FULLY AUTOMATED METHODS FOR THE DETERMINATION OF HYDROCHLOROTHIAZIDE IN HUMAN PLASMA AND URINE

被引:29
作者
HSIEH, JYK [1 ]
LIN, C [1 ]
MATUSZEWSKI, BK [1 ]
DOBRINSKA, MR [1 ]
机构
[1] MERCK SHARP & DOHME LTD,DEPT DRUG METAB,RES LABS,W POINT,PA 19486
关键词
DIURETIC AND ANTIHYPERTENSIVE AGENT; HYDROCHLOROTHIAZIDE; LIQUID CHROMATOGRAPHY; LABORATORY ROBOTICS; PYTECHNOLOGY(TM) ROBOTIC SYSTEM; BENCHMATE(TM) WORKSTATION; AUTOMATED SAMPLE PREPARATION METHODS;
D O I
10.1016/0731-7085(94)00096-4
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
LC assays utilizing fully automated sample preparation procedures on Zymark PyTechnology(TM) Robot and BenchMate(TM) Workstation for the quantification of hydrochlorothiazide (HCTZ) in human plasma and urine have been developed. After aliquoting plasma and urine samples, and adding internal standard (IS) manually, the robot executed buffer and organic solvent addition, liquid-liquid extraction, solvent evaporation and on-line LC injection steps for plasma samples, whereas, BenchMate(TM) performed buffer and organic solvent addition, liquid-liquid and solid-phase extractions, and an-line LC injection steps for urine samples. Chromatographic separations were carried out on Beckman Octyl Ultrasphere column using the mobile phase composed of 12% (v/v) acetonitrile and 88% of either an ion-pairing reagent (plasma) or 0.1% trifluoroacetic acid (urine). The eluent from the column was monitored with UV detector (271 nm). Peak heights for HCTZ and IS were automatically processed using a PE-Nelson ACCESS*CHROM laboratory automation system. The assays have been validated in the concentration range of 2-100 ng ml(-1) in plasma and 0.1-20 mu g ml(-1) in urine. Both plasma and urine assays have the sensitivity and specificity necessary to determine plasma and urine concentrations of HCTZ from low dose (6.25/12.5 mg) administration of HCTZ to human subjects in the presence or absence of losartan.
引用
收藏
页码:1555 / 1562
页数:8
相关论文
共 16 条
[1]   SENSITIVE LIQUID-CHROMATOGRAPHIC METHOD FOR THE DETERMINATION OF HYDROCHLOROTHIAZIDE IN HUMAN PLASMA [J].
AZUMAYA, CT .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1990, 532 (01) :168-174
[2]   PHARMACOKINETICS OF HYDROCHLOROTHIAZIDE IN MAN [J].
BEERMANN, B ;
GROSCHINSKYGRIND, M .
EUROPEAN JOURNAL OF CLINICAL PHARMACOLOGY, 1977, 12 (04) :297-303
[3]   PHARMACOKINETICS OF HYDROCHLOROTHIAZIDE IN PATIENTS WITH CONGESTIVE HEART-FAILURE [J].
BEERMANN, B ;
GROSCHINSKYGRIND, M .
BRITISH JOURNAL OF CLINICAL PHARMACOLOGY, 1979, 7 (06) :579-583
[4]  
BEERMANN B, 1976, CLIN PHARMACOL THER, V19, P531
[5]  
DEPPLER P, 1981, ANAL PROFILES DRUG S, P405
[6]   SIMPLE DETERMINATION OF HYDROCHLOROTHIAZIDE IN HUMAN PLASMA AND URINE BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
DEVRIES, JX ;
VOSS, A .
BIOMEDICAL CHROMATOGRAPHY, 1993, 7 (01) :12-14
[7]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETERMINATION OF HYDROCHLOROTHIAZIDE IN PLASMA AND URINE [J].
KOOPMANS, PP ;
TAN, Y ;
VANGINNEKEN, CAM ;
GRIBNAU, FWJ .
JOURNAL OF CHROMATOGRAPHY, 1984, 307 (02) :445-450
[8]   A LIQUID-CHROMATOGRAPHIC METHOD FOR THE DETERMINATION OF HYDROCHLOROTHIAZIDE IN HUMAN PLASMA [J].
MILLER, RB ;
AMESTOY, C .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1992, 10 (07) :541-545
[9]   BIOAVAILABILITY OF HYDROCHLOROTHIAZIDE FROM TABLETS AND SUSPENSIONS [J].
PATEL, RB ;
PATEL, UR ;
ROGGE, MC ;
SHAH, VP ;
PRASAD, VK ;
SELEN, A ;
WELLING, PG .
JOURNAL OF PHARMACEUTICAL SCIENCES, 1984, 73 (03) :359-361
[10]   DETERMINATION OF PLASMA HYDROCHLOROTHIAZIDE LEVELS IN HUMANS [J].
REDALIEU, E ;
TIPNIS, VV ;
WAGNER, WE .
JOURNAL OF PHARMACEUTICAL SCIENCES, 1978, 67 (05) :726-728