A Monte Carlo evaluation for effects of probable dimensional uncertainties of low dose rate brachytherapy seeds on dose

被引:5
作者
Camgoz, Berkay [1 ]
Kumru, Mehmet N. [1 ]
机构
[1] Ege Univ, Inst Nucl Sci, TR-35100 Izmir, Turkey
关键词
Brachytherapy; Dose; TG-43; report; Monte Carlo; EGSnrc;
D O I
10.1016/j.rpor.2014.01.001
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
The aim of this study is to determine effects of size deviations of brachytherapy seeds on two dimensional dose distributions around the seed. Although many uncertainties are well known, the uncertainties which stem from geometric features of radiation sources are weakly considered and predicted. Neither TG-43 report which is not completely in common consensus, nor individual scientific MC and experimental studies include sufficient data for geometric uncertainties. Sizes of seed and its components can vary in a manufacturing deviation. This causes geometrical uncertainties, too. In this study, three seeds which have different geometrical properties were modeled using EGSnrc-Code Packages. Seeds were designed with all their details using the geometry package. 5% deviations of seed sizes were assumed. Modified seeds were derived from original seed by changing sizes by 5%. Normalizations of doses which were calculated from three kinds of brachytherapy seed and their derivations were found to be about 3%-20%. It was shown that manufacturing differences of brachytherapy seed cause considerable changes in dose distribution. (C) 2014 Published by Elsevier Urban & Partner Sp. z o.o. on behalf of Greater Poland Cancer Centre.
引用
收藏
页码:301 / 309
页数:9
相关论文
共 16 条
[1]  
Becquerel H, 1901, CR HEBD ACAD SCI, V132, P1289
[2]   Differential dose contributions on total dose distribution of I-125 brachytherapy source [J].
Camgoz, B. ;
Yegin, G. ;
Kumru, M. N. .
REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2010, 15 (03) :69-74
[3]   A dosimetric uncertainty analysis for photon-emitting brachytherapy sources: Report of AAPM Task Group No. 138 and GEC-ESTRO [J].
DeWerd, Larry A. ;
Ibbott, Geoffrey S. ;
Meigooni, Ali S. ;
Mitch, Michael G. ;
Rivard, Mark J. ;
Stump, Kurt E. ;
Thomadsen, Bruce R. ;
Venselaar, Jack L. M. .
MEDICAL PHYSICS, 2011, 38 (02) :782-801
[4]   Accurate condensed history Monte Carlo simulation of electron transport. I. EGSnrc, the new EGS4 version [J].
Kawrakow, I .
MEDICAL PHYSICS, 2000, 27 (03) :485-498
[5]   An evaluation of the AAPM-TG43 dosimetry protocol for I-125 brachytherapy seed [J].
Mobit, P ;
Badragan, I .
PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (14) :3161-3170
[6]   DOSIMETRY OF INTERSTITIAL BRACHYTHERAPY SOURCES - RECOMMENDATIONS OF THE AAPM RADIATION-THERAPY COMMITTEE TASK GROUP NO 43 [J].
NATH, R ;
ANDERSON, LL ;
LUXTON, G ;
WEAVER, KA ;
WILLIAMSON, JF ;
MEIGOONI, AS .
MEDICAL PHYSICS, 1995, 22 (02) :209-234
[7]  
Nath R, 2002, APPL RADIAT ISOTOPES, V55, P813
[8]   Enhancements to commissioning techniques and quality assurance of brachytherapy treatment planning systems that use model-based dose calculation algorithms [J].
Rivard, Mark J. ;
Beaulieu, Luc ;
Mourtada, Firas .
MEDICAL PHYSICS, 2010, 37 (06) :2645-2658
[9]   Update of AAPM Task Group No. 43 Report: A revised AAPM protocol for brachytherapy dose calculations [J].
Rivard, MJ ;
Coursey, BM ;
DeWerd, LA ;
Hanson, WF ;
Huq, MS ;
Ibbott, GS ;
Mitch, MG ;
Nath, R ;
Williamson, JF .
MEDICAL PHYSICS, 2004, 31 (03) :633-674
[10]   A discretized approach to determining TG-43 brachytherapy dosimetry parameters:: case study using Monte Carlo calculations for the MED3633 103Pd source [J].
Rivard, MJ .
APPLIED RADIATION AND ISOTOPES, 2001, 55 (06) :775-782