen catheter if desired. This approach permits routine changing of the central venous access lines within the sterile confines of the catheterization laboratory, with minimal discomfort to patients. We believe that this method represents an important alternative to conventional biopsy techniques. (C) 1994 Wiley-Liss, Inc.
引用
收藏
页码:236 / 239
页数:4
相关论文
共 12 条
[1]   THE FEMORAL VENOUS APPROACH TO ENDOMYOCARDIAL BIOPSY - COMPARISON WITH INTERNAL JUGULAR AND TRANSARTERIAL APPROACHES [J].
ANDERSON, JL ;
MARSHALL, HW .
AMERICAN JOURNAL OF CARDIOLOGY, 1984, 53 (06) :833-837
[2]   MORBIDITY OF ENDOMYOCARDIAL BIOPSY IN CARDIAC TRANSPLANT RECIPIENTS [J].
BHAT, G ;
BURWIG, S ;
WALSH, R .
AMERICAN HEART JOURNAL, 1993, 125 (04) :1180-1181
[3]   RUPTURED CHORDAE TENDINEAE OF THE TRICUSPID-VALVE AS A COMPLICATION OF ENDOMYOCARDIAL BIOPSY IN HEART-TRANSPLANT PATIENTS [J].
BRAVERMAN, AC ;
COPLEN, SE ;
MUDGE, GH ;
LEE, RT .
AMERICAN JOURNAL OF CARDIOLOGY, 1990, 66 (01) :111-113
[4]   PERCUTANEOUS TRANSVENOUS ENDOMYOCARDIAL BIOPSY [J].
CAVES, PK ;
STINSON, EB ;
GRAHAM, AF ;
BILLINGHAM, ME ;
GREHL, TM ;
SHUMWAY, NE .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1973, 225 (03) :288-291
[5]   USE OF A BALLOON-TIPPED CATHETER TO GUIDE PLACEMENT OF THE BIOPTOME SHEATH IN RIGHT VENTRICULAR PERCUTANEOUS ENDOMYOCARDIAL BIOPSY [J].
JOHNSON, DE ;
VACEK, JL ;
DUNN, M .
CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1988, 14 (03) :214-217
[6]  
LEW BT, 1987, CATHET CARDIOVASC DI, V13, P311
[7]   CLINICAL MERIT OF ENDOMYOCARDIAL BIOPSY [J].
MASON, JW ;
OCONNELL, JB .
CIRCULATION, 1989, 79 (05) :971-979
[8]   TECHNIQUES FOR RIGHT AND LEFT-VENTRICULAR ENDOMYOCARDIAL BIOPSY [J].
MASON, JW .
AMERICAN JOURNAL OF CARDIOLOGY, 1978, 41 (05) :887-892
[9]   ENDOMYOCARDIAL BIOPSY - A REVIEW OF THE LITERATURE [J].
PRZYBOJEWSKI, JZ .
CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1985, 11 (03) :287-330
[10]  
RICHARDSON PJ, 1985, HEART VESSELS S, V1, P83