ION-EXCHANGE OF CATIONIC DRUGS AT A NAFION-COATED ELECTRODE IN FLOW-THROUGH ANALYSIS

被引:26
|
作者
ZHOU, JX
WANG, E
机构
[1] Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun
基金
中国国家自然科学基金;
关键词
AMPEROMETRY; FLOW SYSTEM; VOLTAMMETRY; NAFION-COATED ELECTRODES; PHARMACEUTICALS; PROMETHAZINE;
D O I
10.1016/S0003-2670(00)83023-8
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Steady-state voltammetric and flow-through thin-layer amperometric experiments were done to investigate the influence of various preliminary experimental conditions on the selectivity of a Nafion-coated electrode in the flow-through determination of cationic drugs (promethiazine was selected as a model compound). From the results guidelines were formulated to obtain optimum selectivity for cationic drugs with a Nafion-coated electrode in flow-through analysis.
引用
收藏
页码:489 / 494
页数:6
相关论文
共 50 条
  • [41] MASS-TRANSFER ANALYSIS OF PERVAPORATION THROUGH AN ION-EXCHANGE MEMBRANE
    SCHAETZEL, P
    FAVRE, E
    NGUYEN, QT
    NEEL, J
    DESALINATION, 1993, 90 (1-3) : 259 - 276
  • [42] FLOW-THROUGH SANDWICH PVC MATRIX MEMBRANE-ELECTRODE FOR FLOW-INJECTION ANALYSIS
    ALEGRET, S
    ALONSO, J
    BARTROLI, J
    LIMA, JLFC
    MACHADO, AASC
    PAULIS, JM
    ANALYTICAL LETTERS PART A-CHEMICAL ANALYSIS, 1985, 18 (18): : 2291 - 2303
  • [43] ION SELECTIVITY AND ION-EXCHANGE KINETICS OF A PERCHLORATE ION-SELECTIVE ELECTRODE BASED ON AC IMPEDANCE ANALYSIS
    MASUDA, Y
    LIU, J
    SEKIDO, E
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1991, 313 (1-2): : 95 - 107
  • [44] ONLINE MONITORING WITH AN ION-SELECTIVE ELECTRODE IN A HIGH-VOLUME FLOW-THROUGH CELL
    BOND, AM
    HUDSON, HA
    VANDENBOSCH, PA
    WALTER, FL
    EXELBY, HRA
    ANALYTICA CHIMICA ACTA, 1982, 136 (APR) : 51 - 59
  • [45] Efficient analyte oxidation in an electrospray ion source using a porous flow-through electrode emitter
    Van Berkel, GJ
    Kertesz, V
    Ford, MJ
    Granger, MC
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2004, 15 (12) : 1755 - 1766
  • [46] Efficient analyte oxidation in an electrospray ion source using a porous flow-through electrode emitter
    Van Berkel, Gary J.
    Kertesz, Vilmos
    Ford, Michael J.
    Granger, Michael C.
    Journal of the American Society for Mass Spectrometry, 2004, 15 (12): : 1755 - 1766
  • [47] ALTERNATE WASHING METHOD FOR FLOW-THROUGH DETERMINATION OF AMMONIUM ION USING AN AMMONIA GAS ELECTRODE
    HARA, H
    MOTOIKE, A
    OKAZAKI, S
    ANALYTICAL CHEMISTRY, 1987, 59 (15) : 1995 - 1999
  • [48] Electrochemical Removal of Cesium Ions via Capacitive Deionization Using an Ion-Exchange Layer Coated on a Carbon Electrode
    Lee, Sang-Hun
    Choi, Mansoo
    Moon, Jei-Kwon
    Lee, Songbok
    Choi, Jihoon
    Kim, Seonbyeong
    APPLIED SCIENCES-BASEL, 2021, 11 (21):
  • [49] Mixed-mode reversed-phase and ion-exchange separations of cationic analytes on polybutadiene-coated zirconia
    Hu, Y
    Yang, XQ
    Carr, PW
    JOURNAL OF CHROMATOGRAPHY A, 2002, 968 (1-2) : 17 - 29
  • [50] New flow-through coulometric detector with renewable working electrode material for flow injection analysis and HPLC
    Mika, Jan
    Barek, Jiri
    Zima, Jiri
    Dejmkova, Hana
    ELECTROCHIMICA ACTA, 2015, 154 : 397 - 403