Variability in measurement of acetabular index

被引:1
作者
Ibanez L, Angelica [1 ]
Ramirez M, Constanza [2 ]
Hodgson O, Felipe [1 ]
Valenzuela V, Joaquin [2 ]
Karzulovic B, Lorena [3 ]
Llanos C, Jorge [4 ]
Izquierdo P, Guillermo [5 ]
Valdes S, Macarena [6 ]
机构
[1] Pontificia Univ Catolica Chile, Traumatol, Dept Traumatol & Ortopedia, Santiago, Chile
[2] Pontificia Univ Catolica Chile, Traumatol & Ortopedia, Santiago, Chile
[3] Pontificia Univ Catolica Chile, Pediat, Santiago, Chile
[4] Pontificia Univ Catolica Chile, Dept Radiol, Santiago, Chile
[5] Pontificia Univ Catolica Chile, Interno Ano Med 7, Santiago, Chile
[6] Pontificia Univ Catolica Chile, Tecnol Med, Unidad Invest, Dept Traumatol & Ortopedia, Santiago, Chile
来源
REVISTA CHILENA DE PEDIATRIA-CHILE | 2013年 / 84卷 / 02期
关键词
Developmental dysplasia of the hip (DDH); acetabular index; intra-observer variability; inter-observer variability; radiography;
D O I
10.4067/S0370-41062013000200006
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Developmental dysplasia of the hip (DDH) is a spectrum of diseases ranging from frank dislocation of the hip to mild acetabular dysplasia. DDH screening for detection is performed routinely in our country using pelvic x-ray at 3 months of age. The radiographic measured acetabular index is used to evaluate the dysplastic hip. at initial presentation and during follow-up. Objective: Evaluation of the intra- and inter-observer variability, among medical professionals, when measuring acetabular index. Methods: Four reviewers (a children orthopedic surgeon, a general practitioner, a pediatrician and a radiologist) performed acetabular index measurement in 100 radiographs (200 hips), on three occasions, separated each by one month (600 total measurements). An independent observer evaluated the measurement reproducibility. The intra-class correlation coefficient to determine significant differences was used. Results: The intra-observer variability was less than the inter-observer variability. The intra-observer variability was similar among the different assessors, +/- 1.5 degrees. The inter-observer variability was +/- 3.4 degrees. Conclusions: A high concordance among measurements was reported, evidencing a high reproducibility of the acetabular index; this index is a reliable method for the diagnosis and follow-up of acetabular dysplasia.
引用
收藏
页码:160 / 165
页数:6
相关论文
共 15 条
[1]  
[Anonymous], 2010, GUIA CLIN DISPL LUX, P7
[2]  
Arce J, 2000, REV CHIL PEDIAT, V71
[3]   THE OPPOSITE HIP IN CONGENITAL DISLOCATION OF THE HIP [J].
BOLTONMAGGS, BG ;
CRABTREE, SD .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1983, 65 (03) :279-284
[4]   ULTRASOUND SCREENING FOR HIP-DYSPLASIA IN NEWBORNS [J].
HOLEN, KJ ;
TERJESEN, T ;
TEGNANDER, A ;
BREDLAND, T ;
SAETHER, OD ;
EIKNES, SH .
JOURNAL OF PEDIATRIC ORTHOPAEDICS, 1994, 14 (05) :667-673
[5]   Variability in the assessment of acetabular index [J].
Kay, RM ;
Watts, HG ;
Dorey, FJ .
JOURNAL OF PEDIATRIC ORTHOPAEDICS, 1997, 17 (02) :170-173
[6]   MEASUREMENT OF THE COBB ANGLE ON RADIOGRAPHS OF PATIENTS WHO HAVE SCOLIOSIS - EVALUATION OF INTRINSIC ERROR [J].
MORRISSY, RT ;
GOLDSMITH, GS ;
HALL, EC ;
KEHL, D ;
COWIE, GH .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1990, 72A (03) :320-327
[7]   The assessment of acetabular index - Is there still a place for plain radiography? [J].
Pirpiris, Marinis ;
Payman, K. Rad ;
Otsuka, Norman Y. .
JOURNAL OF PEDIATRIC ORTHOPAEDICS, 2006, 26 (03) :310-315
[8]  
Raimann A, 2003, ENFERMEDAD LUXANTE C, P19
[9]   Variability in measurement of acetabular index in normal and dysplastic hips, before and after reduction [J].
Skaggs, DL ;
Kaminsky, C ;
Tolo, VT ;
Kay, RM ;
Reynolds, RAK .
JOURNAL OF PEDIATRIC ORTHOPAEDICS, 1998, 18 (06) :799-801
[10]   Measurement of acetabular index intraobserver and interobserver variation [J].
Spatz, DK ;
Reiger, M ;
Klaumann, M ;
Miller, F ;
Stanton, RP ;
Lipton, GE .
JOURNAL OF PEDIATRIC ORTHOPAEDICS, 1997, 17 (02) :174-175