THE ACCURACY OF CT ANGIOGRAPHY FOR THE DEMONSTRATION OF RENAL-ARTERY STENOSIS

被引:41
作者
GALANSKI, M [1 ]
PROKOP, M [1 ]
CHAVAN, A [1 ]
SCHAEFER, C [1 ]
JANDELEIT, K [1 ]
OLBRICHT, C [1 ]
机构
[1] HANNOVER MED SCH,NEPHROL ABT,D-30625 HANNOVER,GERMANY
来源
FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN | 1994年 / 161卷 / 06期
关键词
CT ANGIOGRAPHY; SPIRAL CT; RENAL ARTERY STENOSIS; RENOVASCULAR HYPERTENSION;
D O I
10.1055/s-2008-1032579
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Spiral CT in the form of CT angiography (CTA) provides a new method for the investigation of the large vessels. 52 patients with suspected renovascular hypertension were examined by CTA and arterial DSA. The computer tomographic and angiographic findings in 124 renal arteries were compared. Sensitivity of CTA for demonstrating renal artery stenosis was 95%, and for relevant stenoses it actually reached 100%. Specificity was 92%. Positive/negative prediction value was 85% and 100%. CTA proved outstandingly good for demonstrating or excluding renal artery stenosis and was superior to other imaging methods in several respects. CTA requires high contrast values, optimal timing and careful evaluation. Amongst various forms of image reconstruction, interactive viewing of the primary axial images and multiplanar reconstruction in a cine mode are essential and MIP projections are valuable.
引用
收藏
页码:519 / 525
页数:7
相关论文
共 50 条
  • [31] MALIGNANT HYPERTENSION AND RENAL-FAILURE - SCLERODERMA RENAL CRISIS OR RENAL-ARTERY STENOSIS
    MORRIS, K
    CONNOLLY, JO
    DONNELL, PJ
    SCOBLE, JE
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 1994, 9 (10) : 1489 - 1491
  • [32] Accuracy of colour duplex sonography for the diagnosis of renal artery stenosis
    Saeed, Aso
    Bergstrom, Goran
    Zachrisson, Karin
    Guron, Gregor
    Nowakowska-Fortuna, Elzbieta
    Fredriksen, Ellen
    Lonn, Lars
    Jensen, Gert
    Herlitz, Hans
    JOURNAL OF HYPERTENSION, 2009, 27 (08) : 1690 - 1696
  • [33] The utility of spiral computed tomography angiography in the diagnosis of renal artery stenosis
    Juszkat, Robert
    Radziemski, Artur
    Posadzy-Malaczynska, Anna
    Nowak, Violetta
    Sosnowski, Piotr
    Tykarski, Andrzej
    ARTERIAL HYPERTENSION, 2006, 10 (06): : 518 - 523
  • [34] Diagnosis of renal artery stenosis by spiral computed tomography angiography (CTA)
    Spitthöver, R
    Stoeblen, F
    Neumann, K
    Henseke, P
    Philipp, T
    Müller, RD
    NIEREN-UND HOCHDRUCKKRANKHEITEN, 2000, 29 (06) : 245 - 252
  • [35] PTA OF RENAL-ARTERY STENOSIS - THERAPY OF ARTERIAL-HYPERTENSION AND KIDNEY-PRESERVATION
    HIRNING, T
    GERLACH, A
    ARLART, IP
    NIEREN-UND HOCHDRUCKKRANKHEITEN, 1991, 20 (10) : 556 - 558
  • [36] Leukoaraiosis and Carotid Artery Stenosis: Evaluation With CT Angiography
    Demirtas, Hakan
    Ozkaynak, Can
    Durmaz, Mehmet Sedat
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2013, 37 (03) : 327 - 332
  • [37] Multidetector spiral CT renal angiography in the diagnosis of renal artery fibromuscular dysplasia
    Sabharwal, Rohan
    Vladica, Philip
    Coleman, Patrick
    EUROPEAN JOURNAL OF RADIOLOGY, 2007, 61 (03) : 520 - 527
  • [38] CASE-REPORT - THE ROLE OF ANGIOPLASTY AND RENAL-ARTERY STENTING FOR BILATERAL RENAL-ARTERY STENOSIS PRIOR TO AORTIC-ANEURYSM REPAIR
    THOMAS, SM
    BELLI, AM
    MINIMALLY INVASIVE THERAPY, 1995, 4 (02): : 105 - 107
  • [39] IMPLANTATION OF A BALLON-EXPANDABLE VASCULAR PROSTHESIS IN RENAL-ARTERY STENOSIS
    HUPPERT, PE
    DUDA, SH
    MICHEL, J
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1991, 154 (01): : 117 - 119
  • [40] HYPERTENSION IN NEUROFIBROMATOSIS WITH RECURRENT RENAL-ARTERY STENOSIS AND INFRARENOL COARCTATION OF THE AORTA
    ZWAAN, M
    HEIDBUCHEL, K
    MARIENHOFF, N
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1991, 154 (01): : 115 - 116