MEASURING THE ABSOLUTE SENSITIVITY OF AN X-RAY ELECTRON-OPTICAL IMAGE CONVERTER IN THE RANGE 7-20 KEV

被引:1
|
作者
DOLBNYA, IP
KNYAZEV, BA
SIMONOV, VP
FELDMAN, GG
机构
[1] Institute of Nuclear Physics
关键词
D O I
10.1016/0168-9002(91)90688-M
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The absolute sensitivity of an X-ray electron-optical image converter with a MCP used as both photocathode and amplifier has been investigated using synchrotron radiation from the VEPP-3 storage ring (INP, Novosibirsk) in the energy range of 7 to 20 keV. In this spectral range the response of the converter increases from 1200 to 2200 blue photons at the output per one incident X-ray quantum. The distribution of the sensitivity along the image field has been also studied.
引用
收藏
页码:435 / 437
页数:3
相关论文
共 50 条
  • [1] ABSOLUTE SENSITIVITY OF X-RAY IMAGE CONVERTER IN THE RANGE OF 7-20 KEV
    DOLBNYA, IP
    KNYAZEV, BA
    SIMONOV, VP
    FELDMAN, GG
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1990, 33 (04) : 950 - 952
  • [2] ABSOLUTE SPECTRAL SENSITIVITY OF LINEAR-PHOTODIODE ARRAYS IN 7-20 KEV ENERGY X-RAY RANGE
    DOLBNYA, IP
    KURYLO, SG
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1992, 63 (01): : 677 - 679
  • [3] CHARACTERISTICS OF ELECTRON-OPTICAL AND X-RAY IMAGE INTENSIFIERS
    GURVICH, AM
    SHAMANOV, AA
    ROZENBERG, AM
    FAINBERG, VS
    KAVTOROVA, VP
    SALYUK, LV
    YAKOVLEVA, FB
    SOVIET JOURNAL OF NONDESTRUCTIVE TESTING-USSR, 1978, 14 (02): : 126 - 131
  • [4] Generation of powerful X-rays in the range 7-20 keV
    Ratakhin N.A.
    Russian Physics Journal, 1997, 40 (12) : 1198 - 1203
  • [5] ELECTRON-OPTICAL RECORD OF X-RAY DIFFRACTION
    MOKULSKA.TD
    MOKULSKI.MA
    DOKLADY AKADEMII NAUK SSSR, 1966, 166 (04): : 836 - &
  • [6] ELECTRON-OPTICAL METHODS FOR STUDY IN X-RAY RANGE ON BASIS OF PLASTIC SCINTILLATORS
    BRYUKHNEVICH, GI
    KASYANOV, YS
    STEPANOV, BM
    CHEVOKIN, VK
    SHCHELEV, MY
    PRIBORY I TEKHNIKA EKSPERIMENTA, 1975, (06): : 228 - 231
  • [7] DETERMINATION OF DYNAMIC-RANGE OF X-RAY EOT (ELECTRON-OPTICAL TRANSDUCERS)
    DASHEVSKII, BE
    MALYUTIN, AA
    MAKHMUTOV, RK
    PODVYAZNIKOV, VA
    CHEVOKIN, VK
    YAKUNIN, VS
    PISMA V ZHURNAL TEKHNICHESKOI FIZIKI, 1989, 15 (08): : 44 - 47
  • [8] SENSITIVITY OF RI-10E ELECTRON-OPTICAL X-RAY INTROSCOPE
    KANTER, BM
    LEONOV, BI
    KHIMOVICH, YR
    ZAVODSKAYA LABORATORIYA, 1975, 41 (03): : 323 - 325
  • [9] PHOTORECORDING OF X-RAY PICTURES BY ELECTRON-OPTICAL TRANSFORMERS
    BRYZGUNOV, VA
    ZHURNAL NAUCHNOI I PRIKLADNOI FOTOGRAFII, 1971, 16 (03): : 209 - +
  • [10] PHOTOCATHODES FOR X-RAY ELECTRON-OPTICAL CONVERTERS.
    Baeva, E.D.
    Zak, E.I.
    Kondrashova, L.I.
    Stepanov, B.M.
    Tverdokhleb, I.G.
    Instruments and experimental techniques New York, 1982, 25 (4 pt 2): : 988 - 990