THE ACCURACY OF CT ANGIOGRAPHY FOR THE DEMONSTRATION OF RENAL-ARTERY STENOSIS

被引:41
|
作者
GALANSKI, M [1 ]
PROKOP, M [1 ]
CHAVAN, A [1 ]
SCHAEFER, C [1 ]
JANDELEIT, K [1 ]
OLBRICHT, C [1 ]
机构
[1] HANNOVER MED SCH,NEPHROL ABT,D-30625 HANNOVER,GERMANY
来源
FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN | 1994年 / 161卷 / 06期
关键词
CT ANGIOGRAPHY; SPIRAL CT; RENAL ARTERY STENOSIS; RENOVASCULAR HYPERTENSION;
D O I
10.1055/s-2008-1032579
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Spiral CT in the form of CT angiography (CTA) provides a new method for the investigation of the large vessels. 52 patients with suspected renovascular hypertension were examined by CTA and arterial DSA. The computer tomographic and angiographic findings in 124 renal arteries were compared. Sensitivity of CTA for demonstrating renal artery stenosis was 95%, and for relevant stenoses it actually reached 100%. Specificity was 92%. Positive/negative prediction value was 85% and 100%. CTA proved outstandingly good for demonstrating or excluding renal artery stenosis and was superior to other imaging methods in several respects. CTA requires high contrast values, optimal timing and careful evaluation. Amongst various forms of image reconstruction, interactive viewing of the primary axial images and multiplanar reconstruction in a cine mode are essential and MIP projections are valuable.
引用
收藏
页码:519 / 525
页数:7
相关论文
共 50 条
  • [1] ACCURACY OF ECHO-DOPPLER FLOWMETRY FOR RENAL-ARTERY STENOSIS
    ANTONICA, G
    SABBA, C
    BERARDI, E
    BUONAMICO, P
    PAOLO, C
    VULPIS, V
    ETTORRE, G
    PIRRELLI, A
    ALBANO, O
    JOURNAL OF HYPERTENSION, 1991, 9 : S240 - S241
  • [2] MAGNETIC-RESONANCE ANGIOGRAPHY OF RENAL-ARTERY STENOSIS
    GRIST, TM
    AMERICAN JOURNAL OF KIDNEY DISEASES, 1994, 24 (04) : 700 - 712
  • [3] MAGNETIC-RESONANCE ANGIOGRAPHY IN THE DIAGNOSIS OF RENAL-ARTERY STENOSIS
    POSTMA, CT
    HARTOG, O
    ROSENBUSCH, G
    THIEN, T
    JOURNAL OF HYPERTENSION, 1993, 11 : S204 - S205
  • [4] Helical CT angiography of renal artery stenosis - Reply
    Beregi, JP
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1997, 168 (05) : 1380 - 1381
  • [5] NATURAL-HISTORY OF RENAL-ARTERY STENOSIS
    BERGENTZ, SE
    ANNALES CHIRURGIAE ET GYNAECOLOGIAE, 1992, 81 (02) : 98 - 101
  • [6] Diagnostic sensitivity and specificity of CT angiography for renal artery stenosis in children
    Orman, Gunes
    Masand, Prakash M.
    Kukreja, Kamlesh U.
    Acosta, Alisa A.
    Guillerman, R. Paul
    Jadhav, Siddharth P.
    PEDIATRIC RADIOLOGY, 2021, 51 (03) : 419 - 426
  • [7] Diagnostic sensitivity and specificity of CT angiography for renal artery stenosis in children
    Gunes Orman
    Prakash M. Masand
    Kamlesh U. Kukreja
    Alisa A. Acosta
    R. Paul Guillerman
    Siddharth P. Jadhav
    Pediatric Radiology, 2021, 51 : 419 - 426
  • [9] Dependence of Renal Blood Flow on Renal Artery Stenosis Measured Using CT Angiography
    Luedemann, L.
    Nafz, B.
    Elsner, F.
    Grosse-Siestrup, C.
    Meissler, M.
    Persson, P.
    Gutberlet, M.
    Lengsfeld, P.
    Voth, M.
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2011, 183 (03): : 267 - 273
  • [10] RENAL-ARTERY STENOSIS ASSOCIATED WITH MELORHEOSTOSIS
    IGLESIAS, JH
    STOCKS, AL
    PENA, DR
    NEIBERGER, RE
    PEDIATRIC NEPHROLOGY, 1994, 8 (04) : 441 - 443