COMPARISON OF FAST-ATOM-BOMBARDMENT MASS-SPECTROMETRY AND SIZE-EXCLUSION CHROMATOGRAPHY IN DEFINING HIGH-MOLECULAR MASSES IN COAL-DERIVED MATERIALS

被引:20
作者
HEROD, AA
STOKES, BJ
TYE, RE
GAINES, AF
LI, CZ
KANDIYOTI, R
机构
[1] UNIV LONDON IMPERIAL COLL SCI TECHNOL & MED,IMPERIAL COLL SCI TECHNOL & MED,LONDON SW7 2BY,ENGLAND
[2] BRITISH COAL CORP,COAL RES ESTAB,CHELTENHAM GL52 4RZ,GLOS,ENGLAND
[3] UNIV LONDON KINGS COLL,DEPT CHEM,LONDON WC2R 2LS,ENGLAND
关键词
COAL DERIVATIVES; CHROMATOGRAPHY; MASS SPECTROMETRY;
D O I
10.1016/0016-2361(93)90131-K
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The detection by fast atom bombardment mass spectrometry (f.a.b.-m.s.) of high molecular mass (greater than 1000 Da) material in coal-derived products was investigated. The pentane insoluble (PI) fractions of liquefaction extracts from maceral concentrates of two UK coals (Linby and Cortonwood), prepared in a low-residence time (less than 10s) flowing-solvent reactor and fractions of hydropyrolysis tar prepared in a hot-rod reactor at 500-degrees-C were examined. F.a.b.-m.s. spectra of the Cortonwood liptinite concentrate liquefaction extract PI-fraction mounted in a thiodiethanol matrix indicated ions up to molecular masses of about 4000 Da. This appears to be the highest reported molecular mass identified by fast atom bombardment in a coal-derived material. Other liquefaction extract PI-fractions showed somewhat lower molecular masses. The phenolic, basic nitrogen and aromatic fractions of the hydropyrolysis tar indicated ionization up to molecular mass limits between 1500 and 2000 Da. Comparison of these results with size exclusion chromatography (s.e.c.) showed agreement with results for the hydropyrolysis tar fractions; however, the presence of molecular masses in excess of 10 000 Da was indicated by s.e.c. for the liquefaction extract PI-fractions. Not all problems associated with vaporization, ionization and detection of high molecular mass materials in f.a.b.-m.s. appear to have been solved, with the choice (polarity) and preparation of matrices for sample mounting remaining an empirical procedure.
引用
收藏
页码:1317 / 1325
页数:9
相关论文
共 38 条
  • [1] EVAPORATIVE ANALYZER AS A MASS DETECTOR IN THE SIZE-EXCLUSION CHROMATOGRAPHY OF COAL EXTRACTS
    BARTLE, KD
    TAYLOR, N
    MULLIGAN, MJ
    MILLS, DG
    GIBSON, C
    [J]. FUEL, 1983, 62 (10) : 1181 - 1185
  • [2] MOLECULAR MASS CALIBRATION IN SIZE-EXCLUSION CHROMATOGRAPHY OF COAL DERIVATIVES
    BARTLE, KD
    MULLIGAN, MJ
    TAYLOR, N
    MARTIN, TG
    SNAPE, CE
    [J]. FUEL, 1984, 63 (11) : 1556 - 1560
  • [3] BARTLE KD, 1986, ANAL CHEM, V58, P2404
  • [4] CONTINUOUS-FLOW SAMPLE PROBE FOR FAST-ATOM-BOMBARDMENT MASS-SPECTROMETRY
    CAPRIOLI, RM
    FAN, T
    COTTRELL, JS
    [J]. ANALYTICAL CHEMISTRY, 1986, 58 (14) : 2949 - 2954
  • [5] CAPRIOLI RM, 1985, MASS SPECTROMETRY, V8, pCH8
  • [6] DASS C, 1990, J AM SOC MASS SPECTR, V1, P397
  • [7] COMPARISON OF MASS-SPECTRAL TECHNIQUES USING ORGANIC PEROXIDES RELATED TO ARTEMISININ
    FALES, HM
    SOKOLOSKI, EA
    PANNELL, LK
    PU, QL
    KLAYMAN, DL
    LIN, AJ
    BROSSI, A
    KELLEY, JA
    [J]. ANALYTICAL CHEMISTRY, 1990, 62 (22) : 2494 - 2501
  • [8] GAINES AF, 1991, P INT C COAL SCI NEW, P830
  • [9] A FLOWING SOLVENT REACTOR FOR COAL-LIQUEFACTION WITH DIRECT ELECTRICAL-RESISTANCE HEATING
    GIBBINS, J
    KANDIYOTI, R
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1991, 62 (09) : 2234 - 2242
  • [10] PYROLYSIS AND HYDROPYROLYSIS OF COAL - COMPARISON OF PRODUCT DISTRIBUTIONS FROM A WIRE-MESH AND A HOT-ROD REACTOR
    GIBBINS, JR
    GONENC, ZS
    KANDIYOTI, R
    [J]. FUEL, 1991, 70 (05) : 621 - 626