QUANTITATIVE-ANALYSIS OF MULTISLICE GD-DTPA ENHANCED DYNAMIC MR-IMAGES USING AN AUTOMATED SIMPLEX MINIMIZATION PROCEDURE

被引:85
作者
BUCKLEY, DL [1 ]
KERSLAKE, RW [1 ]
BLACKBAND, SJ [1 ]
HORSMAN, A [1 ]
机构
[1] UNIV NOTTINGHAM HOSP,MRI UNIT,NOTTINGHAM,ENGLAND
关键词
DYNAMIC MRI; GD-DTPA; SIMPLEX MINIMIZATION; BREAST NEOPLASM;
D O I
10.1002/mrm.1910320514
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Quantitative analysis of Gd-DTPA enhanced dynamic MR images has potential for discriminating lesions, especially because the introduction of clinical fast imaging techniques has enabled good sampling of the relatively rapid Gd-DTPA wash-in curves. Analysis of such data requires curve fitting to a nonlinear model, which to date has been performed using a nonlinear least squares (NLLS) fitting procedure. However, this method often fails to converge to the appropriate minima without good initial parameter estimates when multi-exponential models are involved, making automated analysis of complete multislice or volume data sets problematic. In this report we demonstrate the robust performance of a simplex minimization procedure compared with NLLS, by the method of Marquardt, using a Monte Carlo simulation. Further, we illustrate the applicability of such a technique to the analysis of dynamic contrast enhanced images on a pixel-by-pixel basis. As a preliminary example, the technique is applied to a breast lesion but is expected to be suitable for examination of many lesion types.
引用
收藏
页码:646 / 651
页数:6
相关论文
共 29 条
[1]  
[Anonymous], 1969, DATA REDUCTION ERROR
[2]  
BERKOWITZ BA, 1992, INVEST OPHTH VIS SCI, V33, P3500
[3]   PHARMACOKINETIC PARAMETERS IN CNS GD-DTPA ENHANCED MR IMAGING [J].
BRIX, G ;
SEMMLER, W ;
PORT, R ;
SCHAD, LR ;
LAYER, G ;
LORENZ, WJ .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1991, 15 (04) :621-628
[4]  
BUCKLEY DL, 1994, 1ST P NOTT S MAGN RE, P34
[5]  
BYDDER GM, 1988, MAGNETIC RESONANCE I, P182
[6]   MULTIEXPONENTIAL ANALYSIS OF RELAXATION DECAYS [J].
CLAYDEN, NJ ;
HESLER, BD .
JOURNAL OF MAGNETIC RESONANCE, 1992, 98 (02) :271-282
[7]   GADOLINIUM-DTPA AS A CONTRAST AGENT IN MR IMAGING - THEORETICAL PROJECTIONS AND PRACTICAL OBSERVATIONS [J].
GADIAN, DG ;
PAYNE, JA ;
BRYANT, DJ ;
YOUNG, IR ;
CARR, DH ;
BYDDER, GM .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1985, 9 (02) :242-251
[8]  
Gans P., 1992, DATA FITTING CHEM SC
[9]   DYNAMIC STUDIES OF GADOLINIUM UPTAKE IN BRAIN-TUMORS USING INVERSION-RECOVERY ECHO-PLANAR IMAGING [J].
GOWLAND, P ;
MANSFIELD, P ;
BULLOCK, P ;
STEHLING, M ;
WORTHINGTON, B ;
FIRTH, J .
MAGNETIC RESONANCE IN MEDICINE, 1992, 26 (02) :241-258
[10]  
GRIBBESTAD IS, 1993, 12TH P SMRM ANN M NE, P854