INVIVO MEASUREMENT OF BASILAR-MEMBRANE STIFFNESS

被引:66
作者
OLSON, ES
MOUNTAIN, DC
机构
[1] Department of Biomedical Engineering, Boston University, Boston
关键词
D O I
10.1121/1.400535
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Basilar membrane stiffness measurements were made in the base of the gerbil cochlea. Basilar membrane stiffness was determined by contacting the basilar membrane with a stainless steel needle (tip diameter 25-mu-m) attached to a force transducer, putting the needle/transducer structure through a low-frequency sinusoidal excursion with amplitude 5 or 25 nm, and measuring the restoring force exerted on the needle by the basilar membrane at the applied frequency. Stiffness was calculated as the amplitude of the restoring force divided by the amplitude of the excursion. Stiffness was measured over a 24-mu-m range of static displacements of the basilar membrane and is presented as stiffness versus static displacement. In cochleas that were not damaged during surgery the stiffness versus displacement characteristic usually had the following features: (1) an initial stiffness plateau with average stiffness 0.6 N/m; (2) a second plateau or level off with average stiffness 9.1 N/m; and (3) an increase in stiffness beyond the second plateau that was consistent with the theoretical stiffness-vs-displacement function of a beam. These features were present both pre- and post-mortem.
引用
收藏
页码:1262 / 1275
页数:14
相关论文
共 20 条
[1]   COCHLEAR PARTITION STIFFNESS - COMPOSITE BEAM MODEL [J].
ALLAIRE, P ;
RAYNOR, S ;
BILLONE, M .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1974, 55 (06) :1252-1258
[2]   MECHANICAL STIMULATION AND MICROMANIPULATION WITH PIEZOELECTRIC BIMORPH ELEMENTS [J].
COREY, DP ;
HUDSPETH, AJ .
JOURNAL OF NEUROSCIENCE METHODS, 1980, 3 (02) :183-202
[3]   INTRA-COCHLEAR SOUND PRESSURE MEASUREMENTS IN GUINEA-PIGS [J].
DANCER, A ;
FRANKE, R .
HEARING RESEARCH, 1980, 2 (3-4) :191-205
[4]   DIRECT MEASUREMENT OF BASILAR-MEMBRANE STIFFNESS IN THE GUINEA-PIG [J].
GUMMER, AW ;
JOHNSTONE, BM ;
ARMSTRONG, NJ .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1981, 70 (05) :1298-1309
[5]   COMPLIANCE OF THE HAIR BUNDLE ASSOCIATED WITH GATING OF MECHANOELECTRICAL TRANSDUCTION CHANNELS IN THE BULLFROGS SACCULAR HAIR CELL [J].
HOWARD, J ;
HUDSPETH, AJ .
NEURON, 1988, 1 (03) :189-199
[6]  
IURATO SALVATORE, 1962, JOUR ACOUSTICAL SOC AMER, V34, P1386, DOI 10.1121/1.1918355
[7]   RELATIONSHIP BETWEEN BASILAR-MEMBRANE TUNING AND HAIR CELL CONDITION [J].
KHANNA, SM ;
LEONARD, DGB .
HEARING RESEARCH, 1986, 23 (01) :55-70
[9]   STRUCTURAL IMPLICATIONS OF BASILAR-MEMBRANE COMPLIANCE MEASUREMENTS [J].
MILLER, CE .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1985, 77 (04) :1465-1474
[10]   WIDE-RANGE, LOW-OPERATING-VOLTAGE, BIMORPH STM - APPLICATION AS POTENTIOMETER [J].
MURALT, P ;
POHL, DW ;
DENK, W .
IBM JOURNAL OF RESEARCH AND DEVELOPMENT, 1986, 30 (05) :443-450