CHARACTERIZATION OF POLYETHYLENE-GLYCOL MODIFIED PROTEINS USING CHARGE-REVERSED CAPILLARY ELECTROPHORESIS

被引:24
作者
CUNICO, RL
GRUHN, V
KRESIN, L
NITECKI, DE
WIKTOROWICZ, JE
机构
[1] CETUS CORP,1400 53RD ST,EMERYVILLE,CA 94608
[2] APPL BIOSYST INC,SAN JOSE,CA 95134
来源
JOURNAL OF CHROMATOGRAPHY | 1991年 / 559卷 / 1-2期
关键词
D O I
10.1016/0021-9673(91)80094-W
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A capillary electrophoretic method employing a charge reversal technique [J. E. Wiktorowicz and J. C. Colburn, Electrophoresis, 11 (1990) 769] has been developed to characterize polyethylene glycol (PEG)-proteins. A removable coating is applied to a standard fused-silica capillary in order to change the negative charge of the capillary surface to a positive charge. This prevents the adsorption of basic and PEG-proteins. The positive electrode is positioned at the detector end of the capillary, orienting electroosmotic flow towards the detector. Automated reconditioning procedures prior to each analysis give relative standard deviations in migration time and area of less than 2%, with most analysis times under 20 min. As the number of PEGs conjugated to a protein increases, the net positive charge and migration time of the copolymer decrease. Resulting peak widths are broad, reflecting the broad molecular mass distribution of PEGs and the heterogeneous nature of the PEG conjugates. This method can be used to monitor process steps, optimize reaction conditions, determine extent of modification, or assess product quality and consistency. Examples of PEG derivatized molecules characterized in our laboratory by charge-reversed capillary electrophoresis are tryptophan. Lys-Trp-Lys, lysozyme, myoglobin. RNase and immunoglobulin G; the size of the attached monomethoxy-PEG molecules varied from 0.15 kDa to 10 kDa (10(3) dalton).
引用
收藏
页码:467 / 477
页数:11
相关论文
共 21 条
  • [1] A WATER-SOLUBLE, MONITORABLE PEPTIDE AND PROTEIN CROSS-LINKING AGENT
    ALDWIN, L
    NITECKI, DE
    [J]. ANALYTICAL BIOCHEMISTRY, 1987, 164 (02) : 494 - 501
  • [2] USE OF ESTERS OF N-HYDROXYSUCCINIMIDE IN PEPTIDE SYNTHESIS
    ANDERSON, GW
    CALLAHAN, FM
    ZIMMERMAN, JE
    [J]. JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1964, 86 (09) : 1839 - +
  • [3] SPECTROSCOPIC CHARACTERIZATION OF POLYETHYLENEGLYCOL MODIFIED SUPEROXIDE-DISMUTASE - H-1-NMR STUDIES ON ITS CU2CO2 DERIVATIVE
    BANCI, L
    BERTINI, I
    CALICETI, P
    SCOLARO, LM
    SCHIAVON, O
    VERONESE, FM
    [J]. JOURNAL OF INORGANIC BIOCHEMISTRY, 1990, 39 (02) : 149 - 159
  • [4] FASMAN GD, 1986, HDB BIOTECHNOLOGY MO, V3
  • [5] PROTOCOL FOR RESOLVING PROTEIN MIXTURES IN CAPILLARY ZONE ELECTROPHORESIS
    GORDON, MJ
    LEE, KJ
    ARIAS, AA
    ZARE, RN
    [J]. ANALYTICAL CHEMISTRY, 1991, 63 (01) : 69 - 72
  • [6] APPLICATION OF FREE-SOLUTION CAPILLARY ELECTROPHORESIS TO THE ANALYTICAL SCALE SEPARATION OF PROTEINS AND PEPTIDES
    GROSSMAN, PD
    COLBURN, JC
    LAUER, HH
    NIELSEN, RG
    RIGGIN, RM
    SITTAMPALAM, GS
    RICKARD, EC
    [J]. ANALYTICAL CHEMISTRY, 1989, 61 (11) : 1186 - 1194
  • [7] HIGH-PERFORMANCE ELECTROPHORESIS - ELIMINATION OF ELECTROENDOSMOSIS AND SOLUTE ADSORPTION
    HJERTEN, S
    [J]. JOURNAL OF CHROMATOGRAPHY, 1985, 347 (02): : 191 - 198
  • [8] CARRIER-FREE ZONE ELECTROPHORESIS, DISPLACEMENT ELECTROPHORESIS AND ISOELECTRIC-FOCUSING IN A HIGH-PERFORMANCE ELECTROPHORESIS APPARATUS
    HJERTEN, S
    ELENBRING, K
    KILAR, F
    LIAO, JL
    CHEN, AJC
    SIEBERT, CJ
    ZHU, MD
    [J]. JOURNAL OF CHROMATOGRAPHY, 1987, 403 : 47 - 61
  • [9] JACKSON CC, 1986, ANAL BIOCHEM, V165, P114
  • [10] CAPILLARY ZONE ELECTROPHORESIS
    JORGENSON, JW
    LUKACS, KD
    [J]. SCIENCE, 1983, 222 (4621) : 266 - 272