Imageless navigation total hip arthroplasty - an evaluation of operative time

被引:13
作者
Valsamis, Epaminondas Markos [1 ]
Ricketts, David [1 ]
Hussain, Adnan [2 ]
Jenabzadeh, Amir-Reza [2 ]
机构
[1] Brighton & Sussex Univ Hosp, Brighton BN2 5BE, E Sussex, England
[2] Hinchingbrooke Hosp NHS Trust, Huntingdon PE29 6NT, England
关键词
Imageless navigation; Hip; Arthroplasty; Operative time;
D O I
10.1051/sicotj/2018016
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction: Imageless navigation has been successfully integrated in knee arthroplasty but its effectiveness in total hip arthroplasty (THA) has been debated. It has consistently been shown that navigation adds significant time and cost to the operation. Further, the relative success of traditional hip replacements has impeded the adoption of new techniques. Methods: We compared the operative time between fifty total hip replacements with and without the use of imageless navigation by a single senior surgeon in a retrospective study. We employed standard statistical tools to compare the two methods. A correlation-based analysis was used to delimit the "learned" phase of imageless navigation to make comparisons meaningful. Results: Contrary to what has previously been reported, there was no significant difference between operative time in navigated, when compared to traditional operations (p = 0.498). Only fourteen operations were required to delimit the learning phase of this operation. Discussion: This is the first study that demonstrates no added operative time when using imageless navigation in THA, achieved with an improved workflow. The results also demonstrate a very reasonable learning curve.
引用
收藏
页数:5
相关论文
共 18 条
[1]  
*ADD, 2016, XLSTAT 2016 DAT AN S
[2]   The effect of the orientation of the acetabular and femoral components on the range of motion of the hip at different head-neck ratios [J].
D'Lima, DD ;
Urquhart, AG ;
Buehler, KO ;
Walker, RH ;
Colwell, CW .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2000, 82A (03) :315-321
[3]   Effects of acetabular abduction on cup wear rates in total hip arthroplasty [J].
Del Schutte, H ;
Lipman, AJ ;
Bannar, SM ;
Livermore, JT ;
Ilstrup, D ;
Morrey, BF .
JOURNAL OF ARTHROPLASTY, 1998, 13 (06) :621-626
[4]  
DeWal Hargovind, 2003, Am J Orthop (Belle Mead NJ), V32, P377
[5]  
Donnelly W, 2016, COMBINED M ORTHOPAED
[6]   Computer navigation in total hip replacement: a meta-analysis [J].
Gandhi, Rajiv ;
Marchie, Anthony ;
Farrokhyar, Forough ;
Mahomed, Nizar .
INTERNATIONAL ORTHOPAEDICS, 2009, 33 (03) :593-597
[7]  
Hirakawa K, 2001, CLIN ORTHOP RELAT R, P135
[8]  
IBM Corporation, 2017, SPSS STAT WIND VERS
[9]   Imageless navigation for insertion of the acetabular component in total hip arthroplasty -: Is it as accurate as CT-based navigation? [J].
Kalteis, T ;
Handel, A ;
Bäthis, H ;
Perlick, L ;
Tingart, M ;
Grifka, J .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2006, 88B (02) :163-167
[10]   Greater accuracy in positioning of the acetabular cup by using an image-free navigation system [J].
Kalteis, T ;
Handel, M ;
Herold, T ;
Perlick, L ;
Baethis, H ;
Grifka, J .
INTERNATIONAL ORTHOPAEDICS, 2005, 29 (05) :272-276