Surgical Management of Tibial Plateau Fractures With 3.5 mm Simple Plates

被引:6
作者
Bagherifard, Abolfazl [1 ]
Jabalameli, Mahmoud [1 ]
Hadi, Hosseinali [1 ]
Rahbar, Mohammad [1 ]
Sajjadi, Mohammadreza Minator [2 ]
Jahansouz, Ali [1 ]
Heris, Hossein Karimi [1 ]
机构
[1] Iran Univ Med Sci, Shafa Orthoped Hosp, Bone & Joint Reconstruct Res Ctr, Tehran, Iran
[2] Shahid Beheshti Univ Med Sci, Taleghani Hosp Res Dev Unit, Tehran, Iran
关键词
Fracture; Osteosynthesis; Tibial Plateau; Internal Fixation;
D O I
10.5812/traumamon.26733
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background: Tibial plateau fractures can be successfully fixed utilizing 3.5 mm locking plates. However, there are some disadvantages to using these plates. Objectives: In the current prospective study, we investigated the outcome of treating different types of tibial plateau fractures with 3.5 mm simple plates which, to our knowledge, has not been evaluated in previous studies. Materials and Methods: Between 2011 and 2013, 32 patients aged 40 +/- 0.2 years underwent open reduction and internal fixation for tibial plateau fractures with 3.5 mm simple plates. The patients were followed for 16.14 +/- 2.1 months. At each patient's final visit, the articular surface depression, medial proximal tibial angle, and slope angle were measured and compared with measurements taken early after the operation. The functional outcomes were measured with the WOMAC and Lysholm knee scores. Results: The mean union time was 13 +/- 1.2 weeks. The mean knee range of motion was 116.8 degrees +/- 3.3 degrees. The mean WOMAC and Lysholm scores were 83.5 +/- 1.8 and 76.8 +/- 1.6, respectively. On the early postoperative and final X-rays, 87.5% and 84% of patients, respectively, had acceptable reduction. Medial proximal tibial and slope angles did not change significantly by the last visit. No patient was found to have complications related to the type of plate. Conclusions: In this case series study, the fixation of different types of tibial plateau fractures with 3.5 mm simple non-locking and non-precontoured plates was associated with acceptable clinical, functional, and radiographic outcomes. Based on the advantages and costs of these plates, the authors recommend using 3.5 mm simple plates for different types of tibial plateau fractures.
引用
收藏
页数:6
相关论文
共 34 条
[1]   Experimental model of tibial plateau fracture for biomechanical testing [J].
Ali, Ahmad M. ;
Saleh, Michael ;
Bolongaro, Stefano ;
Yang, Lang .
JOURNAL OF BIOMECHANICS, 2006, 39 (07) :1355-1360
[2]  
Andrews J R, 1992, Orthop Rev, V21, P317
[3]  
Baima J, 2008, CURR REV MUSCULOSKE, V1, P147, DOI 10.1007/s12178-008-9023-6
[4]   THE RESULTS OF SURGICAL-MANAGEMENT OF DISPLACED TIBIAL PLATEAU FRACTURES IN THE ELDERLY [J].
BIYANI, A ;
REDDY, NS ;
CHAUDHURY, J ;
SIMISON, AJM ;
KLENERMAN, L .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 1995, 26 (05) :291-297
[5]  
BLOKKER CP, 1984, CLIN ORTHOP RELAT R, P193
[6]   Nonunions around the knee joint [J].
Chan, Daniel B. ;
Jeffcoat, Devon M. ;
Lorich, Dean G. ;
Helfet, David L. .
INTERNATIONAL ORTHOPAEDICS, 2010, 34 (02) :271-281
[7]   Functional outcome of tibial plateau fractures treated with the fine-wire fixator [J].
Chin, TYP ;
Bardana, D ;
Bailey, M ;
Williamson, OD ;
Miller, R ;
Edwards, ER ;
Esser, MP .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2005, 36 (12) :1467-1475
[8]   Treatment of proximal tibia fractures using the Less Invasive Stabilization System - Surgical experience and early clinical results in 77 fractures [J].
Cole, PA ;
Zlowodzki, M ;
Kregor, PJ .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2004, 18 (08) :528-535
[9]  
DECOSTER TA, 1988, CLIN ORTHOP RELAT R, P196
[10]   Staged management of high-energy proximal tibia fractures (OTA types 41) - The results of a prospective, standardized protocol [J].
Egol, KA ;
Tejwani, NC ;
Capla, EL ;
Wolinsky, PL ;
Koval, KJ .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2005, 19 (07) :448-455