COMPUTERIZED VOLUME MEASUREMENT OF BRAIN STRUCTURE

被引:67
作者
ASHTARI, M
ZITO, JL
GOLD, BI
LIEBERMAN, JA
BORENSTEIN, MT
HERMAN, PG
机构
[1] SUNY STONY BROOK,LAKEVILLE IMAGING CTR,STONY BROOK,NY 11794
[2] LONG ISL JEWISH MED CTR,DEPT PSYCHIAT,NEW HYDE PK,NY 11042
[3] EKTRON,APPL IMAGING,BEDFORD,MA
关键词
3-D gradient echo; Computer mensuration; Magnetic resonance imaging; Ventricular system; Volume measurement;
D O I
10.1097/00004424-199007000-00009
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Morphometric analysis of brain structures recently has become a main focus of interest in studies of some neuropsychiatric diseases. Limitations in imaging and mensuration methodology that is available currently for quantitative measurement of anatomic structures have prompted the development of a computerized system to study brain morphometry. A menudriven semi-automated computer system has been developed to assess in vivo brain morphometry using three-dimensional (3-D) magnetic resonance (MR), gradient echo, contiguous images of the whole brain. Accuracy of the system was tested with phantoms creating white on black contrast to simulate the brain tissue surrounded by subarachnoid cerebrospinal fluid (CSF), and a second set of phantoms creating black on white contrast to simulate the ventricular system in the brain tissue. The first set of phantoms was composed of three waterfilled balloons (spherical, elliptical, and multiform) and a fresh postmortem brain. The second set of phantoms consisted of three rods of different diameters from a simple geometric plexiglass rod phantom and a life size cast of a human ventricular phantom. System accuracy was generally within 2.0% of the true volumes. System reliability was evaluated in three patient populations; 12 patients with Alzheimer’s disease, nine with schizophrenia and nine healthy controls agematched to the patients with Alzheimer’s disease. Two independent observers measured the ventricular systems of these patients. Reliability of the system was addressed by the correlation between the two sets of measurements. For the sample as a whole, and each of the subgroups, the correlation between the two observers was 0.99. This system compares favorably with other morphometric methods reported. © Lippincott-Raven Publishers.
引用
收藏
页码:798 / 805
页数:8
相关论文
共 50 条
[41]   The spine-brain axis: is spinal anatomy associated with brain volume? [J].
Grosu, Sergio ;
Nikolova, Trayana ;
Lorbeer, Roberto ;
Stoecklein, Veit M. ;
Rospleszcz, Susanne ;
Fink, Nicola ;
Schlett, Christopher L. ;
Storz, Corinna ;
Beller, Ebba ;
Keeser, Daniel ;
Heier, Margit ;
Kiefer, Lena S. ;
Maurer, Elke ;
Walter, Sven S. ;
Ertl-Wagner, Birgit B. ;
Ricke, Jens ;
Bamberg, Fabian ;
Peters, Annette ;
Stoecklein, Sophia .
BRAIN COMMUNICATIONS, 2024, 6 (05)
[42]   Rapid volume measurement for large bulk cargo [J].
Yang D.-S. ;
Dong L.-L. ;
Liang Q.-Q. ;
Xu W.-H. .
Guangxue Jingmi Gongcheng/Optics and Precision Engineering, 2016, 24 (09) :2126-2133
[43]   Precision in situ volume measurement of micro droplets [J].
Fan, Kuang-Chao ;
Chen, Jhih-Yuan ;
Wang, Ching-Hua ;
Pan, Wen-Chueh .
JOURNAL OF OPTICS A-PURE AND APPLIED OPTICS, 2009, 11 (01)
[44]   Right ventricular volume measurement by conductance catheter [J].
Danton, MHD ;
Greil, GF ;
Byrne, JG ;
Hsin, M ;
Cohn, L ;
Maier, SE .
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2003, 285 (04) :H1774-H1785
[45]   Uterine fibroid segmentation and volume measurement on MRI [J].
Yao, Jianhua ;
Chen, David ;
Lu, Wenzhu ;
Premkumar, Ahalya .
MEDICAL IMAGING 2006: PHYSIOLOGY, FUNCTION, AND STRUCTURE FROM MEDICAL IMAGES PTS 1 AND 2, 2006, 6143
[46]   Measurement of Cavity Volume Based on Machine Vision [J].
Hao, Jian-Jun ;
Liu, Zi-Tao ;
Jiang, Qiang ;
Liang, Xiao-Long .
ADVANCED MEASUREMENT AND TEST, PTS 1-3, 2011, 301-303 :1196-1201
[47]   Optical Measurement Of Polyhedral Volume Based On DSP [J].
Zhou, Jinrong ;
Huang, Wenming ;
Zheng, Nan .
PROCEEDINGS OF THE 2017 2ND JOINT INTERNATIONAL INFORMATION TECHNOLOGY, MECHANICAL AND ELECTRONIC ENGINEERING CONFERENCE (JIMEC 2017), 2017, 62 :450-453
[48]   Methodology of Volume Measurement by Depth Imaging Technology [J].
Sun, Yunqi ;
Zhao, Yuxin ;
Jin, Yuanhao ;
Li, Qunqing ;
Zhang, Suyi ;
Liu, Miao ;
Lin, Feng ;
Huang, Mengyang .
2021 IEEE INTERNATIONAL CONFERENCE ON IMAGING SYSTEMS AND TECHNIQUES (IST), 2021,
[49]   Measurement of the cervical spinal cord volume on MRI [J].
Yanase, Makoto ;
Matsuyama, Yukihiro ;
Hirose, Kazuyoshi ;
Takagi, Hideki ;
Yamada, Masami ;
Iwata, Hisashi ;
Ishiguro, Naoki .
JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2006, 19 (02) :125-129
[50]   Measuring variability of local brain volume using improved volume preserved warping [J].
Li, Xuzhou ;
Huang, Manli ;
Hao, Xuejun ;
Zhao, Zhiyong ;
Xu, Dongrong .
COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2022, 96