MICROBIOLOGICAL STUDIES OF LAMINAR AIR FLOW UNIT FOR PATIENTS

被引:19
作者
BODEY, GP
GEWERTZ, B
机构
[1] University of Texas M. D. Anderson Hospital and Tumor Institute, Houston, 77025
来源
ARCHIVES OF ENVIRONMENTAL HEALTH | 1969年 / 19卷 / 06期
基金
美国国家卫生研究院;
关键词
D O I
10.1080/00039896.1969.10666933
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A laminar air flow (LAF) unit consisting of two patient rooms has been installed for patients’ undergoing cancer chemotherapy. Air circulated through the room in a horizontal laminar flow pattern after passing a bank of high efficiency filters. All necessary patient facilities were provided in the room. The rooms were cleaned with an organic tin compound prior to patient occupancy which reduced microbial contamination by 102 organisms. The concentration of organisms in air samples was 103 less in the LAF rooms than in regular hospital rooms. Nearly 80% of samples from floor sites, 86% from wall sites, and 88% from furnishings were sterile during patient occupancy. © 1969 Taylor & Francis Group, LLC.
引用
收藏
页码:798 / &
相关论文
共 12 条
[1]  
BEAKLEY JW, 1966, SCRR66385 SAND CORP
[2]  
BODEY GP, 1968, CANCER-AM CANCER SOC, V22, P1018, DOI 10.1002/1097-0142(196811)22:5<1018::AID-CNCR2820220518>3.0.CO
[3]  
2-0
[4]  
BODEY GP, TO BE PUBLISHED
[5]   MEDICAL APPLICATIONS OF DUST-FREE ROOMS .2. ELIMINATION OF AIRBORNE BACTERIA FROM AN OPERATING THEATER [J].
CORIELL, LL ;
BLAKEMORE, WS ;
MCGARRITY, GJ .
JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1968, 203 (12) :1038-+
[6]  
EDWARDS PR, 1964, IDENTIFICATION ENTER
[7]  
FINCHER EL, 1966, CONTROL INFECTIONS H, P200
[8]   MICROBIOLOGICAL STUDIES CONDUCTED IN A VERTICAL LAMINAR AIRFLOW SURGERY [J].
MCDADE, JJ ;
WHITCOMB, JG ;
RYPKA, EW ;
WHITFIELD, WJ ;
FRANKLIN, CM .
JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1968, 203 (02) :125-+
[9]  
Michaelsen G S, 1967, Hospitals, V41, P91
[10]  
WHITFIELD WJ, 1962, SCDC662277 SAND CORP