Biomechanical measures of knee joint mobilization

被引:15
|
作者
Silvernail, Jason [1 ]
Gill, Norman [1 ]
Teyhen, Deydre [1 ,2 ]
Allison, Stephen [1 ]
机构
[1] Brooke Army Med Ctr, Orthopaed Manual Phys Therapy, San Antonio, TX USA
[2] Baylor Univ, US Army, Doctoral Program Phys Therapy, Ft Sam Houston, TX USA
关键词
Knee Joint; Mobilization; Manual therapy; Biomechanics; Joint; Orthopedic; Force; Reliability;
D O I
10.1179/2042618611Y.0000000012
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Background and purpose: The purpose of this study was to quantify the biomechanical properties of specific manual therapy techniques in patients with symptomatic knee osteoarthritis. Methods: Twenty subjects (7 female/13 male, age 54 +/- 8 years, ht 1.7 +/- 0.1 m, wt 94.2 +/- 21.8 kg) participated in this study. One physical therapist delivered joint mobilizations (tibiofemoral extension and flexion; patellofemoral medial- lateral and inferior glide) at two grades (Maitland's grade III and grade IV). A capacitance-based pressure mat was used to capture biomechanical characteristics of force and frequency during 2 trials of 15 second mobilizations. Statistical analysis included intraclass correlation coefficient (ICC3,1) for intrarater reliability and 264 repeated measures analyses of variance and post- hoc comparison tests. Results: Force (Newtons) measurements (mean, max.) for grade III were: extension 45, 74; flexion 39, 61; medial-lateral glide 20, 34; inferior glide 16, 27. Force (Newtons) measurements (mean, max.) for grade IV were: extension 57, 76; flexion 47, 68; medial-lateral glide 23, 36; inferior glide 18, 35. Frequency (Hz) measurements were between 0.9 and 1.2 for grade III, and between 2.1 and 2.4 for grade IV. ICCs were above 0.90 for almost all measures. Discussion and conclusion: Maximum force measures were between the ranges reported for cervical and lumbar mobilization at similar grades. Mean force measures were greater at grade IV than III. Oscillation frequency and peak-to- peak amplitude measures were consistent with the grade performed (i.e. greater frequency at grade IV, greater peak-to-peak amplitude at grade III). Intrarater reliability for force, peak-topeak amplitude and oscillation frequency for knee joint mobilizations was excellent.
引用
收藏
页码:162 / 171
页数:10
相关论文
共 50 条
  • [41] Effect of joint mobilization techniques for primary total knee arthroplasty Study protocol for a randomized controlled trial
    Xu, Jiao
    Zhang, Juan
    Wang, Xue-Qiang
    Wang, Xuan-Lin
    Wu, Ya
    Chen, Chan-Cheng
    Zhang, Han-Yu
    Zhang, Zhi-Wan
    Fan, Kai-Yi
    Zhu, Qiang
    Deng, Zhi-Wei
    MEDICINE, 2017, 96 (49)
  • [42] Tension changes in the collateral ligaments of a cruciate ligament-deficient knee joint: an experimental biomechanical study
    Hinterwimmer, S
    Baumgart, R
    Plitz, W
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2002, 122 (08) : 454 - 458
  • [43] Full biomechanical mapping of the ovine knee joint to determine creep-recovery, stiffness and thickness variation
    Pflieger, Iris
    Stolberg-Stolberg, Josef
    Foehr, Peter
    Kuntz, Lara
    Tuebel, Jutta
    Grosse, Christian U.
    Burgkart, Rainer
    CLINICAL BIOMECHANICS, 2019, 67 (1-7) : 1 - 7
  • [44] Effects of joint contracture on the contralateral unoperated limb in a rabbit knee contracture model: A biomechanical and genetic study
    Abdel, Matthew P.
    Morrey, Mark E.
    Grill, Diane E.
    Kolbert, Christopher P.
    An, Kai-Nan
    Steinmann, Scott P.
    Sanchez-Sotelo, Joaquin
    Morrey, Bernard F.
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2012, 30 (10) : 1581 - 1585
  • [45] BIOMECHANICAL ANALYSIS OF KNEE JOINT INJURIES CAUSED BY TORNADO KICK TURN 720° TO HORSE STEP LANDING
    Wang, Hui
    Ge, Zhiqiang
    Wu, Jiwei
    Yang, Jie
    ACTA MEDICA MEDITERRANEA, 2017, 33 : 1297 - 1300
  • [46] Design and biomechanical analysis of patient- specific porous tantalum prostheses for knee joint revision surgery
    Mao, Shilong
    Liu, Yang
    Wang, Fuyou
    He, Peng
    Wu, Xianzhe
    Ma, Xingshuang
    Luo, Yanfeng
    INTERNATIONAL JOURNAL OF BIOPRINTING, 2023, 9 (04)
  • [47] Posterolateral aspect and stability of the knee joint. I. Anatomy and function of the popliteus muscle-tendon unit: an anatomical and biomechanical study
    Ullrich, K
    Krudwig, WK
    Witzel, U
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2002, 10 (02) : 86 - 90
  • [48] Biomechanical Modelling of the Wrist Joint
    Eschweiler, J.
    Allmendinger, F.
    Stromps, J. P.
    Nick, H. E.
    Pallua, N.
    Radermacher, K.
    ZEITSCHRIFT FUR ORTHOPADIE UND UNFALLCHIRURGIE, 2014, 152 (02): : 161 - 169
  • [49] Biomechanical Particularities in the Therapy of the Rheumatic Knee
    Biehl, Christoph
    Heinrich, Martin
    Biehl, Lotta
    Knapp, Gero
    Heiss, Christian
    Thormann, Ulrich
    APPLIED SCIENCES-BASEL, 2020, 10 (23): : 1 - 12
  • [50] Biomechanical aspects of knee implant design