DETECTION OF SURFACE-ACTIVITY BY VOLTAMMETRIC MEASUREMENTS

被引:6
作者
KOMORSKYLOVRIC, S
LOVRIC, M
BRANICA, M
机构
[1] Center for Marine Research Zagreb, 'rudjer Boškovic' Institute, Zagreb, 41001
关键词
SURFACE ACTIVITY; SURFACTANT; ADSORPTION; TRITON X-100; CADMIUM;
D O I
10.1002/elan.1140070710
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Influences of a nonionic detergent Triton X-100 on square-wave voltammetry and anodic stripping square-wave voltammetry of Cd2+ in 0.5 M NaClO4 + 0.01 M HClO4 are measured at precisely controlled durations of adsorptive accumulation and surfactant concentrations. Diagnostic criteria for the presence of surface-active substances in electrolytes are reported. A voltammetric method for the quantitative analysis of detergents is proposed. An ionic type of detergent can be recognized by the variation of the accumulation potential.
引用
收藏
页码:652 / 655
页数:4
相关论文
共 50 条
[41]   Evaluation of cadmium-metallothionein stability constants based on voltammetric measurements [J].
Erk, M ;
Raspor, B .
ANALYTICA CHIMICA ACTA, 1998, 360 (1-3) :189-194
[42]   Surface and Antimicrobial Activity of Sulfobetaines [J].
Wieczorek, Daria ;
Gwiazdowska, Daniela ;
Staszak, Katarzyna ;
Chen, Ying-Lien ;
Shen, Tang-Long .
JOURNAL OF SURFACTANTS AND DETERGENTS, 2016, 19 (04) :813-822
[43]   Chiral detection by induced surface-enhanced Raman optical activity [J].
Das, Moumita ;
Gangopadhyay, Debraj ;
Sebestik, Jaroslav ;
Habartova, Lucie ;
Michal, Pavel ;
Kapitan, Josef ;
Bour, Petr .
CHEMICAL COMMUNICATIONS, 2021, 57 (52) :6388-6391
[44]   Voltammetric Behavior of Semicarbazide at Graphene Modified Electrode and Application to Detection [J].
Zhang, Xuzhi ;
Gu, Xiaolei ;
Qu, Keming ;
Zhao, Changzhi .
JOURNAL OF THE CHINESE CHEMICAL SOCIETY, 2014, 61 (06) :687-694
[45]   Voltammetric detection of Neuropeptide Y using a modified sawhorse waveform [J].
Alyamni, Nadiah ;
Abot, Jandro L. ;
Zestos, Alexander G. .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2024, 416 (21) :4807-4818
[46]   Voltammetric detection of arsenic on a bismuth modified exfoliated graphite electrode [J].
Ndlovu, Thabile ;
Mamba, Bhelde B. ;
Sampath, Srinivasan ;
Krause, Rui W. ;
Arotiba, Omotayo A. .
ELECTROCHIMICA ACTA, 2014, 128 :48-53
[47]   Interpretation of speciation measurements on labile metal-macromolecular systems by voltammetric techniques [J].
Garces, JL ;
Mas, F ;
Cecilia, J ;
Galceran, J ;
Salvador, J ;
Puy, J .
ANALYST, 1996, 121 (12) :1855-1861
[48]   Rapid Microarray Detection of DNA and Proteins in Microliter Volumes with Surface Plasmon Resonance Imaging Measurements [J].
Seefeld, Ting Hu ;
Zhou, Wen-Juan ;
Corn, Robert M. .
LANGMUIR, 2011, 27 (10) :6534-6540
[49]   Stripping voltammetric detection of cadmium in small volume samples based on the magnetohydrodynamics [J].
Cao Xiao-Hua ;
Liu, Yang ;
Wei Wan-Zhi ;
Gao Yan-Ping .
CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2008, 36 (03) :397-400
[50]   Voltammetric Detection of Lead Using Chitosan-tripolyphosphate Crosslinked Electrode [J].
Heineman, Monika G. ;
Goncalves, Bruna L. ;
Vicenti, Juliano R. M. ;
Dias, Daiane .
ANALYTICAL SCIENCES, 2019, 35 (11) :1255-1261