Inhalation drug delivery devices: technology update

被引:246
作者
Ibrahim, Mariam [1 ]
Verma, Rahul [1 ]
Garcia-Contreras, Lucila [1 ]
机构
[1] Univ Oklahoma, Coll Pharm, Hlth Sci Ctr, Dept Pharmaceut Sci, Oklahoma City, OK 73126 USA
关键词
pulmonary delivery; asthma; nebulizers; metered dose inhaler; dry powder inhaler;
D O I
10.2147/MDER.S48888
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The pulmonary route of administration has proven to be effective in local and systemic delivery of miscellaneous drugs and biopharmaceuticals to treat pulmonary and nonpulmonary diseases. A successful pulmonary administration requires a harmonic interaction between the drug formulation, the inhaler device, and the patient. However, the biggest single problem that accounts for the lack of desired effect or adverse outcomes is the incorrect use of the device due to lack of training in how to use the device or how to coordinate actuation and aerosol inhalation. This review summarizes the structural and mechanical features of aerosol delivery devices with respect to mechanisms of aerosol generation, their use with different formulations, and their advantages and limitations. A technological update of the current state-of-the-art designs proposed to overcome current challenges of existing devices is also provided.
引用
收藏
页码:131 / 139
页数:9
相关论文
共 81 条
[61]  
Sanders Mark, 2007, Prim Care Respir J, V16, P71, DOI 10.3132/pcrj.2007.00017
[62]  
Simis K, 2008, DRUG DEV IND PHARM, V34, P936, DOI [10.1080/03639040802149061, 10.1080/03639040802149061 ]
[63]   Omron NE U22: Comparison Between Vibrating Mesh and Jet Nebulizer [J].
Skaria, Shibu ;
Smaldone, Gerald C. .
JOURNAL OF AEROSOL MEDICINE AND PULMONARY DRUG DELIVERY, 2010, 23 (03) :173-180
[64]   The influence of formulation variables on the performance of alternative propellant-driven metered dose inhalers [J].
Smyth, HDC .
ADVANCED DRUG DELIVERY REVIEWS, 2003, 55 (07) :807-828
[65]  
Smyth Hugh D C, 2005, Expert Opin Drug Deliv, V2, P53, DOI 10.1517/17425247.2.1.53
[66]   Metered-dose inhaler add-on devices: An in vitro evaluation of the BronchoAir inhaler and several spacer devices [J].
Steckel, H ;
Muller, BW .
JOURNAL OF AEROSOL MEDICINE-DEPOSITION CLEARANCE AND EFFECTS IN THE LUNG, 1998, 11 (03) :133-142
[67]   Advances in Metered Dose Inhaler Technology: Hardware Development [J].
Stein, Stephen W. ;
Sheth, Poonam ;
Hodson, P. David ;
Myrdal, Paul B. .
AAPS PHARMSCITECH, 2014, 15 (02) :326-338
[68]   Qualitative assessment of attributes and ease of use of the ELLIPTA™ dry powder inhaler for delivery of maintenance therapy for asthma and COPD [J].
Svedsater, Henrik ;
Dale, Peter ;
Garrill, Karl ;
Walker, Richard ;
Woepse, Mark W. .
BMC PULMONARY MEDICINE, 2013, 13
[69]  
Systems MDD, 2011, DEV EFF DRY POWD INH
[70]  
Systems MDD, 2011, COMP PERF 3MTM TAP D