WHITE CELL-REDUCED RED-CELLS PREPARED BY FILTRATION - A CRITICAL-EVALUATION OF CURRENT FILTERS AND METHODS FOR COUNTING RESIDUAL WHITE CELLS

被引:51
|
作者
REBULLA, P [1 ]
PORRETTI, L [1 ]
BERTOLINI, F [1 ]
MARANGONI, F [1 ]
PRATI, D [1 ]
SMACCHIA, C [1 ]
PAPPALETTERA, M [1 ]
PARRAVICINI, A [1 ]
SIRCHIA, G [1 ]
机构
[1] OPED MAGGIORE,CTR TRANSFUS & IMMUNOL TRAPIANTI,MILAN,ITALY
关键词
D O I
10.1046/j.1537-2995.1993.33293158044.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
White cell (WBC) reduction, red cell (RBC) recovery, and filtration time were determined in 1-day-old standard and buffy coat-depleted RBCs filtered in the laboratory through six commercial filters for WBC reduction. Residual WBCs were counted with a Burker chamber (BC), with a Nageotte chamber (NC), and by flow cytometry (FC). Results show that BC counts were 0 in several cases in which WBCs were detected with NC and FC, which indicated that the traditional BC method is too insensitive in use with currently available filters. Calibration curves performed by FC and with NC with samples containing known concentrations of WBCs from 1000 to 1 per muL showed that both FC and NC detected, on average, 67 percent of WBCs present in the samples (efficiency). However, the efficiency of FC showed small variability (61-70%) at different WBC levels, whereas the variability with NC was large (39-91%). This greater variability prevented the correction of NC counts by using a single factor and indicated difficulty in NC standardization. Therefore, because our main aim was to compare different filters rather than to define absolute levels of WBC contamination, uncorrected FC and NC counts were chosen to be reported. True WBC counts per unit should not exceed values that can be obtained by dividing uncorrected counts by the lowest efficiencies (61% for FC and 39% for NC). Uncorrected NC and FC counts were below 2 x 10(6) per unit in all units processed through three of the filters and below 5 x 10(6) per unit in all units processed through the other three. Removal of the buffy coat from RBCs before filtration generally but not invariably caused slightly higher WBC removals. Median RBC recovery in CPD RBCs containing the buffy coat, filtered through four of the filters, was greater than 90 percent, which was significantly higher than that shown by the other two filters. Buffy coat removal prior to filtration involved an additional median loss of 12.4 percent of RBCs. Median filtration time ranged from 5 to 23 minutes per unit. Although NC appears to be less expensive than FC, its performance in experimental and routine conditions requires further evaluation and thorough standardization. Because of the continuous development of more effective filters, more sensitive methods for WBC counting in WBC-reduced blood components are needed.
引用
收藏
页码:128 / 133
页数:6
相关论文
共 50 条
  • [1] AN IMPROVED METHOD FOR WHITE CELL COUNTING IN WHITE CELL-REDUCED RED-CELLS
    PRATI, D
    CAPELLI, C
    BOSONI, P
    REBULLA, P
    TRANSFUSION, 1994, 34 (05) : 453 - 454
  • [2] DELAYED HEMOLYSIS OF WHITE CELL-REDUCED RED-CELLS
    CARSON, TH
    BLOOM, J
    FERGUSON, DB
    THOMPSON, S
    LEBEAU, B
    TRANSFUSION, 1994, 34 (01) : 86 - 86
  • [3] Quality control of white cell-reduced red cells: White cell preservation and simplified counting
    Tran, K
    Nakajo, S
    Kapoor, V
    Chen, M
    Stromberg, RR
    TRANSFUSION, 1998, 38 (05) : 429 - 433
  • [4] QUALITY-CONTROL OF WHITE CELL-REDUCED RED-CELLS - ENOUGH IS ENOUGH
    KOLINS, J
    TRANSFUSION, 1993, 33 (02) : 182 - 183
  • [5] CYTOKINE GENERATION IN STORED, WHITE CELL-REDUCED, AND BACTERIALLY CONTAMINATED UNITS OF RED-CELLS
    STACK, G
    BARIL, L
    NAPYCHANK, P
    SNYDER, EL
    TRANSFUSION, 1995, 35 (03) : 199 - 203
  • [7] PREPARATION OF WHITE CELL-REDUCED RED-CELLS BY FILTRATION - COMPARISON OF A BEDSIDE FILTER AND 2 BLOOD-BANK FILTER SYSTEMS
    SPROGOEJAKOBSEN, U
    SAETRE, AM
    GEORGSEN, J
    TRANSFUSION, 1995, 35 (05) : 421 - 426
  • [8] Automatic volumetric capillary cytometry for counting white cells in white cell-reduced plateletpheresis components
    Adams, MR
    Johnson, DK
    Busch, MP
    Schembri, CT
    Hartz, TP
    Heaton, WA
    TRANSFUSION, 1997, 37 (01) : 29 - 37
  • [9] CHARACTERISTICS OF WHITE CELL-REDUCED RED-CELLS STORED IN TRI-(2-ETHYLHEXYL)TRIMELLITATE PLASTIC
    DAVEY, RJ
    HEATON, WAL
    SWEAT, LT
    STEC, NM
    NELSON, EJ
    HOLME, S
    TRANSFUSION, 1994, 34 (10) : 895 - 898
  • [10] A MULTICENTER STUDY ON THE EFFICIENCY OF WHITE CELL REDUCTION BY FILTRATION OF RED-CELLS
    MASSE, M
    ANDREU, G
    ANGUE, M
    BABAULT, C
    BEAUJEAN, F
    BIDET, ML
    BOUDART, D
    CALOT, JP
    COTTE, C
    FOLLEA, G
    GEROTA, J
    HAU, F
    HUREL, C
    LEGRAND, E
    MARCHESSEAU, B
    NASR, O
    ROBERT, F
    ROYER, D
    SCHOONEMAN, F
    TARDIVEL, R
    VIDAL, M
    TRANSFUSION, 1991, 31 (09) : 792 - 797