Icare (R) rebound tonometers: review of their characteristics and ease of use

被引:54
作者
Nakakura, Shunsuke [1 ]
机构
[1] Saneikai Tsukazaki Hosp, Dept Ophthalmol, 68-1 Aboshi Waku, Himeji, Hyogo 6711227, Japan
关键词
rebound tonometer; intraocular pressure; glaucoma; Icare;
D O I
10.2147/OPTH.S163092
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
The rebound tonometer has a unique mechanism for measuring intraocular pressure (IOP) and has become popular worldwide due to its ease of use. The most notable advantages are the lack of an air-puff and need for topical anesthesia, ease of operation and transport, and the ability to use it with children. Four rebound tonometers (Icare (R) TA01i, Icare PRO, Icare HOME, and Icare ic100) are currently available for clinical examination. It is important to understand the characteristics of each tonometer and select the most appropriate one because the IOP values and the purpose of measurement are different. In this review, with the goal of improving the understanding of a range of tonometers, the issues with each device are discussed.
引用
收藏
页码:1245 / 1253
页数:9
相关论文
共 37 条
[1]  
ARMALY MF, 1961, ARCH OPHTHALMOL-CHIC, V65, P415
[2]  
Baek SU, BR J OPHTHALMOL
[3]   Does Rebound Tonometry Probe Misalignment Modify Intraocular Pressure Measurements in Human Eyes? [J].
Beasley, Ian G. ;
Laughton, Deborah S. ;
Coldrick, Benjamin J. ;
Drew, Thomas E. ;
Sallah, Marium ;
Davies, Leon N. .
JOURNAL OF OPHTHALMOLOGY, 2013, 2013
[4]   Collagen fibrils appear more closely packed in the prepupillary cornea: Optical and biomechanical implications [J].
Boote, C ;
Dennis, S ;
Newton, RH ;
Puri, H ;
Meek, KM .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2003, 44 (07) :2941-2948
[5]   Self-tonometry as a complement in the investigation of glaucoma patients [J].
Chen, Enping ;
Querat, Laurence ;
Akerstedt, Christina .
ACTA OPHTHALMOLOGICA, 2016, 94 (08) :788-792
[6]   The influence of cornea properties on rebound tonometry [J].
Chui, Wan-sang ;
Lam, Andrew ;
Chen, Davie ;
Chiu, Roger .
OPHTHALMOLOGY, 2008, 115 (01) :80-84
[7]   Evaluation of a new rebound tonometer for self-measurement of intraocular pressure [J].
Dabasia, Priya L. ;
Lawrenson, John G. ;
Murdoch, Ian E. .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2016, 100 (08) :1139-1143
[8]   Accuracy of the new ICare rebound tonometer vs. other portable tonometers in healthy eyes [J].
García-Resúa, C ;
González-Meijome, JM ;
Gilino, J ;
Yebra-Pimentel, E .
OPTOMETRY AND VISION SCIENCE, 2006, 83 (02) :102-107
[9]   Age differences in central and peripheral intraocular pressure using a rebound tonometer [J].
Gonzalez-Meijome, J. M. ;
Jorge, J. ;
Queiros, A. ;
Fernandes, P. ;
Montes-Mico, R. ;
Almeida, J. B. ;
Parafita, M. A. .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2006, 90 (12) :1495-1500
[10]   Dynamic corneal imaging [J].
Grabner, G ;
Ellmsteiner, R ;
Steindl, C ;
Ruckhofer, J ;
Mattioli, R ;
Husinsky, W .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2005, 31 (01) :163-174