AN EXPERIMENTAL-STUDY IN ELECTRICAL-IMPEDANCE TOMOGRAPHY USING BACKPROJECTION RECONSTRUCTION

被引:34
|
作者
GUARDO, R
BOULAY, C
MURRAY, B
BERTRAND, M
机构
[1] Institut de Génie Biomedical, Ecole Polytechnique et Université de Montréal, Montréal, Québec
关键词
APPLIED POTENTIAL TOMOGRAPHY;
D O I
10.1109/10.83560
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This paper reports on experiments designed to evaluate the performance of the equipotentials backprojection method under conditions modeling those of proposed applications of electrical impedance tomography. Small spherical targets were placed inside a saline-filled tank with dimensions similar to a human torso. Data were acquired with a computer-based instrument that applies current to pairs of electrodes located on two horizontal planes and records potential differences between electrodes of a third plane. The relative contrast produced by nonconducting spheres in a uniform saline background was measured on the reconstructed images and used to determine system sensitivity to target volume and to the radial and vertical positions of single spheres. Results show that for radial positions within a critical radius sensitivity is always maximum when the spheres center is on the recording plane and decreases gradually when the target is moved outside this plane. Localization of simple targets in 3-D, with data acquired from multiple recording planes, appears feasible. The results provide guidelines for the interpretation of images with complex 3-D conductivity distributions.
引用
收藏
页码:617 / 627
页数:11
相关论文
共 50 条
  • [41] SPECTRAL EXPANSION ANALYSIS IN ELECTRICAL-IMPEDANCE TOMOGRAPHY
    ZADEHKOOCHAK, M
    BLOTT, BH
    HAMES, TK
    GEORGE, RF
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 1991, 24 (11) : 1911 - 1916
  • [42] OPTIMIZING THE TIME TO SOLUTION IN ELECTRICAL-IMPEDANCE TOMOGRAPHY
    FULTON, WS
    LIPCZYNSKI, RT
    IEE PROCEEDINGS-SCIENCE MEASUREMENT AND TECHNOLOGY, 1995, 142 (06) : 433 - 441
  • [43] DETECTION OF GASTROESOPHAGEAL REFLUX BY ELECTRICAL-IMPEDANCE TOMOGRAPHY
    RAVELLI, AM
    MILLA, PJ
    JOURNAL OF PEDIATRIC GASTROENTEROLOGY AND NUTRITION, 1994, 18 (02): : 205 - 213
  • [44] ELECTRICAL-IMPEDANCE TOMOGRAPHY - A REVIEW OF CURRENT LITERATURE
    JONGSCHAAP, HCN
    WYTCH, R
    HUTCHISON, JMS
    KULKARNI, V
    EUROPEAN JOURNAL OF RADIOLOGY, 1994, 18 (03) : 165 - 174
  • [45] THE IMPORTANCE OF PHASE MEASUREMENT IN ELECTRICAL-IMPEDANCE TOMOGRAPHY
    GRIFFITHS, H
    PHYSICS IN MEDICINE AND BIOLOGY, 1987, 32 (11): : 1435 - 1444
  • [46] A TRANSPUTER IMPLEMENTED ALGORITHM FOR ELECTRICAL-IMPEDANCE TOMOGRAPHY
    ZADEHKOOCHAK, M
    HAMES, TK
    BLOTT, BH
    GEORGE, RF
    CLINICAL PHYSICS AND PHYSIOLOGICAL MEASUREMENT, 1990, 11 (03): : 223 - 230
  • [47] FAST, NONLINEAR INVERSION FOR ELECTRICAL-IMPEDANCE TOMOGRAPHY
    PAULSON, K
    LIONHEART, W
    PIDCOCK, M
    IMAGE AND VISION COMPUTING, 1994, 12 (06) : 367 - 373
  • [48] ELECTRICAL-IMPEDANCE TOMOGRAPHY WITH PIECEWISE POLYNOMIAL CONDUCTIVITIES
    YORKEY, TJ
    JOURNAL OF COMPUTATIONAL PHYSICS, 1990, 91 (02) : 344 - 360
  • [49] ELECTRICAL-IMPEDANCE IMAGING OF THE BODY WITH NONLINEAR RECONSTRUCTION
    KIM, YM
    TOMPKINS, WJ
    WEBSTER, JG
    PROCEEDINGS OF THE SOCIETY OF PHOTO-OPTICAL INSTRUMENTATION ENGINEERS, 1983, 419 : 289 - 296
  • [50] CLINICAL IMPLEMENTATION OF ELECTRICAL-IMPEDANCE TOMOGRAPHY WITH HYPERTHERMIA
    MOSKOWITZ, MJ
    RYAN, TP
    PAULSEN, KD
    MITCHELL, SE
    INTERNATIONAL JOURNAL OF HYPERTHERMIA, 1995, 11 (02) : 141 - 149