A SIMPLE-MODEL FOR TRANSFORMER INRUSH CURRENT CALCULATION AND HARMONIC-ANALYSIS

被引:4
|
作者
CHENG, CL
LIN, CE
HUANG, CL
YEH, JC
机构
[1] Department of Electrical Engineering, Yunlin Polytechnic Institute, Yunlin
[2] Department of Electrical Engineering, Cheng Kung University, Tainan
关键词
INRUSH CURRENT; HARMONIC ANALYSIS; NUMERICAL SIMULATION; REAL-TIME MEASUREMENTS;
D O I
10.1016/0378-7796(92)90084-E
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Measurements of transformer inrush current offer important data for power system operation and protection. Since inrush current is the result of a system transient, it is difficult to observe this phenomenon and analyze its effect instantaneously. This paper proposes a simple model to represent and simulate the magnetizing inrush current of transformers using real-time measurements. The proposed method formulates a simplified model to represent the inrush current under different loading conditions. The simulation data are also used for harmonic analysis. The relationship of the harmonics to all parameters is discussed. The proposed simulation results are compared with the experimental results with very good agreement. The results establish a guideline for elimination of harmonics due to inrush current, and offer an important reference for system design considerations.
引用
收藏
页码:153 / 163
页数:11
相关论文
共 50 条
  • [21] MODEL ERRORS OF THE SPHERICAL HARMONIC-ANALYSIS
    GOLOVKOV, VP
    ZVEREVA, TI
    GEOMAGNETIZM I AERONOMIYA, 1989, 29 (06): : 1007 - 1012
  • [22] Voltage Drop Calculation Considering Transformer Inrush Current with EDG Operation
    Heo, Jeong-Hyeok
    Kim, Seong-Il
    Kim, Joon-Ho
    Kim, Soo-Nam
    2015 3RD INTERNATIONAL CONFERENCE ON ELECTRIC POWER EQUIPMENT - SWITCHING TECHNOLOGY (ICEPE-ST), 2015, : 455 - 458
  • [23] Harmonic analysis of transformer inrush currents under loading conditions
    Huang, Ching-Lien
    Cheng, Cheng-Long
    Lin, Chin E.
    Yeh, Jim-Chwen
    Proceedings of the National Science Council, Republic of China, Part A: Physical Science and Engineering, 1992, 16 (05): : 422 - 429
  • [24] A SIMPLE-MODEL FOR THE CALCULATION OF SELF-DIFFUSION
    TANKESHWAR, K
    SINGLA, B
    PATHAK, KN
    JOURNAL OF PHYSICS-CONDENSED MATTER, 1991, 3 (18) : 3173 - 3182
  • [25] Analysis of sample current based on harmonic restraint inrush current
    Zheng, Yuping
    Liu, Xiaobao
    Zhang, Zhe
    Pan, Shuyan
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2011, 35 (18): : 87 - 91
  • [26] ANALYSIS OF OVERVOLTAGES CAUSED BY TRANSFORMER MAGNETIZING INRUSH CURRENT
    POVH, D
    SCHULTZ, W
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1978, 97 (04): : 1355 - 1365
  • [27] Analysis on the Influencing Factors of Transformer Sympathetic Inrush Current
    Wang, Yangguang
    Yin, Xianggen
    You, Dahai
    Xu, Tianqi
    2008 IEEE POWER & ENERGY SOCIETY GENERAL MEETING, VOLS 1-11, 2008, : 2150 - 2157
  • [28] Analytical Analysis of Transformer Interaction Caused by Inrush Current
    Heretik, P.
    Kovac, M.
    Belan, A.
    Volcko, V.
    Konicek, M.
    PROCCEDINGS OF THE 2014 15TH INTERNATIONAL SCIENTIFIC CONFERENCE ON ELECTRIC POWER ENGINEERING (EPE), 2014,
  • [29] Calculation of residual flux based on Preisach model and entering phase control of transformer to eliminate inrush current
    Wuyun, Gaowa
    Liu, dichen
    Li, Po
    CEEM' 2006: Asia-Pacific Conference on Environmental Electromagnetics, Vols 1 and 2, Proceedings, 2006, : 396 - 401
  • [30] SIMPLE-MODEL OF 2ND-HARMONIC GENERATION
    SCHAICH, WL
    MENDOZA, BS
    PHYSICAL REVIEW B, 1992, 45 (24): : 14279 - 14292