COMPUTERIZED VOLUME MEASUREMENT OF BRAIN STRUCTURE

被引:67
作者
ASHTARI, M
ZITO, JL
GOLD, BI
LIEBERMAN, JA
BORENSTEIN, MT
HERMAN, PG
机构
[1] SUNY STONY BROOK,LAKEVILLE IMAGING CTR,STONY BROOK,NY 11794
[2] LONG ISL JEWISH MED CTR,DEPT PSYCHIAT,NEW HYDE PK,NY 11042
[3] EKTRON,APPL IMAGING,BEDFORD,MA
关键词
3-D gradient echo; Computer mensuration; Magnetic resonance imaging; Ventricular system; Volume measurement;
D O I
10.1097/00004424-199007000-00009
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Morphometric analysis of brain structures recently has become a main focus of interest in studies of some neuropsychiatric diseases. Limitations in imaging and mensuration methodology that is available currently for quantitative measurement of anatomic structures have prompted the development of a computerized system to study brain morphometry. A menudriven semi-automated computer system has been developed to assess in vivo brain morphometry using three-dimensional (3-D) magnetic resonance (MR), gradient echo, contiguous images of the whole brain. Accuracy of the system was tested with phantoms creating white on black contrast to simulate the brain tissue surrounded by subarachnoid cerebrospinal fluid (CSF), and a second set of phantoms creating black on white contrast to simulate the ventricular system in the brain tissue. The first set of phantoms was composed of three waterfilled balloons (spherical, elliptical, and multiform) and a fresh postmortem brain. The second set of phantoms consisted of three rods of different diameters from a simple geometric plexiglass rod phantom and a life size cast of a human ventricular phantom. System accuracy was generally within 2.0% of the true volumes. System reliability was evaluated in three patient populations; 12 patients with Alzheimer’s disease, nine with schizophrenia and nine healthy controls agematched to the patients with Alzheimer’s disease. Two independent observers measured the ventricular systems of these patients. Reliability of the system was addressed by the correlation between the two sets of measurements. For the sample as a whole, and each of the subgroups, the correlation between the two observers was 0.99. This system compares favorably with other morphometric methods reported. © Lippincott-Raven Publishers.
引用
收藏
页码:798 / 805
页数:8
相关论文
共 50 条
  • [1] Reproducibility of intracranial volume measurement by unsupervised multispectral brain segmentation
    Alfano, B
    Quarantelli, M
    Brunetti, A
    Larobina, M
    Covelli, EM
    Tedeschi, E
    Salvatore, M
    MAGNETIC RESONANCE IN MEDICINE, 1998, 39 (03) : 497 - 499
  • [2] Brain tumor volume measurement: Comparison of manual and semiautomated methods
    Joe, BN
    Fukui, MB
    Meltzer, CC
    Huang, QS
    Day, RS
    Greer, PJ
    Bozik, ME
    RADIOLOGY, 1999, 212 (03) : 811 - 816
  • [3] Validity and reliability of computerized measurement of lumbar intervertebral disc height and volume from magnetic resonance images
    Neubert, Ales
    Fripp, Jurgen
    Engstrom, Craig
    Gal, Yaniv
    Crozier, Stuart
    Kingsley, Michael I. C.
    SPINE JOURNAL, 2014, 14 (11) : 2773 - 2781
  • [4] Validation study of a fast, accurate, and precise brain tumor volume measurement
    Dang, Mong
    Modi, Jayesh
    Roberts, Mike
    Chan, Christopher
    Mitchell, J. Ross
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2013, 111 (02) : 480 - 487
  • [5] Automated measurement of brain and white matter lesion volume in type 2 diabetes mellitus
    C. Jongen
    J. van der Grond
    L. J. Kappelle
    G. J. Biessels
    M. A. Viergever
    J. P. W. Pluim
    Diabetologia, 2007, 50 : 1509 - 1516
  • [6] Automated measurement of brain and white matter lesion volume in type 2 diabetes mellitus
    Jongen, C.
    van der Grond, J.
    Kappelle, L. J.
    Biessels, G. J.
    Viergever, M. A.
    Pluim, J. P. W.
    DIABETOLOGIA, 2007, 50 (07) : 1509 - 1516
  • [7] Longitudinal MR study of brain structure and hippocampus volume in major depressive disorder
    Ahdidan, J.
    Hviid, L. B.
    Chakravarty, M. M.
    Ravnkilde, B.
    Rosenberg, R.
    Rodell, A.
    Stodkilde-Jorgensen, H.
    Videbech, P.
    ACTA PSYCHIATRICA SCANDINAVICA, 2011, 123 (03) : 211 - 219
  • [8] VENTRICLES OF BRAIN: A MORPHOMETRIC STUDY BY COMPUTERIZED TOMOGRAPHY
    Singh, Brij Raj
    Gajbe, Ujwal
    Agrawal, Amit
    Reddy, Anilkumar Y.
    Bhartiya, Sunita
    INTERNATIONAL JOURNAL OF MEDICAL RESEARCH & HEALTH SCIENCES, 2014, 3 (02): : 381 - 387
  • [9] BRAIN-TISSUE VOLUME MEASUREMENT FROM MAGNETIC-RESONANCE-IMAGING - A PHANTOM STUDY
    RUSINEK, H
    CHANDRA, R
    INVESTIGATIVE RADIOLOGY, 1993, 28 (10) : 890 - 895
  • [10] MEASUREMENT OF TUMOR RESECTION VOLUMES FROM COMPUTERIZED IMAGES
    DUONG, DH
    ROSTOMILY, RC
    HAYNOR, DR
    KELES, GE
    BERGER, MS
    JOURNAL OF NEUROSURGERY, 1992, 77 (01) : 151 - 154