Comparison of transient ischemic dilation ratios in SPECT and SPECT-CT myocardial perfusion imaging in the low pre-test probability group

被引:0
作者
Fallahi, Babak [1 ]
Fard-Esfahani, Armaghan [1 ]
Hassanzadeh-Rad, Arman [1 ]
Emami-Ardekani, Alireza [1 ]
Beiki, Davood [1 ]
Eftekhari, Mohammad [1 ]
机构
[1] Univ Tehran Med Sci, Res Ctr Nucl Med, Tehran, Iran
来源
IRANIAN JOURNAL OF NUCLEAR MEDICINE | 2014年 / 22卷 / 02期
关键词
Transient ischemic dilation; Myocardial perfusion imaging; Attenuation correction; SPECT-CT;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
: The main purpose of this study was to compare transient ischemic dilation (TID) ratios in SPECT-low dose CT and SPECT Myocardial Perfusion Imaging (MPI) by application of different quantitative programs and quantify the possible shift in the upper normal limits of TID ratio in the SPECT-CT MPI. Methods: 149 Patients with low pre-test probability for coronary artery disease (CAD), based upon Diamond and Forrester method entered the study. Each patient underwent both attenuation correction (AC) SPECT-CT MPI and non attenuation correction (NAC) SPECT MPI (two day Tc-99m sestamibi stress-rest protocol). Normalcy rates were also calculated and compared. The comparison was based on both visual interpretation and quantitative analysis. Results: In the low pre-test probability group visual interpretations lead to a statistically significant improvement in normalcy rate in the SPECT-CT acquisition compared to the SPECT MPI. Regardless of the stress type and software programs used, no significant difference was noted in the upper normal limits of the TID ratios between the AC and NAC acquisitions. Conclusion: The study showed superiority of SPECT-CT MPI to SPECT MPI in terms of normalcy rate. We also propose new upper normal limits of TID ratios for different sets of acquisition-gender-stress modality-software programs.
引用
收藏
页码:51 / 56
页数:6
相关论文
共 17 条
[1]   Transient ischemic dilation ratio of the left ventricle is a significant predictor of future cardiac events in patients with otherwise normal myocardial perfusion SPECT [J].
Abidov, A ;
Bax, JJ ;
Hayes, SW ;
Hachamovitch, R ;
Cohen, I ;
Gerlach, J ;
Kang, XP ;
Friedman, JD ;
Germano, G ;
Berman, DS .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2003, 42 (10) :1818-1825
[2]  
Araujo LI, 2000, J NUCL MED, V41, P1139
[3]   Influence of Attenuation Correction on Transient Left Ventricular Dilation in Dual Isotope Myocardial Perfusion Imaging in Patients With Known or Suspected Coronary Artery Disease [J].
Brodov, Yafim ;
Frenkel, Alex ;
Chouraqui, Pierre ;
Przewloka, Kinga ;
Rispler, Shmuel ;
Abadi, Sobhi ;
Keidar, Zohar .
AMERICAN JOURNAL OF CARDIOLOGY, 2012, 110 (01) :57-61
[4]   Attenuation correction for single photon emission computed tomography myocardial perfusion imaging [J].
Corbett J.R. ;
Kritzman J.N. ;
Ficaro E.P. .
Current Cardiology Reports, 2004, 6 (1) :32-40
[5]  
Corbett JR, 2008, J NUCL MED S1, V49
[6]   ANALYSIS OF PROBABILITY AS AN AID IN THE CLINICAL-DIAGNOSIS OF CORONARY-ARTERY DISEASE [J].
DIAMOND, GA ;
FORRESTER, JS .
NEW ENGLAND JOURNAL OF MEDICINE, 1979, 300 (24) :1350-1358
[7]  
Fricke E, 2005, J NUCL MED, V46, P736
[8]   Quantitative single-photon emission computed tomography imaging [J].
Germano G. ;
Berman D.S. .
Current Cardiology Reports, 2005, 7 (2) :136-142
[9]   The value and practice of attenuation correction for myocardial perfusion SPECT imaging: A joint position statement from the American Society of Nuclear Cardiology and the Society of Nuclear Medicine [J].
Hendel, RC ;
Corbett, JR ;
Cullom, SJ ;
DePuey, EG ;
Garcia, EV ;
Bateman, TM .
JOURNAL OF NUCLEAR CARDIOLOGY, 2002, 9 (01) :135-143
[10]   Assessment of transient left ventricular dilation ratio via 2-day dipyridamole Tc-99m sestamibi nongated myocardial perfusion imaging [J].
Kakhki, Vahid Reza Dabbagh ;
Sadeghi, Ramin ;
Zakavi, Seyed Rasoul .
JOURNAL OF NUCLEAR CARDIOLOGY, 2007, 14 (04) :529-536