Performance evaluation of two types of heated cables for distributed temperature sensing-based measurement of soil moisture content

被引:18
作者
Cao, Dingfeng [1 ]
Shi, Bin [1 ]
Zhu, Honghu [1 ]
Zhu, Kun [1 ]
Wei, Guangqing [2 ]
Gu, Kai [1 ]
机构
[1] Nanjing Univ, Sch Earth Sci & Engn, 163 Xianlin Avenu, Nanjing 210023, Jiangsu, Peoples R China
[2] Suzhou NanZee Sensing Technol Co Ltd, Suzhou 215123, Peoples R China
基金
中国国家自然科学基金;
关键词
Soil moisture content; Carbon-fiber heated cable (CFHC); Metal-net heated cable (MNHC); Distributed measurement; Optical fiber;
D O I
10.1016/j.jrmge.2015.09.005
中图分类号
P5 [地质学];
学科分类号
0709 ; 081803 ;
摘要
Distributed temperature sensing (DTS) using heated cables has been recently developed for distributed monitoring of in-situ soil moisture content. In this method, the thermal and electrical properties of heated cables have a significant influence on the measurement accuracy of soil moisture content. In this paper, the performances of two heated cables, i.e. the carbon-fiber heated cable (CFHC) and the metal-net heated cable (MNHC), are studied in the laboratory. Their structures, uniformity in the axial direction, measurement accuracy and suitability are evaluated. The test results indicate that the MNHC has a better uniformity in the axial direction than CFHC. Both CFHC and MNHC have high measurement accuracy. The CFHC is more suitable for short-distance measurement (<= 500 m), while the MNHC can be used for longdistance measurement (> 500 m). (C) 2016 Institute of Rock and Soil Mechanics, Chinese Academy of Sciences. Production and hosting by Elsevier B. V. All rights reserved.
引用
收藏
页码:212 / 217
页数:6
相关论文
共 17 条
[1]   An Experimental Study on the Effective Parameters of Thermal Conductivity of Mine Backfill [J].
Abbasy, Farzaan ;
Hassani, Ferri P. ;
Madiseh, Seyed Ali Ghoreishi ;
Cote, Jean ;
Nokken, Michelle R. .
HEAT TRANSFER ENGINEERING, 2014, 35 (13) :1209-1224
[2]   Soil thermal conductivity: Effects of density, moisture, salt concentration, and organic matter [J].
Abu-Hamdeh, NH ;
Reeder, RC .
SOIL SCIENCE SOCIETY OF AMERICA JOURNAL, 2000, 64 (04) :1285-1290
[3]  
[曹鼎峰 Cao Dingfeng], 2014, [岩土工程学报, Chinese Journal of Geotechnical Engineering], V36, P910
[4]  
CARSLAW HS, 1959, CONDUCTION HEAT SOLI
[5]   Heated Optical Fiber for Distributed Soil-Moisture Measurements: A Lysimeter Experiment [J].
Ciocca, Francesco ;
Lunati, Ivan ;
Van de Giesen, Nick ;
Parlange, Marc B. .
VADOSE ZONE JOURNAL, 2012, 11 (04)
[6]  
Cote A., 2009, P 7 INT S FIELD MEAS, P1
[7]   Fiber optic sensor technology: an overview [J].
Grattan, KTV ;
Sun, T .
SENSORS AND ACTUATORS A-PHYSICAL, 2000, 82 (1-3) :40-61
[8]   High-resolution temperature observations to monitor soil thermal properties as a proxy for soil moisture condition in clay-shale landslide [J].
Krzeminska, Dominika M. ;
Steele-Dunne, Susan C. ;
Bogaard, Thom A. ;
Rutten, Martine M. ;
Sailhac, Pascal ;
Geraud, Yves .
HYDROLOGICAL PROCESSES, 2012, 26 (14) :2143-2156
[9]  
Lin YL, 2002, OPTOELECTRONIC TECHN, V15, P33
[10]   Characterizing the two-dimensional thermal conductivity distribution in a sand and gravel aquifer [J].
Markle, Jeff M. ;
Schincariol, Robert A. ;
Sass, John H. ;
Molson, John W. .
SOIL SCIENCE SOCIETY OF AMERICA JOURNAL, 2006, 70 (04) :1281-1294