A SYSTEM MODEL FOR CLOSED-CIRCUIT INHALATION ANESTHESIA .1. COMPUTER STUDY

被引:32
|
作者
LEROU, JGC
DIRKSEN, R
KOLMER, HHB
BOOIJ, LHDJ
机构
[1] University of Nijmegen, Institute for Anesthesiology, 6500 HB Nijmegen
关键词
ANESTHETIC TECHNIQUES; CLOSED-CIRCUIT; ANESTHETIC GASES; NITROUS OXIDE; ANESTHETICS; VOLATILE; ISOFLURANE; ENFLURANE; COMPUTER; SIMULATION; MODELS; PROGRAMMING LANGUAGES; PHARMACOKINETICS; UPTAKE; DISTRIBUTION;
D O I
10.1097/00000542-199108000-00025
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Developing a custom computer program to simulate the uptake, distribution, and elimination of inhalational anesthetics allows the anesthesiologist to address specific problems, but extensive skills are required to translate the involved processes first into a set of mathematical equations and then into a satisfactory computer program. The first step is often facilitated by solutions offered in the literature. The second step demands computer proficiency that is often not available, but this problem can be obviated by means of a special-purpose simulation language (SPSL). We therefore constructed a model for closed-circuit inhalation anesthesia with the aid of the block-structured SPSL TUTSIM(R). Noticeable differences with previous models are that the linear, 14-compartment basic model does not assume a constant alveolar concentration and mimics circulation times through the use of blood pools. Advanced features of the SPSL were used to develop variants of the basic model to simulate feedback-controlled isoflurane administration, nitrous oxide uptake, and the impact of a nonlinearity by incorporating the effect of enflurane on cardiac output. Two variants were concatenated to form a multiple model showing the concentration and second-gas effects. The model was capable of reproducing the anesthetic uptake from previous experimental studies for nitrous oxide. After its validation for other anesthetic agents, the model can be used for clinical, teaching, and research purposes. The SPSL freed the authors from the problems associated with computer programming and allowed them to concentrate on the structure of the model.
引用
收藏
页码:345 / 355
页数:11
相关论文
共 50 条
  • [1] PHARMACOKINETIC MODEL OF CLOSED-CIRCUIT INHALATION ANESTHESIA
    GOLDBERG, IS
    MOSTERT, JW
    LANZL, EF
    LOWE, HJ
    ANNALS OF BIOMEDICAL ENGINEERING, 1978, 6 (03) : 231 - 249
  • [2] A SYSTEM MODEL FOR CLOSED-CIRCUIT INHALATION ANESTHESIA .2. CLINICAL VALIDATION
    LEROU, JGC
    DIRKSEN, R
    KOLMER, HHB
    BOOIJ, LHDJ
    BORM, GF
    ANESTHESIOLOGY, 1991, 75 (02) : 230 - 237
  • [3] CLOSED-CIRCUIT ANESTHESIA
    BEATTY, PCW
    KAY, B
    BRITISH JOURNAL OF ANAESTHESIA, 1984, 56 (08) : 928 - 928
  • [4] CLOSED-CIRCUIT ANESTHESIA
    FOSTER, PA
    SOUTH AFRICAN MEDICAL JOURNAL, 1974, 48 (16): : 701 - 704
  • [5] CLOSED-CIRCUIT ANESTHESIA
    NUNN, JF
    BRITISH JOURNAL OF ANAESTHESIA, 1978, 50 (08) : 733 - 734
  • [6] CLOSED-CIRCUIT ANESTHESIA
    BURNS, THS
    ANAESTHESIA, 1980, 35 (11) : 1114 - 1115
  • [7] THE PREDICTIVE PERFORMANCE OF A SYSTEM MODEL FOR ENFLURANE CLOSED-CIRCUIT INHALATIONAL ANESTHESIA
    LEROU, JGC
    VERMEULEN, PM
    DIRKSEN, R
    BOOIJ, LHDJ
    BORM, GF
    ANESTHESIOLOGY, 1993, 79 (05) : 932 - 942
  • [8] VERY NEARLY CLOSED-CIRCUIT ANESTHESIA - COMPUTER-ANALYSIS
    HOLMES, CM
    SPEARS, GFS
    ANAESTHESIA, 1977, 32 (09) : 846 - 851
  • [9] COMPUTERIZED ANESTHESIA IN CLOSED-CIRCUIT
    MANGANAS, M
    OSSART, M
    ANESTHESIOLOGY, 1994, 81 (3A) : A577 - A577
  • [10] A SYSTEM MODEL FOR HALOTHANE CLOSED-CIRCUIT ANESTHESIA - STRUCTURE CONSIDERATIONS AND PERFORMANCE EVALUATION
    VERMEULEN, PM
    LEROU, JGC
    DIRKSEN, R
    BOOIJ, LHDJ
    BORM, GF
    ANESTHESIOLOGY, 1995, 83 (03) : 515 - 527