RESPONSE FUNCTION MEASUREMENTS OF AN NE102A ORGANIC SCINTILLATOR USING AN AM-241-BE SOURCE

被引:16
作者
NAQVI, AA
AKSOY, A
KHIARI, FZ
COBAN, A
NAGADI, MM
ALOHALI, MA
ALJALAL, MA
机构
[1] Energy Research Laboratory, King Fahd University of Petroleum and Minerals, Dhahran
关键词
D O I
10.1016/0168-9002(94)90509-6
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The response function of a 125 mm diameter NE102A organic scintillation detector has been measured over the 2.7-14.8 MeV neutron energy range. The detector response function was derived from the light output for monoenergetic neutrons and gamma rays. The light output of the detector for monoenergetic neutrons was measured by selecting narrow gates in the time-of-flight (TOF) spectrum for a Am-241-Be neutron source. In order to provide check points on the data, the detector light output was also measured for monoenergetic neutrons from the D(d, n) and T(d, n) reactions. The response function of the NE102A detector is in good agreement (within 1-5%) with the published data of Cecil et al. [Nucl. Instr. and Meth. 161 (1979) 439].
引用
收藏
页码:514 / 519
页数:6
相关论文
共 8 条
[1]   RESPONSE-FUNCTION MEASUREMENT OF AN NE213 SCINTILLATOR USING THE H-2(D, N)HE-3 REACTION [J].
AKSOY, A ;
COBAN, A ;
NAQVI, AA ;
KHIARI, FZ ;
HANLY, JM ;
HOWELL, CR ;
TORNOW, W ;
FELSHER, PD ;
ALOHALI, MA ;
WALTER, RL .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 337 (2-3) :486-491
[2]   350-KEV ACCELERATOR FACILITY FOR THE UNIVERSITY-OF-PETROLEUM-AND-MINERALS [J].
ALJUWAIR, H ;
BLUME, G ;
JAARSMA, RJ ;
MEITZLER, CR ;
PURSER, KH .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1987, 24-5 :810-812
[3]   IMPROVED PREDICTIONS OF NEUTRON DETECTION EFFICIENCY FOR HYDROCARBON SCINTILLATORS FROM 1 MEV TO ABOUT 300 MEV [J].
CECIL, RA ;
ANDERSON, BD ;
MADEY, R .
NUCLEAR INSTRUMENTS & METHODS, 1979, 161 (03) :439-447
[4]  
FILCHENKOV VV, 1990, NUCL INSTRUM METH A, V291, P504
[5]   RELATIVE NEUTRON DETECTOR EFFICIENCY AND RESPONSE FUNCTION MEASUREMENTS WITH A CF-252 NEUTRON SOURCE [J].
GUL, K ;
NAQVI, AA ;
ALJUWAIR, HA .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1989, 278 (02) :470-476
[6]   ENERGY RESOLUTION TESTS OF 125 MM DIAMETER CYLINDRICAL NE213 DETECTOR USING MONOENERGETIC GAMMA-RAYS [J].
NAQVI, AA ;
ALJUWAIR, H ;
GUL, K .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1991, 306 (1-2) :267-271
[7]   ENERGY RESOLUTION OF NE102A AND NE230-SCINTILLATOR FOR MONOENERGETIC GAMMA-RAYS [J].
NAQVI, AA ;
KHIARI, FZ ;
COBAN, A ;
ALJALAL, AM .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1993, 324 (1-2) :223-225
[8]   LIGHT YIELD MEASUREMENTS OF A NE213-DETECTOR FOR 2.8-14.8 MEV NEUTRONS [J].
NAQVI, AA ;
KHIARI, FZ ;
AKSOY, A ;
COBAN, A ;
ALJALAL, MA .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1993, 325 (03) :574-577