NONINVASIVE EVALUATION OF SYMPATHETIC NERVOUS-SYSTEM IN HUMAN HEART BY POSITRON EMISSION TOMOGRAPHY

被引:202
|
作者
SCHWAIGER, M
KALFF, V
ROSENSPIRE, K
HAKA, MS
MOLINA, E
HUTCHINS, GD
DEEB, M
WOLFE, E
WIELAND, DM
机构
[1] UNIV MICHIGAN,MED CTR,DIV NUCL MED,ANN ARBOR,MI 48109
[2] UNIV MICHIGAN,MED CTR,DEPT SURG,DIV CARDIOTHORAC SURG,ANN ARBOR,MI 48109
关键词
nervous system; sympathetic; positron emission tomography; [!sup]11[!/sup]C]hydroxyephedrine;
D O I
10.1161/01.CIR.82.2.457
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The noninvasive functional characterization of the cardiac sympathetic nervous system by imaging techniques may provide important pathophysiological information in various cardiac disease states. Hydroxyephedrine labeled with carbon 11 has been developed as a new catecholamine analogue to be used in the in vivo evaluation of presynaptic adrenergic nerve terminals by positron emission tomography (PET). To determine the feasibility of this imaging approach in the human heart, six normal volunteers and five patients with recent cardiac transplants underwent dynamic PET imaging after intravenous injection of 20 mCi [11C]hydroxyephedrine. Blood and myocardial tracer kinetics were assessed using a regions-of-interest approach. In normal volunteers, blood 11C activity cleared rapidly, whereas myocardium retained 11C activity with a long tissue half-life. Relative tracer retention in the myocardium averaged 79 ± 31% of peak activity at 60 minutes after tracer injection. The heart-to-blood 11C activity ratio exceeded 6:1 as soon as 30 minutes after tracer injection, yielding excellent image quality. Little regional variation of tracer retention was observed, indicating homogeneous sympathetic innervation throughout the left ventricle. In the transplant recipients, myocardial [11C]hydroxyephedrine retention at 60 minutes was significantly less (-82%) than that of normal volunteers, indicating only little non-neuronal binding of the tracer in the denervated human heart. Thus, [11C]hydroxyephedrine, in combination with dynamic PET imaging, allows the noninvasive delineation of myocardial adrenergic nerve terminals. Tracer kinetic modeling may permit quantitative assessment of myocardial catecholamine uptake, which will in turn provide insights into the effects of various disease processes on the neuronal integrity of the heart.
引用
收藏
页码:457 / 464
页数:8
相关论文
共 50 条
  • [1] Myocardial efficiency and sympathetic reinnervation after orthotopic heart transplantation - A noninvasive study with positron emission tomography
    Bengel, FM
    Ueberfuhr, P
    Schiepel, N
    Nekolla, SG
    Reichart, B
    Schwaiger, M
    CIRCULATION, 2001, 103 (14) : 1881 - 1886
  • [2] THE SYMPATHETIC NERVOUS-SYSTEM IS NOT INVOLVED IN THE DEVELOPMENT OF ATROPINE TACHYCARDIA
    SMIRNOV, VM
    BULLETIN OF EXPERIMENTAL BIOLOGY AND MEDICINE, 1994, 118 (09) : 929 - 932
  • [3] Sympathetic nervous system in heart failure
    Cohn, JN
    CIRCULATION, 2002, 106 (19) : 2417 - 2418
  • [4] Evaluation of a novel radiotracer for positron emission tomography imaging of reactive oxygen species in the central nervous system
    Wilson, Alan A.
    Sadovski, Oleg
    Nobrega, Jose N.
    Raymond, Roger J.
    Bambico, Francis R.
    Nashed, Mina G.
    Garcia, Armando
    Bloomfield, Peter M.
    Houle, Sylvain
    Mizrahi, Romina
    Tong, Junchao
    NUCLEAR MEDICINE AND BIOLOGY, 2017, 53 : 14 - 20
  • [5] Noninvasive quantification of rCBF using positron emission tomography
    Watabe, H
    Itoh, M
    Cunningham, V
    Lammertsma, AA
    Bloomfield, P
    Mejia, M
    Fujiwara, T
    Jones, AKP
    Jones, T
    Nakamura, T
    JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1996, 16 (02) : 311 - 319
  • [6] INTEGRATION OF POSITRON EMISSION TOMOGRAPHY IN NONINVASIVE CARDIOVASCULAR DIAGNOSTICS
    NITZSCHE, EU
    MULLER, P
    CZERNIN, J
    MOSER, E
    SCHELBERT, HR
    RADIOLOGE, 1992, 32 (06): : 266 - 275
  • [7] POSITRON EMISSION TOMOGRAPHY - A NEW TECHNIQUE FOR STUDIES OF THE CENTRAL-NERVOUS-SYSTEM
    ERIKSSON, L
    DAHLBOM, M
    WIDEN, L
    JOURNAL OF MICROSCOPY-OXFORD, 1990, 157 : 305 - 333
  • [8] NONINVASIVE QUANTIFICATION OF MYOCARDIAL PERFUSION USING POSITRON EMISSION TOMOGRAPHY
    BEANLANDS, R
    MUZIK, O
    HUTCHINS, G
    SCHWAIGER, M
    CORONARY ARTERY DISEASE, 1992, 3 (04) : 281 - 290
  • [9] Positron Emission Tomography in Coronary Heart Disease
    de Almeida, Jose
    Martinho, Sofia
    Goncalves, Lino
    Ferreira, Maria
    APPLIED SCIENCES-BASEL, 2022, 12 (09):
  • [10] MORPHOLOGY OF EXPERIMENTAL-TUMORS OF THE SYMPATHETIC NERVOUS-SYSTEM
    BENIASHVILI, DS
    EXPERIMENTAL PATHOLOGY, 1990, 39 (02): : 89 - 94