CALORIC IRRIGATORS - AIR, OPEN-LOOP WATER AND CLOSED-LOOP WATER

被引:8
作者
ANDERSON, S
机构
来源
BRITISH JOURNAL OF AUDIOLOGY | 1995年 / 29卷 / 02期
关键词
CALORIC TEST INSTRUMENTATION; REPRODUCIBILITY OF RESULTS; CLOSED-LOOP IRRIGATOR; AIR IRRIGATOR;
D O I
10.3109/03005369509086589
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
Selective stimulation of the semicircular canal system of one ear by establishing a temperature gradient is still widely used in the clinic in the caloric test. The results obtained are noted for their imprecision and variability. This is, in part, due to a lack of uniformly applied standardized test protocols, as well as difficulties in applying a precise stimulus. The relative merit of the three types of irrigation are reviewed. Whilst some authors argue that both the closed-loop and air irrigators produce even more Variability of response than open water systems, the present author believes that intratest replication studies indicate that the closed-loop irrigation stimulus is the least variable and best tolerated by the patient. In perhaps one-fifth of patients, response to the first irrigation is much stronger than subsequent stimulus applications. It is suggested that there may therefore be a case for routinely performing five irrigations in the bithermal caloric test, including a replication of the first irrigation. It is assumed that psychological factors, especially anxiety, may explain the phenomenon of enhanced initial response, and some of the variability of caloric test responses in general. Use of the closed-loop irrigator is advocated for ease of user reduced routine maintenance and to minimize patient distress, thereby reducing anxiety and result variability.
引用
收藏
页码:117 / 128
页数:12
相关论文
共 44 条
[1]  
AANTAA E, 1967, ACTA OTO-LARYNGOL, V224, P82
[2]  
ASCHAN G, 1956, Acta Otolaryngol Suppl, V129, P1
[3]  
BALOH RW, 1977, ANN OTO RHINOL LARYN, V86, P1
[4]  
BARBER HO, 1978, LARYNGOSCOPE, V88, P1117
[5]   AIR CALORICS - TECHNIQUE AND RESULTS [J].
BENITEZ, JT ;
BOUCHARD, KR ;
CHOE, YK .
ANNALS OF OTOLOGY RHINOLOGY AND LARYNGOLOGY, 1978, 87 (02) :216-223
[6]  
BROOKLER KH, 1991, AM J OTOL, V12, P480
[7]   SIMULTANEOUS BINAURAL BITHERMAL - CALORIC TEST UTILIZING ELECTRONYSTAGMOGRAPHY [J].
BROOKLER, KH .
LARYNGOSCOPE, 1976, 86 (08) :1241-1250
[8]   SIMULTANEOUS BILATERAL BITHERMAL CALORIC STIMULATION IN ELECTRONYSTAGMOGRAPHY [J].
BROOKLER, KH .
LARYNGOSCOPE, 1971, 81 (07) :1014-&
[9]   CLOSED-LOOP WATER IRRIGATOR SYSTEM [J].
BROOKLER, KH ;
BAKER, AH ;
GRAMS, G .
OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 1979, 87 (03) :364-365
[10]  
BROOKLER KH, 1983, OPTOKINETIC TESTS, P160