COMPUTERIZED VOLUME MEASUREMENT OF BRAIN STRUCTURE

被引:67
作者
ASHTARI, M
ZITO, JL
GOLD, BI
LIEBERMAN, JA
BORENSTEIN, MT
HERMAN, PG
机构
[1] SUNY STONY BROOK,LAKEVILLE IMAGING CTR,STONY BROOK,NY 11794
[2] LONG ISL JEWISH MED CTR,DEPT PSYCHIAT,NEW HYDE PK,NY 11042
[3] EKTRON,APPL IMAGING,BEDFORD,MA
关键词
3-D gradient echo; Computer mensuration; Magnetic resonance imaging; Ventricular system; Volume measurement;
D O I
10.1097/00004424-199007000-00009
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Morphometric analysis of brain structures recently has become a main focus of interest in studies of some neuropsychiatric diseases. Limitations in imaging and mensuration methodology that is available currently for quantitative measurement of anatomic structures have prompted the development of a computerized system to study brain morphometry. A menudriven semi-automated computer system has been developed to assess in vivo brain morphometry using three-dimensional (3-D) magnetic resonance (MR), gradient echo, contiguous images of the whole brain. Accuracy of the system was tested with phantoms creating white on black contrast to simulate the brain tissue surrounded by subarachnoid cerebrospinal fluid (CSF), and a second set of phantoms creating black on white contrast to simulate the ventricular system in the brain tissue. The first set of phantoms was composed of three waterfilled balloons (spherical, elliptical, and multiform) and a fresh postmortem brain. The second set of phantoms consisted of three rods of different diameters from a simple geometric plexiglass rod phantom and a life size cast of a human ventricular phantom. System accuracy was generally within 2.0% of the true volumes. System reliability was evaluated in three patient populations; 12 patients with Alzheimer’s disease, nine with schizophrenia and nine healthy controls agematched to the patients with Alzheimer’s disease. Two independent observers measured the ventricular systems of these patients. Reliability of the system was addressed by the correlation between the two sets of measurements. For the sample as a whole, and each of the subgroups, the correlation between the two observers was 0.99. This system compares favorably with other morphometric methods reported. © Lippincott-Raven Publishers.
引用
收藏
页码:798 / 805
页数:8
相关论文
共 50 条
  • [21] Improved volumetric measurement of brain structure with a distortion correction procedure using an ADNI phantom
    Maikusa, Norihide
    Yamashita, Fumio
    Tanaka, Kenichiro
    Abe, Osamu
    Kawaguchi, Atsushi
    Kabasawa, Hiroyuki
    Chiba, Shoma
    Kasahara, Akihiro
    Kobayashi, Nobuhisa
    Yuasa, Tetsuya
    Sato, Noriko
    Matsuda, Hiroshi
    Iwatsubo, Takeshi
    MEDICAL PHYSICS, 2013, 40 (06)
  • [22] Establishment of novel technical methods for evaluating brain edema and lesion volume in stroked rats: A standardization of measurement procedures
    Boyko, Matthew
    Zvenigorodsky, Vladislav
    Grinshpun, Julia
    Shiyntum, Honore N.
    Melamed, Israel
    Kutz, Ruslan
    Shelef, Ilan
    Brotfain, Evgeni
    Frank, Dmitry
    Zlotnik, Alexander
    BRAIN RESEARCH, 2019, 1718 : 12 - 21
  • [23] Training and calibration improve inter-reader reliability of joint damage assessment using magnetic resonance image scoring and computerized erosion volume measurement
    Bird, P
    Joshua, F
    Lassere, M
    Shnier, R
    Edmonds, J
    JOURNAL OF RHEUMATOLOGY, 2005, 32 (08) : 1452 - 1458
  • [24] SPECIFICATION AND SELECTION OF REGIONS OF INTEREST (ROIS) IN A COMPUTERIZED BRAIN ATLAS
    BOHM, C
    GREITZ, T
    SEITZ, R
    ERIKSSON, L
    JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1991, 11 (02) : A64 - A68
  • [25] Computerized Brain Database Management System for Radiological Department in Hospital
    Sim, K. S.
    Kho, T. K.
    Abas, F. S.
    Ting, F. F.
    Teh, V.
    Ee, C. S.
    PROCEEDINGS OF 2016 INTERNATIONAL CONFERENCE ON ROBOTICS, AUTOMATION AND SCIENCES (ICORAS 2016), 2016,
  • [26] A COMPUTERIZED BRAIN ATLAS - CONSTRUCTION, ANATOMICAL CONTENT, AND SOME APPLICATIONS
    GREITZ, T
    BOHM, C
    HOLTE, S
    ERIKSSON, L
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1991, 15 (01) : 26 - 38
  • [27] High precision measurement of cartridge volume
    Guo, Hao
    Feng, Jin-Liang
    Zhang, Yao-Yu
    Cai, Cun-Liang
    Li, Si-Qi
    Binggong Xuebao/Acta Armamentarii, 2015, 36 (04): : 758 - 762
  • [28] Optical System for Drop Volume Measurement
    Norgia, Michele
    Magnani, Alessandro
    Melchionni, Dario
    Pesatori, Alessandro
    2014 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE (I2MTC) PROCEEDINGS, 2014, : 1322 - 1325
  • [29] Capacitive measurement of infusion fluid volume
    Dziadak, Bogdan
    Graffstein, Piotr
    PRZEGLAD ELEKTROTECHNICZNY, 2024, 100 (05): : 258 - 262
  • [30] Influence of Bubbles in Diesel Volume Measurement
    Guoyu Chen
    Tiange Xiao
    Yong Wan
    Houlin Hu
    Huanhuan Lin
    Liling Chen
    Guixiong Liu
    Yanhua Peng
    Chemistry and Technology of Fuels and Oils, 2022, 57 : 1005 - 1012