A CARBON-FIBER IMPLANT TO AID INTERBODY LUMBAR FUSION - MECHANICAL TESTING

被引:127
作者
BRANTIGAN, JW
STEFFEE, AD
GEIGER, JM
机构
[1] Cleveland Spine Arthritis Center, Cleveland, OH
[2] Cleveland Research Institute, Cleveland, OH
关键词
POSTERIOR LUMBAR INTERBODY FUSION; INTERBODY FUSION; INSTABILITY; ANTERIOR COLUMN; SPINE IMPLANT;
D O I
10.1097/00007632-199106001-00020
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
A carbon-fiber-reinforced polymer implant has been designed to aid interbody lumbar fusion. The cage-like implant has ridges or teeth to resist pullout or retropulsion, struts to support weight bearing, and a hollow center for packing of autologous bone graft. Because carbon is radiolucent, bony healing can be imaged by standard radiographic techniques. The device has been mechanically tested in cadaver spines and compared with posterior lumbar interbody fusion performed with donor bone. The carbon device required a pullout force of 353 N compared with 126 N for donor bone. In compression testing, posterior lumbar interbody fusion performed with the carbon device bore a load of 5,288 N before failure of the vertebral bone. Posterior lumbar interbody fusion performed with donor bone failed at 4,628 N, and unmodified motion segments failed at 6,043 N. The carbon fiber implant separates the mechanical and biologic functions of posterior lumbar interbody fusion.
引用
收藏
页码:S277 / S282
页数:6
相关论文
共 23 条
  • [1] Adams D., Williams D.F., Carbon fiber-reinforced carbon as a potential implant material, J Biomed Mater Res, 12, pp. 35-42, (1978)
  • [2] Collis J.S., Total disc replacement: A modified posterior lumbar interbody fusion, Clinorthop, 193, pp. 64-67, (1985)
  • [3] Cloward R.B., The treatment of ruptured lumbar intervertebral discs by vertebral body fusion, J Neurosurg, 10, (1953)
  • [4] Cloward R.B., Posterior lumbar interbody fusion updated, Clin Orthop, 193, pp. 16-19
  • [5] Evans J.H., Biomechanics of lumbar fusion, Clin Orthop, 193, pp. 38-56, (1985)
  • [6] Friedlaender G.E., Current concepts review: Bone grafts, J Bone Joint Surg, 69A, pp. 786-789, (1987)
  • [7] Herron L.D., Newman M., The failure of ethylene oxide gas-sterilized freeze-dried bone graft for thoracic and lumbar spinal fusions, Spine, 14, pp. 496-500, (1989)
  • [8] Holiday A.D., Asher M.A., Erson H.C., The sterilization of bank bone, Unpublished Manuscript
  • [9] Hutter C.G., Spinal stenosis and posterior lumbar interbody fusion, Clin Orthop, 193, pp. 103-114, (1985)
  • [10] Jenkins G.M., Grigson C.G., The fabrication of artifacts out of glassy carbon and carbon-fiber reinforced carbon for biomedical applications, J Biomed Mater Res, 13, pp. 371-394, (1979)