REPAIR OF OSTEOCHONDRAL DEFECTS IN THE RABBIT KNEE WITH GORE-TEX(TM) (EXPANDED POLYTETRAFLUOROETHYLENE) - AN EXPERIMENTAL-STUDY

被引:21
|
作者
HANFF, G
SOLLERMAN, C
ABRAHAMSSON, SO
LUNDBORG, G
机构
[1] SAHLGRENS UNIV HOSP, DEPT HAND SURG, S-41345 GOTHENBURG, SWEDEN
[2] MALMO GEN HOSP, DEPT HAND SURG, S-21401 MALMO, SWEDEN
关键词
Cartilage repair; Cell ingrowth; E-PTFE; Knee joint; Osteochondral defect;
D O I
10.3109/02844319009041282
中图分类号
R61 [外科手术学];
学科分类号
摘要
In 28 knee joints in 14 rabbits 4 mm circular osteochondral defects were created in each medial femoral condyle. In 24 of the knee joints 4 mm Gore-TexTM (E-PTFE) patches were glued into the defects with fibrin glue. Four joints were left without implants and served as controls. In 16 joints the membrane showed good macroscopic incorporation into the joint surface. In four joints the E-PTFE patches were lying loose. In the controls the defects were covered by thin irregular layers of reparative tissue. On histological examination at 12 weeks, cells were seen proliferating through the membrane and overlying its joint facing surface with the morphological appearance of the outer layers of the normal articular surface. We conclude that Gore-TexTM might be of potential value in restoring the architecture of a damaged articular surface. © 1990 Informa UK Ltd All rights reserved: reproduction in whole or part not permitted.
引用
收藏
页码:217 / 223
页数:7
相关论文
共 50 条
  • [21] GLUTARALDEHYDE TANNED OVINE COLLAGEN COMPARED WITH POLYTETRAFLUOROETHYLENE (GORE-TEX) AS A CONDUIT FOR SMALL CALIBER ARTERY SUBSTITUTION - AN EXPERIMENTAL-STUDY IN DOGS
    KETHARANATHAN, V
    CHRISTIE, BA
    AUSTRALIAN AND NEW ZEALAND JOURNAL OF SURGERY, 1981, 51 (06): : 556 - 561
  • [22] ALLOPLASTIC REPLACEMENT OF CANINE URETER BY EXPANDED POLYTETRAFLUOROETHYLENE (GORE-TEX) GRAFTS - PRELIMINARY-REPORT
    DREIKORN, K
    LOBELENZ, J
    HORSCH, R
    ROHL, L
    EUROPEAN UROLOGY, 1978, 4 (05) : 379 - 381
  • [23] CLOSURE OF THE PERICARDIUM USING EXPANDED POLYTETRAFLUOROETHYLENE GORE-TEX SURGICAL MEMBRANE - CLINICAL-EXPERIENCE
    MINALE, C
    HOLLWEG, G
    NIKOL, S
    MITTERMAYER, C
    MESSMER, BJ
    THORACIC AND CARDIOVASCULAR SURGEON, 1987, 35 (05): : 312 - 315
  • [24] Repair of bile duct injuries with gore-tex vascular grafts: Experimental study in dogs
    Néstor A. Gómez
    Ludwig R. Alvarez
    Alfredo Mite
    Jean P. Andrade
    José R. Alvarez
    Paola E. Vargas
    Nancy E. Tomalá
    Alex F. Vivas
    Jorge A. Zapatier
    Journal of Gastrointestinal Surgery, 2002, 6 : 116 - 120
  • [25] REPAIR OF ABDOMINAL-WALL DEFECTS - GORE-TEX VS MARLEX GRAFT
    SHER, W
    POLLACK, D
    PAULIDES, CA
    MATSUMOTO, T
    AMERICAN SURGEON, 1980, 46 (11) : 618 - 623
  • [26] Repair of bile duct injuries with Gore-Tex vascular grafts:: Experimental study in dogs
    Gómez, NA
    Alvarez, LR
    Mite, A
    Andrade, JP
    Alvarez, JR
    Vargas, PE
    Tomalá, NE
    Vivas, AF
    Zapatier, JA
    JOURNAL OF GASTROINTESTINAL SURGERY, 2002, 6 (01) : 116 - 120
  • [27] COMPARISON OF MARLEX AND GORE-TEX TO REPAIR ABDOMINAL-WALL DEFECTS IN THE RAT
    MURPHY, JL
    FREEMAN, JB
    DIONNE, PG
    CANADIAN JOURNAL OF SURGERY, 1989, 32 (04) : 244 - &
  • [28] POSTOPERATIVE ANGIOGRAPHIC ASSESSMENT OF MODIFIED BLALOCK-TAUSSIG SHUNTS USING EXPANDED POLYTETRAFLUOROETHYLENE (GORE-TEX)
    MCKAY, R
    LEVAL, MRD
    REES, P
    TAYLOR, JFN
    MACARTNEY, FJ
    STARK, J
    ANNALS OF THORACIC SURGERY, 1980, 30 (02): : 137 - 145
  • [29] Anti-adhesive properties of polytetrafluoroethylene (Gore-Tex®) in middle ear surgery.: An experimental study
    Vicente, J
    Ramírez-Camacho, R
    Trinidad, A
    García-Berrocal, JR
    Lobo, D
    Pinilla, M
    ACTA OTO-LARYNGOLOGICA, 2006, 126 (02) : 144 - 148
  • [30] Fifteen years of experience with frontalis suspension using polytetrafluoroethylene (Gore-Tex®) suture in blepharoptosis repair
    Luiz Leonardo, Fabio Henrique
    Pieroni Goncalves, Allan C.
    ARQUIVOS BRASILEIROS DE OFTALMOLOGIA, 2020, 83 (01) : 39 - 42