MULTICENTER EVALUATION OF REFLOTRON(R) DIRECT DRY-CHEMISTRY ASSAY OF HIGH-DENSITY-LIPOPROTEIN CHOLESTEROL IN VENOUS AND FINGERSTICK SPECIMENS

被引:0
作者
WARNICK, GR
BOERMA, GJM
ASSMANN, G
ENDLER, AT
GERIQUE, G
GOTTO, AM
GRAZIANI, MS
LIPPI, U
PATSCH, W
RIESEN, WF
LEARY, ET
HILLER, G
ZERBACK, R
LEINBERGER, R
机构
[1] UNIV HOSP ROTTERDAM,DEPT CLIN CHEM,LIPID REFERENCE LAB,3015 GD ROTTERDAM,NETHERLANDS
[2] UNIV MUNSTER,INST KLIN CHEM & LAB MED,W-4400 MUNSTER,GERMANY
[3] STADT WIEN,KAISERIN ELISABETH SPITAL,A-1150 VIENNA,AUSTRIA
[4] UNIV AUTONOMA BARCELONA HOSP,SERV BIOQUIM,E-8025 BARCELONA,SPAIN
[5] BAYLOR COLL MED,CTR LIPID RES,HOUSTON,TX 77030
[6] OSPED MAGGIORE,CHIM CLIN LAB,I-37126 VERONA,ITALY
[7] KANTONS ST GALLEN,INST KLIN CHEM & HAMATOL,CH-9000 ST GALLEN,SWITZERLAND
[8] BOEHRINGER MANNHEIM GMBH,W-6800 MANNHEIM 31,GERMANY
关键词
REFLECTANCE PHOTOMETRY; ENZYMATIC METHODS; PHYSICIANS OFFICE TESTING;
D O I
暂无
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
The Reflotron(R) HDL Cholesterol test (Boehringer Mannheim GmbH) directly separates and analyzes high-density lipoprotein (HDL) cholesterol in plasma collected with EDTA in an integrated dry-reagent system suitable for alternative site testing of lipoproteins. We describe a multicenter evaluation of this test by two US and six European laboratories experienced in lipid analysis. Each laboratory compared the Reflotron with the same conventional wet-chemistry method, Boehringer phosphotungstate-Mg2+ precipitation with enzymatic cholesterol assay. Imprecision was within accepted guidelines, with CVs of less-than-or-equal-to 8% for fresh and frozen plasmas (median CV 1.7-3.9%) and for lyophilized sera (median CV 3.8-4.7%), similar to those of the conventional method. Results of linear-regression analysis were as follows: Reflotron HDL Cholesterol = 1.03 conventional - 3.9 mg/L, r = 0.987. The Reflotron results were somewhat low in the two US laboratories, demonstrating the need for general standardization of methods for measuring HDL cholesterol. Results from capillary fingerstick plasma agreed well with those from venous-derived plasma: capillary = 1.04 venous + 4.5 mg/L, r = 0.967. The system is relatively insensitive to interference from hemoglobin (less-than-or-equal-to 0.75 g/L), ascorbic acid (less-than-or-equal-to 0.3 g/L), bilirubin (less-than-or-equal-to 50 mg/L), cholesterol (less-than-or-equal-to 3.5 g/L), and triglycerides (less-than-or-equal-to 4 g/L). The relative ease of operation and the rapid availability of results (within 90 s for plasma collected in EDTA) make the method appropriate for use by well-trained, but not necessarily technical, operators in the physician's office or other alternative sites.
引用
收藏
页码:271 / 277
页数:7
相关论文
共 24 条
  • [1] ALBERS JJ, 1984, CLIN METABOLIC ASPEC, P381
  • [2] ASSMANN G, 1986, PROCAM TRIAL
  • [3] ASSMANN G, 1989, LIPID METABOLISM DIS
  • [4] SUR UN DOSAGE RAPIDE DU CHOLESTEROL LIE AUX ALPHA-LIPOPROTEINES ET AUX BETA-LIPOPROTEINES DU SERUM
    BURSTEIN, M
    SAMAILLE, J
    [J]. CLINICA CHIMICA ACTA, 1960, 5 (04) : 609 - 609
  • [5] BURSTEIN M, 1970, J LIPID RES, V11, P583
  • [7] HDL CHOLESTEROL AND OTHER LIPIDS IN CORONARY HEART-DISEASE - COOPERATIVE LIPOPROTEIN PHENOTYPING STUDY
    CASTELLI, WP
    DOYLE, JT
    GORDON, T
    HAMES, CG
    HJORTLAND, MC
    HULLEY, SB
    KAGAN, A
    ZUKEL, WJ
    [J]. CIRCULATION, 1977, 55 (05) : 767 - 772
  • [8] DEMACKER PNM, 1980, CLIN CHEM, V26, P1780
  • [9] GORDON DJ, 1989, HIGH DENSITY LIPOPRO, V2, P3
  • [10] HIGH-DENSITY LIPOPROTEIN AS A PROTECTIVE FACTOR AGAINST CORONARY HEART-DISEASE - FRAMINGHAM STUDY
    GORDON, T
    CASTELLI, WP
    HJORTLAND, MC
    KANNEL, WB
    DAWBER, TR
    [J]. AMERICAN JOURNAL OF MEDICINE, 1977, 62 (05) : 707 - 714