EFFECTS OF ANGIOGRAPHIC CONTRAST-MEDIA ON VENOUS ENDOTHELIUM OF RABBITS

被引:18
|
作者
THIESEN, B
MUTZEL, W
机构
[1] FREE UNIV BERLIN, INST VET PATHOL, W-1000 BERLIN 33, GERMANY
[2] SCHERING A6, RES LABS, BERLIN, GERMANY
关键词
Contrast media; Electron microscopy; Venous endothelium;
D O I
10.1097/00004424-199002000-00004
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The effects of ionic and nonionic contrast media on rabbit venous endothelium were examined. In anesthetized animals, caudal mesenteric veins were exposed and perfused with the ionic contrast medium, diatrizoate, and the nonionic contrast media iopromide and iotrolan for 2 minutes at 5 mL/minute. Control animals were similarly perfused with physiologic saline or a 23% sorbitol solution. The specimens were fixed in situ by perfusing 4% glutaraldehyde, and ultrathin stained sections were examined with an electron microscope. The hyperosmolar contrast medium diatrizoate produced shrinkage in cell cytoplasm and in nuclear material. There also were minor structural alterations in endoplasmic reticulum and widening of intercellular junctions. The nonionic contrast media iotrolan and iopromide caused mild to moderate changes in endothelial cells. Sorbitol infusion, however, affected venous endothelium more intensely than the ionic and nonionic contrast media, suggesting hyperosmolality as the causal factor in endothelial damage. © Lippincott-Raven Publishers.
引用
收藏
页码:121 / 126
页数:6
相关论文
共 50 条
  • [31] LACK OF INHIBITION OF THROMBIN GENERATION BY NONIONIC CONTRAST-MEDIA
    MAMON, JF
    FAREED, J
    HOPPENSTEADT, D
    MONCADA, R
    THROMBOSIS RESEARCH, 1991, 61 (02) : 165 - 170
  • [32] INADVERTENT INTRATHECAL USE OF IONIC CONTRAST-MEDIA FOR MYELOGRAPHY
    BOHN, HP
    REICH, L
    SULJAGAPETCHEL, K
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1992, 13 (06) : 1515 - 1519
  • [33] RENAL TOLERANCE OF CONTRAST-MEDIA IN DIABETIC-PATIENTS
    DERAY, G
    DUBOIS, M
    BAUMELOU, A
    JACOBS, C
    DIABETES & METABOLISM, 1991, 17 (03): : 379 - 382
  • [34] NEW DIRECTIONS IN THE DEVELOPMENT OF MR IMAGING CONTRAST-MEDIA
    BRASCH, RC
    RADIOLOGY, 1992, 183 (01) : 1 - 11
  • [35] USE OF INFORMED CONSENT FOR IONIC AND NONIONIC CONTRAST-MEDIA
    LAMBE, HA
    HOPPER, KD
    MATTHEWS, YL
    RADIOLOGY, 1992, 184 (01) : 145 - 148
  • [36] CHROMOSOME-DAMAGE FROM NONIONIC CONTRAST-MEDIA
    COCHRAN, ST
    NORMAN, A
    INVESTIGATIVE RADIOLOGY, 1994, 29 : S206 - S207
  • [37] IMMUNOLOGICAL BASIS FOR ADVERSE REACTIONS TO RADIOGRAPHIC CONTRAST-MEDIA
    STEJSKAL, V
    NILSSON, R
    GREPE, A
    ACTA RADIOLOGICA, 1990, 31 (06) : 605 - 612
  • [38] EFFECTS OF VASOCONSTRICTORS ON RABBIT CORONARY-ARTERIES EXPOSED TO ISOTONIC IONIC AND NONIONIC CONTRAST-MEDIA
    KARSTOFT, J
    BAATH, L
    JANSEN, I
    EDVINSSON, L
    INVESTIGATIVE RADIOLOGY, 1993, 28 (10) : 911 - 916
  • [39] Effect of contrast media formulation on computed tomography angiographic contrast enhancement
    Kishimoto, Miori
    Yamada, Kazutaka
    Tsuneda, Ryo
    Shimizu, Junichiro
    Iwasaki, Toshiroh
    Miyake, Yoh-Ichi
    VETERINARY RADIOLOGY & ULTRASOUND, 2008, 49 (03) : 233 - 237
  • [40] REPEATED INTRACORONARY INJECTIONS OF CONTRAST-MEDIA - ADDITIVE HEMODYNAMIC AND ELECTROPHYSIOLOGIC EFFECTS IN A DOG-MODEL
    JACOBSEN, EA
    KLOW, NE
    PEDERSEN, HK
    REFSUM, H
    INVESTIGATIVE RADIOLOGY, 1993, 28 (10) : 917 - 924