A computer model of broad beam transmission through lead material for gamma rays and X-rays of different energies

被引:0
作者
Al-Lehyani, Saud H. [1 ]
机构
[1] Umm Al Qura Univ, Fac Sci Appl, Dept Phys, POB 10130, Mecca, Saudi Arabia
关键词
Monte Carlo; Simulation; gamma Rays; High-energy X-rays; Radiotherapy;
D O I
10.1017/S146039690999032X
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In radiotherapy, the radiation beam is sometimes shaped so as to deliver different doses to different organs or give a homogeneous dose to structures of different densities. This objective is achieved by the use of attenuating materials introduced into the radiation beam. These attenuators alter the primary as well as the scattered radiation components of the beam and there is at present no accurate method of dose calculation for these situations. Most calculations are performed considering only the effect of the attenuators on the primary radiation beam and can produce large errors in dosimetry. In this study, the broad-beam attenuation is investigated in homogeneous phantoms for various radiation field sizes, photon beam energies and depths in phantom. A mathematical method taking account of primary as well as first scattered radiation is developed. This method predicts reasonably well the transmission through lead attenuators for various experimental conditions.
引用
收藏
页码:149 / 163
页数:15
相关论文
共 21 条
[1]  
Al-Ghorabie FH, APPL RAD ISOT UNPUB
[2]   MONTE-CARLO TECHNIQUES IN MEDICAL RADIATION PHYSICS [J].
ANDREO, P .
PHYSICS IN MEDICINE AND BIOLOGY, 1991, 36 (07) :861-920
[3]  
Attix F. H., 1986, INTRO RADIOLOGICAL P
[4]   REFLECTION AND TRANSMISSION OF GAMMA RADIATION BY BARRIERS - SEMIANALYTIC MONTE-CARLO CALCULATION [J].
BERGER, MJ ;
DOGGETT, J .
JOURNAL OF RESEARCH OF THE NATIONAL BUREAU OF STANDARDS, 1956, 56 (02) :89-98
[5]  
Briesmeister JF, 1998, LA12625 LOS AL NAT L
[6]  
FANO U, 1953, NUCLEONICS, V11, P55
[7]   SCATTERED PHOTONS PRODUCED BY BEAM-MODIFYING FILTERS [J].
HUANG, PH ;
CHIN, LM ;
BJARNGARD, BE .
MEDICAL PHYSICS, 1986, 13 (01) :57-63
[8]  
ICRU, 1976, 24 ICRU
[9]   Tenth value layers for 60Co gamma rays and for 4, 6, 10, 15, and 18 MV X rays in concrete for beams of cone angles between 0° and 14° calculated by Monte Carlo simulation [J].
Jaradat, Adnan K. ;
Biggs, Peter J. .
HEALTH PHYSICS, 2007, 92 (05) :456-463
[10]  
Johns H. E., 1983, PHYS RADIOLOGY