To-and-fro waveform in the diagnosis of arterial pseudoaneurysms

被引:92
作者
Mahmoud, Mustafa Z. [1 ,2 ]
Al-Saadi, Mohammed [1 ]
Abuderman, Abdulwahab [3 ]
Alzimami, Khalid S. [4 ]
Alkhorayef, Mohammed [4 ]
Almagli, Babikir [5 ]
Sulieman, Abdelmoneim [1 ]
机构
[1] Prince Sattam bin Abdulaziz Univ, Coll Appl Med Sci, Radiol & Med Imaging Dept, POB 422, Al Kharj 11942, Saudi Arabia
[2] Sudan Univ Sci & Technol, Coll Med Radiol Sci, Basic Med Sci Dept, Khartoum 11111, Sudan
[3] Prince Sattam bin Abdulaziz Univ, Coll Med, Basic Med Sci Dept, Al Kharj 11942, Saudi Arabia
[4] King Saud Univ, Coll Appl Med Sci, Radiol Sci Dept, Riyadh 11433, Saudi Arabia
[5] Natl Ribat Univ, Fac Radiol & Nucl Med, Diagnost Radiol Dept, Khartoum 1111, Sudan
关键词
Pseudoaneurysm; To-and-fro waveform; Ultrasonography; Percutaneous thrombin injection; Yin-Yang sign;
D O I
10.4329/wjr.v7.i5.89
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Medical ultrasound imaging with Doppler plays an essential role in the diagnosis of vascular disease. This study intended to review the clinical use of "to-and-fro" waveform at duplex Doppler ultrasonography (DDU) in the diagnosis of pseudoaneurysms in the arterial vessels of upper and lower extremities, abdominal aorta, carotid and vertebral arteries as well as to review our personal experiences of "to-and-fro" waveform at DDU also. After receiving institutional review board approval, an inclusive literature review was carried out in order to review the scientific foundation of "to-and-fro" waveform at DDU and its clinical use in the diagnosis of pseudoaneurysms in various arterial vessels. Articles published in the English language between 2000 and 2013 were evaluated in this review study. Pseudoaneurysms in arterial vessels of the upper and lower extremities, abdominal aorta, carotid and vertebral arteries characterized by an extraluminal pattern of blood flow, which shows variable echogenicity, interval complexity, and "to-and-fro" flow pattern on color Doppler ultrasonography. In these arterial vessels, Duplex ultrasonography can demonstrate the degree of clotting, pseudoaneurysm communication, the blood flow patterns and velocities. Spectral Doppler applied to pseudoaneurysms lumen revealed systolic and diastolic turbulent blood flow with traditional "to-and-fro" waveform in the communicating channel. Accurate diagnosis of pseudoaneurysm by spectral Doppler is based on the documentation of the "to-and-fro" waveform. The size of pseudoaneurysm determines the appropriate treatment approach as surgical or conservative.
引用
收藏
页码:89 / 99
页数:11
相关论文
共 118 条
[1]   THE TO-AND-FRO SIGN - DUPLEX DOPPLER EVIDENCE OF FEMORAL-ARTERY PSEUDOANEURYSM [J].
ABUYOUSEF, MM ;
WIESE, JA ;
SHAMMA, AR .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1988, 150 (03) :632-634
[2]   Portable ultrasound to diagnose true radial artery aneurysm [J].
Barker, C. ;
Jefferson, P. ;
Ball, D. R. .
ANESTHESIA AND ANALGESIA, 2007, 105 (03) :890-891
[3]  
Bergan J, 1982, ANEURYSMS DIAGNOSIS
[4]  
Bernik Thomas R, 2002, Vasc Endovascular Surg, V36, P461, DOI 10.1177/153857440203600607
[5]   Iatrogenic femoral pseudoaneurysms: Thrombin injection after failed US-guided compression [J].
Brophy, DP ;
Sheiman, RG ;
Amatulle, P ;
Akbari, CM .
RADIOLOGY, 2000, 214 (01) :278-282
[6]   Distinguishing left ventricular aneurysm from pseudoaneurysm - A review of the literature [J].
Brown, SL ;
Gropler, RJ ;
Harris, KM .
CHEST, 1997, 111 (05) :1403-1409
[7]   Percutaneous thrombin injection for pseudoaneurysm treatment [J].
Bydawell, G. .
SA JOURNAL OF RADIOLOGY, 2013, 17 (01) :41-42
[8]   A true aneurysm of the tibioperoneal trunk. Case report and literature review [J].
Cappendijk, VC ;
Mouthaan, PJ .
EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 1999, 18 (06) :536-537
[9]  
Carrafiello G, 2006, INJURY EXTRA, V37, P78, DOI [10.1016/j.injury.2005.08.012, DOI 10.1016/J.INJURY.2005.08.012]
[10]  
Carroll BA, 1992, PERIPHERAL VASCULAR, P211